Search results for "Brachytherapy"
showing 10 items of 168 documents
Novel simple templates for reproducible positioning of skin applicators in brachytherapy.
2016
Purpose : Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the po…
Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.
2017
Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…
Role of Surgical Versus Clinical Staging in Chemoradiated FIGO Stage IIB-IVA Cervical Cancer Patients—Acute Toxicity and Treatment Quality of the Ute…
2015
The Uterus-11 trial was designed to evaluate the role of surgical staging in patients with cervical cancer before primary chemoradiation therapy (CRT). The present report provides the toxicity data stratified by the treatment arm and technique.A total of 255 patients with carcinoma of the uterine cervix (International Federation of Gynecology and Obstetrics stage IIB-IVA) were randomized to either surgical staging followed by CRT (arm A) or clinical staging followed by CRT (arm B). Patients with para-aortic metastases underwent extended field radiation therapy (RT). Brachytherapy was mandatory. The present report presents the acute therapy-related toxicities stratified by treatment arm and …
Monitoring of rheologic variables during postoperative high-dose brachytherapy for uterine cancer.
2004
Oxygenation of tumor tissue has recently been assed an important prerequisite for the effectiveness of radiotherapy in cervical cancer. Hyperviscosity is a common phenomenon in malignancy and a cause of reduced oxygen transport capacity that would favour tissue hypoxia. Hemorheological variables were serially tested preoperatively, during four cycles of fractionated adjuvant IR192 HDR after loading radiation (HDR-AL) of the vaginal vault (weekly intervals), and 6 months postoperatively in patients with cervical (n=12) and endometrial cancer (n=26). Women who were scheduled for benign tumor surgery served as controls (n=29). Preoperatively, in cervical and endometrial cancer patients, mean …
A new method for the placement of brachytherapy probes in paranasal sinus and nasopharynx neoplasms
1999
Abstract Purpose: In afterloading therapy, the exact placement of the applicator is crucial for the result of radiotherapy. A deviation of few millimeters from the target leads to a significant reduction of radiation energy to the tumor. Methods and Materials: We present a new method using a computer-assisted device for three-dimensional placing of afterloading probes based on CT scans that allows for the exact placement. Results: Target points have been reached with an accuracy of 0.6 mm. Since 1991 we have used this technique for 24 clinical applications in 11 patients with recurrent neoplasms in the region of the paranasal sinuses and nasopharynx for palliative treatment. Conclusions: Th…
Tumor oxygenation: a new predictive parameter in locally advanced cancer of the uterine cervix.
1993
Abstract Experimental evidence suggests that hypoxia may increase the malignant potential and reduce the sensitivity toward nonsurgical treatment modalities in solid rodent tumors. However, the importance of tumor hypoxia in human malignancies is still uncertain. We have developed a clinically applicable standardized procedure for the determination of intratumoral p O 2 in advanced cervical cancers by use of a computerized polarographic needle electrode histograph. To evaluate the significance of tumor oxygenation as a new oncologic parameter we initiated an open prospective clinical trial at the University of Mainz Medical Center in June 1989. Until October 1992 50 patients with advanced c…
The combined operative and radiotherapeutic treatment (CORT) of recurrent tumors infiltrating the pelvic wall: First experience with 18 patients
1992
CORT is a new radiosurgical treatment concept for patients with recurrent gynecologic malignancies infiltrating the pelvic wall. The operative part consists of (i) staging laparotomy; (ii) maximum debulking of the tumor from the pelvic wall and exenteration of infiltrated central pelvic organs; (iii) implantation of brachytherapy guiding tubes on the residual tumor/tumor bed at the pelvic wall; (iv) pelvic wall plasty with muscle and omentum flaps to create a protective distance between the tubes and the pelvic hollow organs and to induce therapeutic angiogenesis; and (v) surgical reconstruction of bowel, bladder, and vulvoperineovaginal functions. Radiation is given postoperatively as frac…
Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.
2015
To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…
Artificial intelligence for image-guided prostate brachytherapy procedures
2020
Radiotherapy procedures aim at exposing cancer cells to ionizing radiation. Permanently implanting radioactive sources near to the cancer cells is a typical technique to cure early-stage prostate cancer. It involves image acquisition of the patient, delineating the target volumes and organs at risk on different medical images, treatment planning, image-guided radioactive seed delivery, and post-implant evaluation. Artificial intelligence-based medical image analysis can benefit radiotherapy procedures. It can help to facilitate and improve the efficiency of the procedures by automatically segmenting target organs and extrapolating clinically relevant information. However, manual delineation…
A dosimetric study of Leipzig applicators.
2005
Purpose: To obtain the absolute dose-rate distribution in liquid water for all six cup-shaped Leipzig applicators by means of an experimentally validated Monte Carlo (MC) code. These six applicators were used in high-dose-rate (HDR) afterloaders with the “classic” and v2 192Ir sources. The applicators have an inner diameter of 1, 2, and 3 cm, with the source traveling parallel or perpendicular to the contact surface. Methods and materials: The MC GEANT4 code was used to obtain the dose-rate distribution in liquid water for the six applicators and the two HDR source models. To normalize the applicator output factors, a MC simulation for the “classic” and v2 sources in air was performed to es…