Performance of a new device for the clinical determination of light discomfort

2020

PURPOSE To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Repeated measures ANOVA, Kruskal-Wallis, and correlation analysis were applied to test for differences between repeated measures, and effect of age on reliability. RESULTS Discomfort thresholds obtained are well distributed across the light intensity…

AdultMalemedicine.medical_specialtyLightIntraclass correlationCoefficient of variationBiomedical Engineering030204 cardiovascular system & hematologyAudiologyStandard deviationYoung Adult03 medical and health sciences0302 clinical medicineHumansMedicineReliability (statistics)AgedReproducibilitybusiness.industryReproducibility of ResultsRepeated measures designGeneral MedicineRepeatabilityMiddle AgedLight intensityFemaleSurgerybusiness030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness

2013

Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…

AdultMalemedicine.medical_specialtyMaterials scienceOptical PhenomenaCoefficient of variationBiomedical EngineeringBlood PressureDerivativePulse Wave AnalysisSignalBiomaterialsYoung AdultVascular StiffnessPhotoplethysmogramPressuremedicineHumansPulse wavePhotoplethysmographyBlood VolumePulse (signal processing)Optical DevicesRepeatabilityAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryTransducerFemaleBiomedical engineeringJournal of Biomedical Optics
researchProduct

Cerebrovascular and cardiovascular variability interactions investigated through conditional joint transfer entropy in subjects prone to postural syn…

2017

Objective: A model-based conditional transfer entropy approach was exploited to quantify the information transfer in cerebrovascular (CBV) and cardiovascular (CV) systems in subjects prone to develop postural syncope. Approach: Spontaneous beat-to-beat variations of mean cerebral blood flow velocity (MCBFV) derived from a transcranial Doppler device, heart period (HP) derived from surface electrocardiogram, mean arterial pressure (MAP) and systolic arterial pressure (SAP) derived from finger plethysmographic arterial pressure device were monitored at rest in supine position (REST) and during 60° head-up tilt (TILT) in 13 individuals (age mean ± standard deviation: 28 ± 9 years, min-max r…

AdultMalemedicine.medical_specialtyMean arterial pressureSupine positioncerebral autoregulationAdolescentPhysiologyUltrasonography Doppler TranscranialEntropyBiomedical EngineeringBiophysics030204 cardiovascular system & hematologyBaroreflexCerebral autoregulationSyncope03 medical and health sciencesElectrocardiographyYoung Adult0302 clinical medicinehead-up tiltHeart RatePhysiology (medical)Internal medicineinformation transfermedicineHeart rate variabilityHumansbaroreflexArterial Pressurebusiness.industryautonomic nervous systemheart rate variabilitySignal Processing Computer-AssistedTranscranial DopplerPlethysmographyBlood pressureBiophysicCerebral blood flowpostural syncopeAnesthesiaCerebrovascular CirculationSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyFemaleDisease Susceptibilitybusiness030217 neurology & neurosurgeryHumanPhysiological measurement
researchProduct

Contributions of individual muscles to the sagittal- and frontal-plane angular accelerations of the trunk in walking.

2013

This study was conducted to analyze the unimpaired control of the trunk during walking. Studying the unimpaired control of the trunk reveals characteristics of good control. These characteristics can be pursued in the rehabilitation of impaired control. Impaired control of the trunk during walking is associated with aging and many movement disorders. This is a concern as it is considered to increase fall risk. Muscles that contribute to the trunk control in normal walking may also contribute to it under perturbation circumstances, attempting to prevent an impending fall. Knowledge of such muscles can be used to rehabilitate impaired control of the trunk. Here, angular accelerations of the t…

AdultMalemedicine.medical_specialtyMovement disordersAdolescentAccelerationBiomedical EngineeringBiophysicsPoison controlWalkingYoung AdultPhysical medicine and rehabilitationImaging Three-DimensionalmedicineHumansOrthopedics and Sports MedicineComputer Simulationta315ChildMuscle SkeletalGaitta114biologybusiness.industryRehabilitationHealthy subjectsFall riskbiology.organism_classificationTrunkSagittal planeHealthy VolunteersMediusmedicine.anatomical_structureLower ExtremityCoronal planePhysical therapyFemalemedicine.symptombusinesshuman activitiesSoftwareGravitationJournal of biomechanics
researchProduct

Isometric parameters in the monitoring of maximal strength, power, and hypertrophic resistance-training.

2017

This study monitored strength-training adaptations via isometric parameters throughout 2 × 10 weeks of hypertrophic (HYP I–II) or 10 weeks maximum strength (MS) followed by 10 weeks power (P) training with untrained controls. Trainees performed bilateral isometric leg press tests analyzed for peak force (maximal voluntary contraction (MVC)) and rate of force development (RFD) every 3.5 weeks. These parameters were compared with dynamic performance, voluntary and electrically induced isometric contractions, muscle activity, and cross-sectional area (CSA) in the laboratory before and after 10 and 20 weeks. RFD increased similarly during the first 7 weeks (HYP I, 44% ± 53%; MS, 48% ± 55%, P &l…

AdultMalemedicine.medical_specialtyPhysiologyStrength trainingEndocrinology Diabetes and MetabolismIsometric exercise030204 cardiovascular system & hematology03 medical and health sciencesYoung Adult0302 clinical medicinePhysiology (medical)Isometric ContractionMaximal strengthmedicineHumansMuscle StrengthMuscle SkeletalNutrition and Dieteticsbusiness.industryResistance trainingResistance Training030229 sport sciencesGeneral MedicineHypertrophyAdaptation PhysiologicalPower (physics)AthletesPhysical therapyExercise TestbusinessBiomedical engineeringMuscle ContractionApplied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme
researchProduct

Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: a randomized controlled histologic study

2016

Introduction Plasma application can lead to an improved adhesion between soft tissue and abutments and promotes cell spreading. Objective A triple-blinded randomized controlled clinical trial was performed to in vivo test the effect of cleaning abutment titanium surfaces with plasma of argon on cell adhesion and collagen fiber orientation at an early healing time. Material and methods Thirty healthy patients with 30 submerged implants, at the second surgery, randomly received either a specially designed abutment with no additional treatment (as they come from industry; control group, G1) or cleaned by plasma of argon (test group, G2). Two weeks thereafter, a small biopsy including abutment …

AdultMalemedicine.medical_specialtyPlasma GasesPlasma cleaninghistologic analysisGingivaAbutmentStatistical differenceDental Abutments02 engineering and technology03 medical and health sciences0302 clinical medicineDouble-Blind MethodBiopsyCell Adhesionmedicineplasma of argonHumansArgonCell adhesionperi-implant soft tissue responseAgedscanning electronic microscopemedicine.diagnostic_testdental abutment histologic analysis peri-implant soft tissue response plasma of argon scanning electronic microscopeChemistrySoft tissue030206 dentistryMiddle Aged021001 nanoscience & nanotechnologySurgeryDental Prosthesis DesignHomogeneousCoronal planedental abutmentFemaleOral Surgery0210 nano-technologyBiomedical engineeringClinical Oral Implants Research
researchProduct

3D characterisation of the dynamics of foot joints of adults during walking. Gait pattern identification

2017

A detailed description of the kinematics and kinetics of the ankle, midtarsal and metatarsophalangeal joints of the feet of a healthy adult male population during barefoot walking is provided. Plots of the angles and moments in each plane during the stance phase are reported, along with the mean and standard deviation values of 87 different parameters that characterise the 3D dynamics of the foot joints. These parameters were used to check for similarities between subjects through a hierarchical analysis that allowed three different gait patterns to be identified, most of the differences corresponding to the frontal and transverse planes.

AdultMalemedicine.medical_specialtyPopulationBiomedical EngineeringMetatarsophalangeal jointsBioengineeringKinematicsStandard deviation03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationImaging Three-DimensionalFiducial MarkersFoot JointsmedicineCluster AnalysisHumansgait patternseducationGaitMathematicseducation.field_of_studyDynamics (mechanics)030229 sport sciencesGeneral MedicineAnatomydynamicsfoot jointsGaitComputer Science ApplicationsBiomechanical PhenomenaHuman-Computer InteractionTransverse planemedicine.anatomical_structurekinematicskineticsAnkle030217 neurology & neurosurgery
researchProduct

Bone Marrow Concentrate and Bovine Bone Mineral for Sinus Floor Augmentation

2011

Purpose: The purpose of this work was to evaluate the potential of substituting autogenous bone (AB) by bone marrow aspirate concentrate (BMAC). Both AB and BMAC were tested in combination with a bovine bone mineral (BBM) for their ability of new bone formation (NBF) in a multicentric, randomized, controlled, clinical and histological noninferiority trial.Materials and Methods: Forty-five severely atrophied maxillary sinus from 26 patients were evaluated in a partial cross-over design. As test arm, 34 sinus of 25 patients were augmented with BBM and BMAC containing mesenchymal stem cells. Eleven control sinus from 11 patients were augmented with a mixture of 70% BBM and 30% AB. Biopsies wer…

AdultMalemedicine.medical_specialtySinus Floor AugmentationOSTEOGENIC DIFFERENTIATIONBone RegenerationMaxillary sinusBiomedical EngineeringSinus Floor AugmentationBioengineeringBiochemistryMAXILLARY SINUSlaw.inventionMESENCHYMAL STEM-CELLSBIO-OSSBiomaterialsRandomized controlled trialTISSUE-ENGINEERED BONEBone MarrowOsteogenesislawmedicineAnimalsHumansSingle-Blind MethodSinus (anatomy)AgedIMPLANT PLACEMENTHYDROXYAPATITE CERAMICSBone TransplantationIntention-to-treat analysisPOROUS HYDROXYAPATITEbusiness.industryIN-VITROMiddle AgedSurgeryAUTOGENOUS BONEImplant placementBovine bonemedicine.anatomical_structureBone SubstitutesCattleFemaleBone marrowbusinessTissue Engineering. Part A
researchProduct

Causal cross-spectral analysis of heart rate and blood pressure variability for describing the impairment of the cardiovascular control in neurally m…

2006

A causal approach to the calculation of coherence and transfer function between systolic pressure (SP) and RR interval variability was applied in eight patients and eight control subjects during prolonged tilt test for investigating the impairment of cardiovascular control related to neurally mediated syncope. The causal analysis showed a depressed baroreflex regulation in resting patients, with reduced gain and increased latency from SP to RR, and a drop of the baroreflex coupling immediately before syncope. These findings, which were not elicited by traditional cross-spectral analysis, strongly suggest the use of the causal approach for the study of syncope mechanisms. © 2006 IEEE.

AdultMalemedicine.medical_specialtyStatistics as TopicBiomedical EngineeringBlood PressureNeurally-mediated syncopeCardiovascular controlBaroreflexCardiovascular SystemSensitivity and SpecificitySeverity of Illness IndexFeedbackElectrocardiographyHeart RateInternal medicineSeverity of illnessHeart rateSyncope VasovagalmedicineHumansComputer SimulationDiagnosis Computer-AssistedModels Statisticalmedicine.diagnostic_testbusiness.industryTransfer functionModels CardiovascularReproducibility of ResultsBaroreflexBlood pressureData Interpretation StatisticalAnesthesiaCardiologyRegression AnalysisFemalebusinessElectrocardiographyCoherenceAlgorithmsSyncope (phonology)
researchProduct

Rapid Musculoskeletal Magnetic Resonance Imaging Using Integrated Parallel Acquisition Techniques (IPAT) - Initial Experiences

2003

Purpose To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T (2)-weighted TSE with and w…

AdultMalemedicine.medical_specialtyTime FactorsAdolescentImage qualityKnee InjuriesSensitivity and SpecificityFractures BoneMusculoskeletal disordermedicineHumansRadiology Nuclear Medicine and imagingDetection theoryAnkle InjuriesChildAgedSensitivity encodingAged 80 and overMusculoskeletal imagingmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFemoral Neck FracturesSurgerymedicine.anatomical_structureElectromagnetic coilFeasibility StudiesFemaleAnklebusinessAlgorithmsHip InjuriesBiomedical engineeringRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct