Search results for "Blood vessel prosthesis implantation"
showing 10 items of 106 documents
ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA
2009
This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…
Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…
2020
Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…
Initial Experience in the Treatment of Extensive Iliac Artery Aneurysms With the Nellix Aneurysm Sealing System.
2016
Purpose: To assess the feasibility and effectiveness of the Nellix prosthesis in the treatment of common iliac artery aneurysms. Methods: Between May 2013 and June 2015, 230 patients underwent implantation of the Nellix device at 2 institutions. Fifty of these patients (mean age 76 years; 35 men) were identified as having 60 common iliac artery aneurysms (CIAAs) with a median diameter of 4 cm (range 3.5–7). The majority of patients had aortoiliac aneurysms (5, 70%), 10 (20%) had isolated CIAAs, and 5 (10%) had iliac anastomotic aneurysms after aortoiliac bypass. In 20 patients, the iliac aneurysm was the indication for the intervention; in the other 30 patients, the endovascular iliac repa…
Renewed endovascular repair for recurrent acute abdominal aortic aneurysm
2008
The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperative…
A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.
2015
Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…
A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…
2012
Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …
Outpatient endovascular aortic aneurysm repair: Experience in 100 consecutive patients
2013
OBJECTIVES:: To present the safety, feasibility, costs, and patient satisfaction of outpatient endovascular aneurysm repair (EVAR). BACKGROUND:: Our experience in more than 1000 patients indicated that in technically uncomplicated EVAR procedures, the only need for hospitalization was for access vessel complications (bleeding or occlusion) requiring secondary procedures. These complications could always be identified within the first 3 hours after EVAR. METHODS:: Two-center retrospective analysis of prospectively gathered data on 100 consecutive elective outpatient EVAR cases (Outpt EVAR). Inclusion criteria for Outpt EVAR were as follows: asymptomatic clinical state, informed consent, trav…
Endograft connector technique to treat popliteal artery aneurysm in a morbid obese patient.
2015
Surgical repair of popliteal artery aneurysm in morbid obese patients poses additional challenges. We report a morbid obese patient who had a 59 mm right popliteal artery aneurysm which was successfully treated with the endograft connector technique. This technique was used to perform the distal anastomosis of the below-knee femoro-popliteal bypass. A 10 mm Dacron graft was used as a main graft bypass and an 11 mm/10 cm stentgraft as endograft connector. Following the respective tunnel of the Dacron graft, an end-to-side proximal anastomosis was performed at distal femoral artery. The aneurysm exclusion was obtained through a proximal and a distal ligation. Postoperative duplex showed adeq…
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …