Search results for "Biomaterials"
showing 10 items of 1265 documents
Neutrophil‐mediated enhancement of angiogenesis and osteogenesis in a novel triple cell co‐culture model with endothelial cells and osteoblasts
2017
Repair and regeneration of critical‐sized bone defects remain a major challenge in orthopaedic and craniomaxillofacial surgery. Until now, attempts to bioengineer bone tissue have been hindered by the inability to establish proper angiogenesis and osteogenesis in the tissue construct. In the present study, we established a novel triple cell co‐culture model consisting of osteoblasts, endothelial cells, and neutrophils and conducted a systematic investigation of the effects of neutrophils on angiogenesis and osteogenesis. Neutrophils significantly increased angiogenesis in the tissue construct, evidenced by the formation of microvessel‐like structures with an extensive lattice‐like, stable t…
Cutaneous Recording and Stimulation of Muscles Using Organic Electronic Textiles
2016
International audience; Electronic textiles are an emerging field providing novel and non-intrusive solutions for healthcare. Conducting polymer-coated textiles enable a new generation of fully organic surface electrodes for electrophysiological evaluations. Textile electrodes are able to assess high quality muscular monitoring and to perform transcutaneous electrical stimulation.
Unfractionated Heparin Versus Subcutaneous Nadroparin in Adults Supported With Venovenous Extracorporeal Membrane Oxygenation: a Retrospective, Multi…
2021
Extracorporeal membrane oxygenation (ECMO) requires constant management of coagulation. Whereas unfractionated heparin remains the anticoagulant of choice, experienced centers report high bleeding rates. Biocompatibility of the extracorporeal circuit enables management of anticoagulation with subcutaneous low-molecular-weight heparins only. The aim of this study was to evaluate the safety and feasibility of anticoagulation with subcutaneous nadroparin compared with unfractionated heparin during respiratory ECMO in patients. We assessed for thrombotic complications and number of bleeding and life-threatening bleeding events. Additionally, we evaluated the change in resistance to flow in the …
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Biomechanical Determinants of Right Ventricular Failure in Pulmonary Hypertension.
2018
Pulmonary hypertension (PH) is a disease characterized by progressive adverse remodeling of the distal pulmonary arteries, resulting in elevated pulmonary vascular resistance and load pressure on the right ventricle (RV), ultimately leading to RV failure. Invasive hemodynamic testing is the gold standard for diagnosing PH and guiding patient therapy. We hypothesized that lumped-parameter and biventricular finite-element (FE) modeling may lead to noninvasive predictions of both PH-related hemodynamic and biomechanical parameters that induce PH. We created patient-specific biventricular FE models that characterize the biomechanical response of the heart and coupled them with a lumped-paramete…
Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness
2013
Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…
Bone Marrow Concentrate and Bovine Bone Mineral for Sinus Floor Augmentation
2011
Purpose: The purpose of this work was to evaluate the potential of substituting autogenous bone (AB) by bone marrow aspirate concentrate (BMAC). Both AB and BMAC were tested in combination with a bovine bone mineral (BBM) for their ability of new bone formation (NBF) in a multicentric, randomized, controlled, clinical and histological noninferiority trial.Materials and Methods: Forty-five severely atrophied maxillary sinus from 26 patients were evaluated in a partial cross-over design. As test arm, 34 sinus of 25 patients were augmented with BBM and BMAC containing mesenchymal stem cells. Eleven control sinus from 11 patients were augmented with a mixture of 70% BBM and 30% AB. Biopsies wer…
Epidemiology of hepatitis C virus infection in hemodialysis patients of Sicily
2008
Which muscles compromise human locomotor performance with age?
2014
Ageing leads to a progressive decline in human locomotor performance. However, it is not known whether this decline results from reduced joint moment and power generation of all lower limb muscle groups or just some of them. To further our understanding of age-related locomotor decline, we compare the amounts of joint moments and powers generated by lower limb muscles during walking (self-selected), running (4 m s −1 ) and sprinting (maximal speed) among young, middle-aged and old adults. We find that age-related deficit in ankle plantarflexor moment and power generation becomes more severe as locomotion change from walking to running to sprinting. As a result, old adults generate more pow…
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…