Search results for "CHAMBER"
showing 10 items of 359 documents
A highly-segmented ΔE-time-of-flight wall as forward detector of the 4π-system for charged particles at the SIS/ESR accelerator
1993
Abstract At the SIS/ESR accelerator facility at GSI in Darmstadt the 4π-detector system FOPI is under construction at present. It is designed for the investigation of central collisions of heavy ions in the energy range up to 2 A GeV. As phase I of this detector a forward wall has been built and used in various experiments. It comprizes a total number of 764 scintillators with an additional shell of 188 thin ΔE -detectors in front of it and covers the full azimuth of the polar angles from 1° to 30°. The velocity and the nuclear charge of the fragments are determined by a combined time-of-flight and ΔE measurement.
Layout and performance of RPC used in the Argo-YBJ experiment
2006
The layout of the RPCs, used in the Argo-YBJ experiment to image with a high space-time granularity the atmospheric shower, is described in this paper. The detector has been assembled to provide both digital and analog informations in order to cover a wide particle density range with a time accuracy of 1 ns. The experimental results obtained operating the chambers in streamer mode at sea level with a standard gas mixture are presented. (c) 2006 Elsevier B.V. All rights reserved.
STUDIES OF WIRE GAIN AND TRACK DISTORTION NEAR THE SECTOR EDGES OF THE ALEPH TIME PROJECTION CHAMBER
1986
Abstract The materials used to hold the wires at the sector edges in a large Time Projection Chamber (TPC) inrtoduce distortions of the electric drift field near those edges. These distortions degrade tracking information and sometimes cause large changes in wire gain near the edge. We have studied these two problems for the ALEPH TPC and have found that both can be greatly reduced by the addition of two field correction strips held at appropriate voltages.
PERFORMANCE OF THE ALEPH TIME PROJECTION CHAMBER
1991
The performance of the ALEPH Time Projection Chamber (TPC) has been studied using data taken during the LEP running periods in 1989 and 1990. After correction of residual distortions and optimisation of coordinate reconstruction algorithms, single coordinate resolutions of 173-mu-m in the azimuthal and 740-mu-m in the longitudinal direction are achieved. This results in a momentum resolution for the TPC of DELTA-p/p2 = 1.2 x 10(-3) (GeV/c)-1. In combination with the ALEPH Inner Tracking Chamber (ITC), a total momentum resolution of DELTA-p/p2 = 0.8 x 10(-3) (GeV/c)-1 is obtained. With respect to particle identification, the detector achieves a resolution of 4.4% for the measurement of the i…
The X-ray Facility at LAX in Palermo
1996
A description is given of the X-ray facility installed at LAX (Laboratorio per Sperimentazioni con Radiazioni X), jointly operated in Palermo by the DEAF (Department of Energy and Physics Applications) of the University of Palermo and the IFCAT (Institute of Cosmic Physics and Informatics) of the Italian National Research Council. The X-rays are produced by bombarding a target with energized electrons up to 60 keV. Depending on the material of the target, characteristic fluorescence lines as well as continuous bremsstrahlung is emitted. The X-ray beam has an operational energy range of 0,1–25 keV with a flux of 1010–1012 photons/sr · s; the beam, collimated on a length of 10,5 m, has a diam…
Test of the generation of High-Frequency Gravitational Waves by irradiating a dielectric film in a resonant cavity
2004
A recent proposal for generating High Frequency Gravitational Waves (HFGW) is based on the conversion of electromagnetic waves into gravitational waves by irradiating a dielectric film in the extreme conditions of a high vacuum and a strong magnetic field. These HFGWs can be tested using an electron paramagnetic resonant spectrometer (EPRS). This device contains all the necessary ingredients: a vacuum chamber, microwave generator, a strong magnetic field, and a resonant cavity where the substance to be analysed is introduced. The EPR spectrum of a very small paramagnetic core in a substance is the graph of the absorption of the paramagnetic core as a function of the strong magnetic field B.…
Neutrino mass ordering at DUNE: An extra ν bonus
2019
We study the possibility of extracting the neutrino mass ordering at the future Deep Underground Neutrino Experiment using atmospheric neutrinos, which will be available before the muon neutrino beam starts being perational. The large statistics of the atmospheric muon neutrino and antineutrino samples at the far detector, together with the baselines of thousands of kilometers that these atmospheric (anti)neutrinos travel, provide the ideal ingredients to extract the neutrino mass ordering via matter effects in the neutrino propagation through the Earth. Crucially, muon capture by Argon provides excellent charge-tagging, allowing to disentangle the neutrino and antineutrino signature. This …
New determination of the N-Δ(1232) axial form factors from weak pion production and coherent pion production off nuclei at T2K and MiniBooNE energies…
2010
We re-evaluate our model predictions in Phys. Rev. D 79, 013002 (2009) for different observables in neutrino induced coherent pion production. This comes as a result of the new improved fit to old bubble chamber data of the dominant axial C_5^A nucleon-to-Delta form factor. We find an increase of 20%-30% in the values for the total cross sections. Uncertainties induced by the errors in the determination of C_5^A are computed. Our new results turn out to be compatible within about $1\sigma$ with the former ones. We also stress the existing tension between the recent experimental determination of the \sigma(CC coh \pi^+)}/\sigma(NC coh \pi^0)} $ ratio by the SciBooNE Collaboration and the the…
Muon-pair production by atmospheric muons in cosmoALEPH
2006
Data from a dedicated cosmic ray run of the ALEPH detector were used in a study of muon trident production, i.e., muon pairs produced by muons. Here the overburden and the calorimeters are the target materials while the ALEPH time projection chamber provides the momentum measurements. A theoretical estimate of the muon trident cross section is obtained by developing a Monte Carlo simulation for muon propagation in the overburden and the detector. Two muon trident candidates were found to match the expected theoretical pattern. The observed production rate implies that the nuclear form factor cannot be neglected for muon tridents.
Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.
2020
The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…