Search results for "Blood Circulation"
showing 10 items of 27 documents
Biodegradable Protein Nanocontainers
2015
The application of synthetic polymers for drug delivery often requires tremendous efforts to ensure biocompatibility and -degradation. To use the body's own substances can help to overcome these problems. Herein, we present the first synthesis of nanocontainers entirely composed of albumin proteins. These protein nanocontainers (PNCs) were loaded with hydrophilic compounds and release of the payload is triggered through natural lysis in vitro in human monocyte-derived dendritic cells (moDCs). No aggregation of PNCs in human blood plasma was observed, indicating stability for blood circulation. As the PNCs were readily taken up by moDCs, they are considered as a promising delivery platform f…
A model of stepwise isovolaemic blood exchange in anaesthetised, spontaneously breathing rats to evaluate the oxygen transport efficiency of artifici…
2000
Our research pursues the production of hypo-oncotic artificial oxygen carriers, based on artificial covalently cross-linked hyperpolymeric mammalian haemoglobins. To evaluate their in vivo efficiency in oxygen delivery to the tissue we developed a small animal model of stepwise isovolaemic blood exchange in anaesthetised, spontaneously breathing rats. With the aid of a two-way respiratory micro valve for small animals the overall oxygen uptake by the tissue of the animal can be determined. Measurements of oxygen contents in arterial and mixed venous blood and of some further blood parameters together with known oxygen-binding characteristics of artificial and native oxygen carriers, permits…
Stimulation of regional lymphatic and blood flow by epicutaneous oxazolone.
2002
The application of the epicutaneous antigen oxazolone results in persistent induration and erythema; however, the relative changes in lymph and blood flow in the inflammatory skin are largely unknown. To define the contribution of lymph and blood flow to the clinical appearance of cutaneous inflammation, we studied the sheep ear after the application of oxazolone. As a model for the study of these changes, the sheep ear had several experimental advantages: 1) a simplified superficial vascular network, 2) defined lymphatic drainage, and 3) an avascular and alymphatic cartilaginous barrier. Lymph flow was continuously monitored by cannulation of the prescapular efferent lymph duct. Blood flo…
Reproducibility of pulse wave velocity and augmentation index derived from non-invasive occlusive oscillometric tonometry analysis in adolescents
2018
The aim of this study was to investigate the short-term reproducibility of aortic pulse wave velocity (PWVao) and augmentation index (AIx%) assessed by the non-invasive oscillometric device. Altogether of 55 (19 boys, 36 girls) adolescents 16-19-years-of-age participated in the study. PWVao and AIx% were measured during the same laboratory visit at 2 min intervals using the Arteriograph™ device. Peak oxygen uptake (VO2peak ) was assessed by the maximal exercise test on a cycle ergometer and body fat percentage by bioelectrical impedance analysis. We studied reproducibility using intraclass correlation coefficients (ICC), coefficient variation with the root-means-square method expressed as p…
Blood pressure and pulse wave velocity values in the institutionalized elderly aged 80 and over: baseline of the PARTAGE study.
2009
The aim of the longitudinal study PARTAGE (predictive values of blood pressure and arterial stiffness in institutionalized very aged population) was to determine the predictive value of blood pressure (BP) and arterial stiffness for overall mortality, major cardiovascular events and cognitive decline in a large population of institutionalized patients aged 80 and over. In the study herein, we present the baseline data values of this study.A total of 1130 patients were recruited (878 women), living in French and Italian nursing homes. Clinical and 3-day self-measurements of BP were conducted. Aortic and upper limb pulse wave velocity were obtained using a PulsePen tonometer.Of this populatio…
Blood circulation of long bones in trained growing rats and mice
1975
The effect of physical training on the blood circulation of long bones was studied in growing rats and mice of NMRI-strain. The animals to be trained and their controls were about 2 weeks old at the beginning of the training. The training took place on a 5 degree inclined treadmill 5 days a week for 3 weeks in experiment I and 7 weeks in experiments II and III. The duration of the daily exercise was progressively increased over 3 weeks. The final exercise bouts were 80 min for moderate and 180 min for intensive training programs. The circulating red cell volume (ml/100 g bone) of the humeral, femoral and tibial bones of the trained animals was lower compared to the controls in all three exp…
Computational flow dynamics in a geometric model of intussusceptive angiogenesis.
2009
Intussusceptive angiogenesis is a process that forms new blood vessels by the intraluminal division of a single blood vessel into two lumens. Referred to as nonsprouting or intussusceptive angiogenesis, this angiogenic process has been described in morphogenesis and chronic inflammation. Mechanical forces are relevant to the structural changes associated with intussusceptive angiogenesis because of the growing evidence that physiologic forces influence gene transcription. To provide a detailed analysis of the spatial distribution of physiologic shear stresses, we developed a 3D finite element model of the intraluminal intussusceptive pillar. Based on geometries observed in adult intussuscep…
The effects of linearly increasing flip angles on 3D inflow MR angiography
1994
As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…
Sometimes Sperm Whales (Physeter macrocephalus) Cannot Find Their Way Back to the High Seas: A Multidisciplinary Study on a Mass Stranding
2011
BackgroundMass strandings of sperm whales (Physeter macrocephalus) remain peculiar and rather unexplained events, which rarely occur in the Mediterranean Sea. Solar cycles and related changes in the geomagnetic field, variations in water temperature and weather conditions, coast geographical features and human activities have been proposed as possible causes. In December 2009, a pod of seven male sperm whales stranded along the Adriatic coast of Southern Italy. This is the sixth instance from 1555 in this basin.Methodology/principal findingsComplete necropsies were performed on three whales whose bodies were in good condition, carrying out on sampled tissues histopathology, virology, bacter…
Use of photoplethysmography to determine gastrointestinal perfusion pressure: an experimental canine model.
2002
<i>Objectives:</i> To develop an experimental model to assess the parietal perfusion pressure (PPP) of the digestive tract using photoplethysmography. <i>Materials and Methods:</i> Twenty-two mongrel dogs were used. Progressive external compression was applied to the intestinal wall and the PPP was assessed with photoplethysmography. The study group was divided into two groups. In group 1 PPP was measured at the levels of the stomach, duodenum, jejunum and transverse colon. In group 2 PPP was measured after temporary occlusion of the truncal and marginal circulation of the jejunum to provide further variables. <i>Results:</i> The PPP decreased significant…