Search results for "Blood Volume"

showing 10 items of 63 documents

Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness

2013

Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…

AdultMalemedicine.medical_specialtyMaterials scienceOptical PhenomenaCoefficient of variationBiomedical EngineeringBlood PressureDerivativePulse Wave AnalysisSignalBiomaterialsYoung AdultVascular StiffnessPhotoplethysmogramPressuremedicineHumansPulse wavePhotoplethysmographyBlood VolumePulse (signal processing)Optical DevicesRepeatabilityAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryTransducerFemaleBiomedical engineeringJournal of Biomedical Optics
researchProduct

Comparison of intermittent- and continuous-flow cell separators for the collection of autologous peripheral blood progenitor cells in patients with h…

2001

BACKGROUND: The transplantation of autologous peripheral blood progenitor cells (PBPCs) after high-dose chemotherapy is a valuable therapy for patients with hematologic and solid malignancies. Several methods are used for harvesting PBPCs. The efficiency of intermittent- and continuous-flow blood cell separators in collecting progenitor cells from the blood of patients undergoing myeloablative treatment for cancer was compared. STUDY DESIGN AND METHODS: PBPC components (n = 133) were obtained from 72 patients by leukapheresis with continuous-flow machines (Spectra, COBE; CS 3000 Plus, Baxter) and with an intermittent-flow machine (MCS 3P, Haemonetics). The data were analyzed retrospectively…

AdultMalemedicine.medical_specialtymedicine.medical_treatmentImmunologyUrologyCD34Blood volumeAntigens CD34Cell SeparationTransplantation AutologousBlood cellmedicineImmunology and AllergyHumansPlateletLeukapheresisProgenitor cellRetrospective StudiesChemotherapybusiness.industryHematopoietic Stem Cell TransplantationHematologyLeukapheresisMiddle AgedHematopoietic Stem CellsSurgeryBlood Cell CountTransplantationmedicine.anatomical_structureHematologic NeoplasmsFemalebusinessTransfusion
researchProduct

Laparoscopic temporary clipping of uterine artery during laparoscopic myomectomy

2012

Purpose: Our aim is to study the feasibility and effect of bilateral laparoscopic temporary occlusion of uterine arteries by special vascular clamps on blood loss during laparoscopic myomectomy. Methods: Of 166 women with symptomatic uterine myomas necessitating surgical intervention who wished to retain their uteri, 80 underwent laparoscopic uterine artery clipping and myomectomy (experimental group) and 86 received laparoscopic myomectomy only (control group). Main outcome measures were operating time, number and weight of leiomyomas, blood loss, Doppler examination of the uterine arteries and complications of procedure. Results: In the experimental group the median hemoglobin drop measur…

Adultmedicine.medical_specialtyBlood loTime FactorsTime Factormedicine.medical_treatmentUterusBlood Loss SurgicalLaparoscopic myomectomyLaparoscopic temporary clipping of uterine arteryStatistics NonparametricBlood lossmedicine.arteryUterine MyomectomymedicineUterine NeoplasmHumansSymptomatic myomaUterine arteryLaparoscopyUterine NeoplasmUltrasonographyBlood VolumeChi-Square Distributionmedicine.diagnostic_testLeiomyomabusiness.industryLaparoscopic myomectomyUterusBlood lossObstetrics and GynecologyGeneral MedicineLaparoscopic myomectomy; Laparoscopic temporary clipping of uterine artery; Blood lossMiddle Agedmedicine.diseaseUterine myomectomyHemostasis SurgicalSurgeryUterine Arterymedicine.anatomical_structureLeiomyomaUteruUterine NeoplasmsFemaleLaparoscopybusinessHuman
researchProduct

Intravascular volume therapy in adults guidelines from the association of the scientific medical societies in Germany

2016

No abstract available.

Adultmedicine.medical_specialtyCritical CareHypovolemiaMEDLINEMedizinBlood volumelaw.inventionLactated ringers solution03 medical and health sciences0302 clinical medicineRandomized controlled trial030202 anesthesiologylawGermanymedicineIntravascular volume statusHumansddc:610Intensive care medicineBlood VolumeElective cesarean sectionbusiness.industryCentral venous pressure030208 emergency & critical care medicine3. Good healthAnesthesiology and Pain MedicineFluid Therapybusiness
researchProduct

Erythrocytes labeled with [18F]SFB as an alternative to radioactive CO for quantification of blood volume with PET

2013

Inhaled radioactive CO is currently the tracer of choice for blood volume quantification by positron emission tomography (PET). This measurement is of great interest for several clinical and research applications. However, owing to the short half-life of the radiolabeled CO, it can only be used in centers equipped with a cyclotron. In the present work, we propose an alternative method to label the red blood cells with [(18) F] in order to obtain blood volume measurements by PET. The use of the radioactive synthon [(18) F] N-succinimidyl 4-[(18) F]fluorobenzoate ([(18) F]SFB) was evaluated for erythrocyte labeling and PET blood volume imaging. The images provided by [(18) F]SFB labeled eryth…

Alternative methodsmedicine.diagnostic_testbusiness.industryChemistryRadiochemistryBlood volumeSprague dawleyPositronPositron emission tomographyIn vivoBlood volume measurementmedicineRadiology Nuclear Medicine and imagingNuclear medicinebusinessContrast Media & Molecular Imaging
researchProduct

Blood Pressure control by 24-hour Ambulatory Monitoring in Chronic Renal Failure.

2005

Blood pressure controlmedicine.medical_specialtyAmbulatory blood pressurebusiness.industryBlood volumeBlood pressureInternal medicineAmbulatoryInternal MedicineCardiologymedicineAortic pressureChronic renal failurebusinessBlood Pressure 24-hour Ambulatory Monitoring Chronic Renal Failure.
researchProduct

Flat Panel Computed Tomography Pooled Blood Volume and Infarct Prediction in Endovascular Stroke Treatment

2019

Background and Purpose— Patients with large-vessel stroke frequently need to be transferred to comprehensive stroke centers for endovascular treatment. An update of physiological perfusion parameters and stroke progression on arrival is desirable. We examined the reliability of preinterventional pooled blood volume (PBV)-maps acquired by flat-panel detector computed tomography (CT) in the interventional angiography suite. Methods— The volumes of preinterventional perfusion deficit in flat-panel detector CT-PBV source images were compared with final infarct volume on follow-up multislice-CT after endovascular treatment of 29 consecutive patients with occlusion of the middle cerebral artery …

Brain InfarctionMaleMechanical Thrombolysismedicine.medical_treatmentBlood volume030204 cardiovascular system & hematology03 medical and health sciencesPostoperative Complications0302 clinical medicinePredictive Value of Testsmedicine.arteryOcclusionmedicineCerebral Blood VolumeHumanscardiovascular diseasesStrokeAgedAdvanced and Specialized Nursingmedicine.diagnostic_testbusiness.industryCerebral infarctionEndovascular ProceduresThrombolysisMiddle Agedmedicine.diseaseCerebral AngiographyStrokeMiddle cerebral arteryAngiographyFemaleNeurology (clinical)Internal carotid arteryTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessNuclear medicine030217 neurology & neurosurgeryFollow-Up StudiesStroke
researchProduct

Effects of thrombin and of the phospholipase C inhibitor, D609, on the vascularity of the chick chorioallantoic membrane.

2000

Abstract Microvascular corrosion casting was used to assess the effects of thrombin and D609, a phospholipase C inhibitor, on the vascularity of the chick embryo chorioallantoic membrane (CAM). Discs containing vehicle, thrombin or D609 were placed on the CAM of fertilized white Leghorn eggs on Day 9 of gestation and vascularity was assessed on Day 11. Thrombin caused significant increases in the numbers (43%), diameters (5%) and lengths (17%), of both pre- and postcapillaries (first-order vessels by centripetal ordering). Conversely, D609 caused a decrease in the numbers (27%), lengths (12%) and diameters (8%) of first-order vessels. D609 decreased the total vascular volume of first- to th…

Bridged-Ring Compoundsmedicine.medical_specialtyanimal structuresAngiogenesisPhosphodiesterase InhibitorsNeovascularization PhysiologicChick EmbryoBiologyHemostaticsMicrocirculationThrombinVascularityAllantoisThiocarbamatesInternal medicinemedicineAnimalsOvumPharmacologyBlood VolumePhospholipase CThrombinThionesChorionNorbornanesChorioallantoic membraneEndocrinologymedicine.anatomical_structureType C PhospholipasesCirculatory systemMicroscopy Electron Scanningmedicine.symptommedicine.drugBlood vesselGeneral pharmacology
researchProduct

Hemodynamic Parameters Change Earlier Than Tissue Oxygen Tension in Hemorrhage

2010

BACKGROUND: Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. MATERIALS AND METHODS: Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after p…

Cardiac outputMean arterial pressureColonHypovolemiaSus scrofaHemodynamicsBlood PressureHemorrhageBlood volumeHypovolemiaLaser-Doppler FlowmetryIntravascular volume statusmedicineAnimalsCardiac OutputPulmonary wedge pressureBlood Volumebusiness.industryMicrocirculationHemodynamicsBlood flowHeart ArrestOxygenDisease Models AnimalJejunumLiverAnesthesiaAcute DiseaseSurgerymedicine.symptombusinessJournal of Surgical Research
researchProduct

Cardiac output following fetoscopic coagulation of major placental vessels in fetal sheep.

2008

Objectives To measure changes in cardiac output (CO) after partial cord occlusion in fetal sheep in order to investigate pathophysiological fetal adaptation mechanisms in a simulated acute placental insufficiency model under standardized conditions, with the aim of finding relevant methods for monitoring human fetuses during stress situations. Methods We used minimally invasive, percutaneous endoscopic techniques to close umbilical vessels in mid-gestational fetal sheep. Placental blood flow was reduced by preferentially closing first arterial and then the concomitant venous umbilical vessels within a short time interval. The investigations were carried out on 11 pregnant ewes at a median g…

Cardiac outputUmbilical VeinsPlacentaHemodynamicsBlood volumePlacental insufficiencyUltrasonography PrenatalUmbilical ArteriesFetusPregnancymedicine.arterymedicineAnimalsRadiology Nuclear Medicine and imagingCardiac OutputSheep DomesticRadiological and Ultrasound Technologybusiness.industryObstetrics and GynecologyUmbilical arteryGeneral MedicineStroke volumemedicine.diseasemedicine.anatomical_structureReproductive MedicineUltrasonography Doppler PulsedAnesthesiaPulsatile FlowFemalebusinessDuctus venosusBlood Flow VelocityBlood vesselUltrasound in obstetricsgynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
researchProduct