Search results for "CHEMILUMINESCENCE"

showing 10 items of 86 documents

FI automatic method for the determination of copper(II) based on coproporphyrin I-Cu(II)/TCPO/H(2)O(2) chemiluminescence reaction for the screening o…

2004

Abstract In this paper, an automatic method for the screening of water samples containing Cu(II) was proposed, based on peryoxalate chemiluminescence reaction using coproporphyrin I as fluorophor compound to provide selectivity and a simple flow injection (FI) chemiluminescence detector (CLD). FI system conditions were chosen in order to distinguish samples over or under legislation limit established (50 μg l−1) with high reliability. The detection limit found was 9 μg l−1 and the linear dynamic range was 15–125 μg l−1 of Cu(II). Repeatibility and reproducibility studies gave good precision and accuracy with recovery near 100%. Under these conditions, the method resulted selective and only …

Detection limitReproducibilityAccuracy and precisionChemistryAnalytical chemistrychemistry.chemical_elementCopperAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawTCPOSelectivityHydrogen peroxideChemiluminescenceTalanta
researchProduct

Photo-induced chemiluminescence determination of the pesticide Buminafos by a Multicommutation flow-analysis assembly

2008

Abstract The preliminary experiments in this paper deal with the photo-induced chemiluminescent behaviour of Buminafos family, after the experimental screening tests and several of them resulted positive, the herbicide Buminafos was selected to develop a new analytical method. The determination of Buminafos was performed with the aid of a Multicommutation (a solenoid valve set) assembly. The method involves the on-line photo-degradation of the analyte (stopped flow, 5 s) with the selected suitable medium (0.05% hydrogen peroxide) and its subsequent chemiluminescent oxidation by the potassium permanganate. Sample solution alternated segments with the photo-degradation medium; and, after the …

Detection limitReproducibilityAnalyteChromatographyScreening testAnalytical chemistryPesticideAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistrylawHydrogen peroxideChemiluminescenceTalanta
researchProduct

Photo-induced chemiluminescence-based determination of diphenamid by using a multicommuted flow system

2007

This manuscript deals with the application of molecular connectivity calculations to predict the photo-induced chemiluminescent behaviour of the family of herbicides grouped as amides. Several compounds of this group were theoretically studied by means of a general discriminant equation formerly obtained, being 18 of them (plus eight from the chloroacetanilide sub-group) predicted with a high probability as photo-induced chemiluminescent. Empirical confirmation of the chemiluminometric behaviour was performed with some few commercially available amide herbicides. On the basis of these results, a new multicommutation-photo-chemiluminescent method is proposed for the determination of the diph…

Detection limitReproducibilityChromatographyChemistryAnalytical chemistryRepeatabilityAnalytical Chemistrylaw.inventionchemistry.chemical_compoundSodium hydroxidelawAmideCalibrationPhotodegradationChemiluminescenceTalanta
researchProduct

Sensitive determination of aliphatic amines in water by high-performance liquid chromatography with chemiluminescence detection.

2004

A sensitive method has been developed for liquid chromatographic determination of short aliphatic amines in water samples. Analytes are preconcentrated and dansylated on solid sorbents (C18 solid-phase extraction cartridges). The dansyl derivatives are chromatographed and post-column mixed with peroxyoxalate (TCPO) and H2O2 in order to perform chemiluminescence detection. Optimal results have been obtained using a sample volume of 5 ml. The method has been applied to the quantification or screening of several aliphatic amines: methylamine, ethylamine, butylamine, diethylamine, pentylamine and hexylamine. The screening procedure has been developed including also polyamines (putrescine, cadav…

DiethylamineDetection limitChromatographyOrganic ChemistryGeneral MedicineBiochemistryHigh-performance liquid chromatographyPeroxyoxalateSensitivity and SpecificityAnalytical Chemistrylaw.inventionchemistry.chemical_compoundSpectrometry FluorescencechemistrylawHexylamineLuminescent MeasurementsSpectrophotometry UltravioletEthylaminePentylamineAminesChromatography High Pressure LiquidChemiluminescenceJournal of chromatography. A
researchProduct

Flow-injection analysis study of the chemiluminescent behaviour of proflavine and acriflavine

2001

Abstract The chemiluminescent behaviour of the amino acridines like acriflavine, and proflavin is reported. Different strong oxidants (potassium permanganate, cerium(IV), hexacyanoferrate(III), hydrogen peroxide in different media) were tested, and potassium permanganate in sulphuric acid medium was selected. The study of the experimental parameters affecting the oxidation and detection was performed with the aid of a FIA assembly. The calibration graph was applied over the range 0.05–12.0 μg ml −1 of acriflavine (regression coefficient 0.9957, and the calculated relative standard deviation (R.S.D., %) was 0.9; LOD 10 ng ml −1 and the sample throughput 48 h −1 . The study of interfering com…

Flow injection analysisCalibration curveInorganic chemistryAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionAcridonechemistry.chemical_compoundPotassium permanganatechemistrylawEnvironmental ChemistryAcriflavineHydrogen peroxideSpectroscopyProflavineChemiluminescenceAnalytica Chimica Acta
researchProduct

Direct flow injection chemiluminescence determination of salicylamide

1999

Abstract A new direct flow injection chemiluminescence method is proposed for the determination of salicylamide, based upon the oxidation of the drug by potassium permanganate in dilute sulphuric acid. The calibration graph is linear over the range 20 ng ml−1 (30 limit of detection)–8 μg ml−1 salicylamide, with a relative standard deviation (n=50, 0.5 μg ml−1) of 1.7%. The average sample insertion rate is 142 h−1. The influence of relevant foreign compounds is found to be relatively slight. The method is applied to the determination of salicylamide in a pharmaceutical formulation and human urine.

Flow injection analysisDetection limitChromatographyCalibration curvePermanganateSalicylamidePharmaceutical formulationBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistrylawmedicineEnvironmental ChemistrySpectroscopymedicine.drugChemiluminescenceAnalytica Chimica Acta
researchProduct

An aptamer-gated silica mesoporous material for thrombin detection.

2013

An aptamer-capped mesoporous material for the selective and sensitive detection of &-thrombin in human plasma and serum has been prepared and characterised.

INGENIERIA DE LA CONSTRUCCIONSilicon dioxideAptamerInorganic chemistryNanoparticleAptamersCatalysisFluorescencechemistry.chemical_compoundThrombinQUIMICA ORGANICAQUIMICA ANALITICAMaterials ChemistrymedicineElectrochemiluminescenceHumansHuman Alpha-ThrombinElectrochemiluminescenceMagnetic beadssilicon dioxidePropylaminesChemistryRhodaminesQUIMICA INORGANICAMetals and AlloysThrombinGeneral ChemistryAptamers NucleotideSilanesSilicon DioxideFluorescenceSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsSpectrometry FluorescenceHuman plasmaCeramics and CompositesNanoparticlesMesoporous materialNucleotidePorosityColorimetric detectionmedicine.drugNuclear chemistryChemical communications (Cambridge, England)
researchProduct

Sequential injection analysis (SIA)-chemiluminescence determination of indomethacin using tris[(2,2'-bipyridyl)]ruthenium(III) as reagent and its app…

2006

Abstract Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin ( I ) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy) 3 3+ ) in the presence of acetate. The Ru(bipy) 3 3+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy) 3 2+ ) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy) 3 …

IndomethacinAnalytical chemistrychemistry.chemical_elementBiochemistryDosage formAnalytical Chemistrylaw.inventionlawSpectrophotometrymedicineOrganometallic CompoundsEnvironmental ChemistrySpectroscopyChemiluminescenceDetection limitDosage FormsAqueous solutionmedicine.diagnostic_testMolecular StructureReproducibility of ResultsRutheniumStandard curvechemistryReagentCalibrationFlow Injection AnalysisLuminescent MeasurementsSolventsNuclear chemistryAnalytica chimica acta
researchProduct

Chemi- and Bioluminescence of Cyclic Peroxides

2018

Bioluminescence is a phenomenon that has fascinated mankind for centuries. Today the phenomenon and its sibling, chemiluminescence, have impacted society with a number of useful applications in fields like analytical chemistry and medicine, just to mention two. In this review, a molecular-orbital perspective is adopted to explain the chemistry behind chemiexcitation in both chemi- and bioluminescence. First, the uncatalyzed thermal dissociation of 1,2-dioxetane is presented and analyzed to explain, for example, the preference for triplet excited product states and increased yield with larger nonreactive substituents. The catalyzed fragmentation reaction and related details are then exemplif…

Luminescence010402 general chemistry01 natural sciencesCatalysislaw.inventionFragmentation (mass spectrometry)BIOLUMINESCÊNCIAComputational chemistrylawArtificial systemsBioluminescenceSinglet stateComputingMilieux_MISCELLANEOUSChemiluminescenceMolecular Structure010405 organic chemistryChemistryGeneral ChemistryPeroxides0104 chemical sciences3. Good health[CHIM.THEO]Chemical Sciences/Theoretical and/or physical chemistryExcited stateYield (chemistry)Thermal dissociationLuminescent Measurements
researchProduct

Photoinduced chemiluminescence of pharmaceuticals

2005

Abstract A screening test for the forward development of chemiluminescence systems able to determine pharmaceutical compounds is reported. The test is based on the on-line photodegradation of the drugs by using a photoreactor consisting of 697 cm × 0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegraded pharmaceuticals are detected by direct chemiluminescence of the resulting photofragments and their subsequent reaction with potassium permanganate in sulphuric acid medium as oxidant. The screening comprised 97 compounds with different molecular structures and relevant members of the most important families of pharmaceuticals are tested (amino acids, carbox…

LuminescenceLightScreening testPhotochemistryClinical BiochemistryPharmaceutical Sciencebeta-LactamsAnalytical Chemistrylaw.inventionStructure-Activity Relationshipchemistry.chemical_compoundAlkaloidsOxidants PhotochemicalPotassium PermanganatePhenothiazineslawDrug DiscoverymedicineOrganic chemistryEphedrinePhotodegradationSpectroscopyChemiluminescencechemistry.chemical_classificationBicyclic moleculePhotodissociationHydrogen-Ion ConcentrationAmino acidPotassium permanganatePharmaceutical Preparationschemistrymedicine.drugJournal of Pharmaceutical and Biomedical Analysis
researchProduct