Electric field manipulation in Al/CdTe/Pt detectors under optical perturbations

2017

Abstract Al/CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopy, even though they suffer from polarization phenomena, which cause a progressive time degradation of the spectroscopic performance. In this work we investigated on the time dependence of the electric field of an Al/CdTe/Pt detector under optical perturbation by means of Pockels effect measurements. A tunable laser with wavelengths ranging within 700−1000 nm and a 940 nm light emitting diode (LED) were used. The measurements of both the electric field profile and the total current were used to better understand the effects of the optical perturbation on polarization phenomena. The results point ou…

Nuclear and High Energy Physics02 engineering and technology01 natural sciencesInduced polarizationlaw.inventionCdTe detectorX-ray and gamma ray spectroscopylawPolarizationElectric fieldElectric field0103 physical sciencesInstrumentationNuclear and High Energy Physic010302 applied physicsPhysicsbusiness.industrySettore FIS/01 - Fisica SperimentaleBiasing021001 nanoscience & nanotechnologySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Pockels effectAnodeWavelengthOptoelectronicsInfrared illumination0210 nano-technologybusinessPockels effectTunable laserLight-emitting diodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Time-dependent electric field in Al/CdTe/Pt detectors

2015

Abstract Al/CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopy, even though they suffer from bias-induced time instability (polarization). Polarization phenomena cause a progressive time-degradation of the spectroscopic performance of the detectors, due to hole trapping and detrapping from deep acceptor levels that directly control the electric field distribution. In this work we present experimental investigations on the electric field profile of planar Al/CdTe/Pt detectors by means of Pockels effect measurements. The time/temperature dependence of the electric field was investigated in a long time window (up to 10 h) and the correlation with the reverse c…

PhysicsNuclear and High Energy PhysicsDeep acceptor levelbusiness.industryTrappingAcceptorPockels effectCadmium telluride photovoltaicsCdTe detectorX-ray and gamma ray spectroscopyPlanarPolarizationElectric fieldElectric fieldOptoelectronicsAtomic physicsPolarization (electrochemistry)businessSpectroscopyPockels effectInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Digital performance improvements of a CdTe pixel detector for high flux energy-resolved X-ray imaging

2015

Abstract Photon counting detectors with energy resolving capabilities are desired for high flux X-ray imaging. In this work, we present the performance of a pixelated Schottky Al/p-CdTe/Pt detector (4×4) coupled to a custom-designed digital readout electronics for high flux measurements. The detector (4×4×2 mm 3 ) has an anode layout based on an array of 16 pixels with a geometric pitch of 1 mm (pixel size of 0.6 mm). The 4-channel readout electronics is able to continuously digitize and process the signals from each pixel, performing multi-parameter analysis (event arrival time, pulse shape, pulse height, pulse time width, etc.) even at high fluxes and at different throughput and energy re…

PhysicsNuclear and High Energy PhysicsPixelPhysics::Instrumentation and Detectorsbusiness.industryEnergy-resolved photon counting detectorSettore FIS/01 - Fisica SperimentaleDetectorSchottky diodePixel detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Photon countingCharge sharingCdTe detectorHigh photon counting rateFull width at half maximumOpticsDigital pulse processingMonochromatic colorbusinessInstrumentationPulse shape analysiEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Polarization phenomena in Al/p-CdTe/Pt X-ray detectors

2013

Over the last decades, CdTe detectors are widely used for the development of room temperature X-ray and gamma ray spectrometers. Typically, high resolution CdTe detectors are fabricated with blocking contacts (indium, aluminum) ensuring low leakage currents and high electric field for optimum charge collection. As well known, time instability under bias voltage (termed as polarization) is the major drawback of CdTe diode detectors. Polarization phenomena cause a progressive degradation of the spectroscopic performance with time, due to hole trapping and detrapping from deep acceptors levels. In this work, we studied the polarization phenomenon on new Al/p-CdTe/Pt detectors, manufactured by …

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryX-ray detectorchemistry.chemical_elementBiasingAcceptorCadmium telluride photovoltaicsSchottky CdTe detectorCondensed Matter::Materials SciencechemistryPolarizationElectric fieldActivation energyX-rayandgamma ray spectroscopyOptoelectronicsbusinessPolarization (electrochemistry)InstrumentationIndiumNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Performance enhancements of compound semiconductor radiation detectors using digital pulse processing techniques

2011

Abstract The potential benefits of using compound semiconductors for X-ray and gamma ray spectroscopy are already well known. Radiation detectors based on high atomic number and wide band gap compound semiconductors show high detection efficiency and good spectroscopic performance even at room temperature. Despite these appealing properties, incomplete charge collection is a critical issue. Generally, incomplete charge collection, mainly due to the poor transport properties of the holes, produces energy resolution worsening and the well known hole tailing in the measured spectra. In this work, we present a digital pulse processing (DPP) system for high resolution spectroscopy with compound …

PhysicsNuclear and High Energy PhysicsSpectrometerPreamplifierbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleCompound semiconductors CdTe detectors X-ray and gamma ray spectroscopy Digital pulse processing Pulse height analysis Pulse shape analysisParticle detectorPulse (physics)OpticsGamma spectroscopySpectroscopybusinessInstrumentationShape analysis (digital geometry)
researchProduct

Performance of a digital CdTe X-ray spectrometer in low and high counting rate environment

2010

Abstract The high performances of CdTe detectors for X-ray and gamma ray spectroscopy are already well known. Among the traditional semiconductor spectrometers, CdTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact detection systems. In this work, we investigated the performance of a CdTe detector coupled with a custom digital pulse processing (DPP) system for X-ray spectroscopy. The DPP method, implemented on a PC platform, performs a pile-up inspection and a pulse height analysis of the preamplifier output pulses, digitized by a 14-bit, 100 MHz ADC. The spectroscopic results point out the excellent performanc…

PhysicsNuclear and High Energy PhysicsX-ray spectroscopySpectrometerPhysics::Instrumentation and Detectorsbusiness.industryPreamplifierSettore FIS/01 - Fisica SperimentaleDetectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Photon countingOpticsSemiconductorGamma spectroscopyCdTe detectors X-ray spectroscopy Digital pulse processingbusinessSpectroscopyInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

X-ray spectroscopy and dosimetry with a portable CdTe device.

2007

Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…

PhysicsX-ray spectroscopy CdTe detectorsNuclear and High Energy Physicsmedicine.medical_specialtyReproducibilitybusiness.industryDetectorExposure HVLFluenceFull width at half maximumQuality (physics)OpticsmedicineDosimetryMedical physicsSpectroscopybusinessInstrumentationHalf-value layer
researchProduct

Characterization of Al-Schottky CdTe detectors

2011

In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …

PhysicsX-ray spectroscopySpectrometerbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorSchottky diodeBiasingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeCdTe detectorFull width at half maximumX-ray and gamma ray spectroscopyOpticsOptoelectronicsGamma spectroscopybusiness2011 IEEE Nuclear Science Symposium Conference Record
researchProduct

Electrical Characterization of CdTe pixel detectors with Al Schottky anode

2014

Abstract Pixelated Schottky Al/p-CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopic imaging, even though they suffer from bias-induced time instability (polarization). In this work, we present the results of the electrical characterization of a (4×4) pixelated Schottky Al/p-CdTe/Pt detector. Current–voltage ( I–V ) characteristics and current transients were investigated at different temperatures. The results show deep levels that play a dominant role in the charge transport mechanism. The conduction mechanism is dominated by the space charge limited current (SCLC) both under forward bias and at high reverse bias. Schottky barrier height of the Al/CdTe con…

PhysicspolarizationNuclear and High Energy PhysicsSchottky contactbusiness.industrySchottky barrierSettore FIS/01 - Fisica SperimentaleSchottky diodeCdTeThermal conductionSpace chargeCadmium telluride photovoltaicsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Settore FIS/03 - Fisica Della MateriaAnodeX-ray and gamma ray spectroscopypixel detectorOptoelectronicsPolarization (electrochemistry)businessCdTe; Schottky contacts; polarization; pixel detectors; X-ray and gamma ray spectroscopyInstrumentationVoltage
researchProduct

Digital CZT detector system for high flux energy-resolved X-ray imaging

2017

Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…

Radiology Nuclear Medicine and ImagingPhysics::Instrumentation and DetectorsPreamplifier01 natural sciences030218 nuclear medicine & medical imagingCharge sharing03 medical and health sciences0302 clinical medicineOptics0103 physical sciencesInstrumentationNuclear and High Energy PhysicPhysicsPixel010308 nuclear & particles physicsbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleGamma raySMALL PIXEL; CDTE; PERFORMANCE; RESOLUTION; PROGRESS; CTPhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electronic Optical and Magnetic MaterialsPixieMonochromatic colorbusiness
researchProduct