Search results for "CONTACT"

showing 10 items of 1003 documents

Wettability and compositional analysis of hydroxyapatite films modified by low and high energy ion irradiation

2008

Abstract Hydroxyapatite-like thin films on silicon substrate were deposited using atomic layer deposition and were subjected to irradiation with Ar ions accelerated through 0.6–1.2 kV as well as 2 MeV 16 O + ions. After low energy Ar irradiation a significant reduction in contact angle was observed. However, the Ca/P atomic ratio remained unchanged. No reduction in contact angle was seen for high energy 16 O + irradiation. Atomic force microscopy showed the enhancement of floral-like pattern after low energy Ar bombardment while high energy oxygen irradiation lead to raised islands on as-deposited films.

Nuclear and High Energy PhysicsMaterials scienceSiliconAnalytical chemistrychemistry.chemical_elementSubstrate (electronics)IonContact angleAtomic layer depositionchemistryAtomic ratioIrradiationThin filmInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Development of new CdZnTe detectors for room-temperature high-flux radiation measurements

2017

Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…

Nuclear and High Energy PhysicsPreamplifier02 engineering and technologydigital pulse shape analysiRadiation01 natural scienceslaw.inventionPlanarOpticstravelling heater methodlaw0103 physical scienceshigh fluxInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy PhysicPhysicsRadiationdigital pulse shape analysis010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica SperimentaleX-ray and γ-ray detectorenergy-resolved photon-counting detector021001 nanoscience & nanotechnologyCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Anodegold electroless contactFull width at half maximumX-ray and -ray detectors0210 nano-technologybusinessVoltage
researchProduct

Electrical properties of Au/CdZnTe/Au detectors grown by the boron oxide encapsulated Vertical Bridgman technique

2016

Abstract In this work we report on the results of electrical characterization of new CdZnTe detectors grown by the Boron oxide encapsulated Vertical Bridgman technique (B-VB), currently produced at IMEM-CNR (Parma, Italy). The detectors, with gold electroless contacts, have different thicknesses (1 and 2.5 mm) and the same electrode layout, characterized by a central anode surrounded by a guard-ring electrode. Investigations on the charge transport mechanisms and the electrical contact properties, through the modeling of the measured current–voltage ( I – V ) curves, were performed. Generally, the detectors are characterized by low leakage currents at high bias voltages even at room tempera…

Nuclear and High Energy PhysicsTraveling heater method electrical propertie02 engineering and technology01 natural sciencesBoron oxide encapsulated Vertical Bridgman techniqueTraveling heater methodElectrical resistivity and conductivity0103 physical sciencesInstrumentationDeposition (law)010302 applied physicsPhysicsInterfacial layer-thermionic-diffusionbusiness.industryCdZnTe detectorsCdZnTe detectorSettore FIS/01 - Fisica SperimentaleBiasing021001 nanoscience & nanotechnologySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electrical contactsAnodeBoron oxideelectrical propertiesElectrodeOptoelectronics0210 nano-technologybusinessVoltageNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A rescaling algorithm for the numerical solution to the porous medium equation in a two-component domain

2016

Abstract The aim of this paper is to design a rescaling algorithm for the numerical solution to the system of two porous medium equations defined on two different components of the real line, that are connected by the nonlinear contact condition. The algorithm is based on the self-similarity of solutions on different scales and it presents a space-time adaptable method producing more exact numerical solution in the area of the interface between the components, whereas the number of grid points stays fixed.

Numerical AnalysisInterface (Java)Component (thermodynamics)Applied Mathematics010102 general mathematicsMathematical analysisGrid01 natural sciencesDomain (mathematical analysis)010101 applied mathematicsNonlinear systemModeling and SimulationContact condition0101 mathematicsPorous mediumAlgorithmReal lineMathematicsCommunications in Nonlinear Science and Numerical Simulation
researchProduct

Active macro-zone approach for incremental elastoplastic-contact analysis

2013

SUMMARY The symmetric boundary element method, based on the Galerkin hypotheses, has found an application in the nonlinear analysis of plasticity and in contact-detachment problems, but both dealt with separately. In this paper, we want to treat these complex phenomena together as a linear complementarity problem. A mixed variable multidomain approach is utilized in which the substructures are distinguished into macroelements, where elastic behavior is assumed, and bem-elements, where it is possible that plastic strains may occur. Elasticity equations are written for all the substructures, and regularity conditions in weighted (weak) form on the boundary sides and in the nodes (strong) betw…

Numerical AnalysisNonlinear systemMatrix (mathematics)Applied MathematicsMathematical analysisGeneral EngineeringContact analysisBoundary (topology)Galerkin methodBoundary element methodLinear complementarity problemMathematicsVariable (mathematics)International Journal for Numerical Methods in Engineering
researchProduct

Recent advances in the application of pulsed light processing for improving food safety and increasing shelf life

2019

Abstract Background New technologies of non-thermal disinfection such as pulsed light (PL) have emerged lately as an alternative to traditional (thermal and chemical) disinfection and preservation methods. PL can be used to decontaminate a great variety of foods as well as to decontaminate contact surfaces, thus improving safety in foods and extending their shelf life. Moreover, this technology can prevent or reduce some of the detrimental effects of traditional methods on nutrients and bioactive compounds of food products. Scope and approach The combination of PL with other techniques such as ultraviolet light (UV), thermosonication (TS), pulsed electric fields (PEF), manothermosonication …

Nutritive value0303 health sciencesPreservation methods030306 microbiologybusiness.industry04 agricultural and veterinary sciencesHuman decontaminationContaminationShelf lifeFood safety040401 food scienceMicrobial inactivation03 medical and health sciences0404 agricultural biotechnologyContact surfacesPulsed lightSensory propertiesUltraviolet lightNon-thermal technologyEnvironmental scienceMicrobial decontaminationbusinessProcess engineeringFood ScienceBiotechnologyTrends in Food Science & Technology
researchProduct

Screening contact allergens from cosmetics using an optical biosensor

2006

OPTICAL BIOSENSORCONTACT ALLERGENS[SPI.GPROC] Engineering Sciences [physics]/Chemical and Process EngineeringSKIN SENSITIZATIONNUCLEOPHILIC AMINO ACIDS[SDV.IDA]Life Sciences [q-bio]/Food engineering[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process Engineering[SDV.IDA] Life Sciences [q-bio]/Food engineering
researchProduct

S3 Guidelines: Epicutaneous patch testing with contact allergens and drugs – Short version, Part 2

2019

Epicutaneous patch testing is the diagnostic standard for the detection of allergic contact dermatitis. The present guidelines are aimed at residents and board-certified physicians in the fields of dermatology and allergology as well as other medical specialties involved in establishing the indication for patch testing and its execution in patients with contact dermatitis and other forms of delayed-type hypersensitivity. The target audience also includes other health care providers and insurance funds. Based on a systematic literature search and a formal consensus process (S3), the guidelines were developed by dermatologists in collaboration with pediatricians, occupational medicine physici…

Occupational Medicinemedicine.medical_specialtyConsensusMEDLINETarget audienceDermatologyOccupational medicineImmunocompromised Host030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicinePregnancyHealth caremedicineHumansHypersensitivity DelayedPediatriciansChildAdverse effectAllergic contact dermatitisbusiness.industryAllergensPatch Testsmedicine.disease3. Good healthTest (assessment)Family medicineDermatitis Allergic ContactPractice Guidelines as TopicFemaleNursing StaffbusinessContact dermatitisDermatologistsJDDG: Journal der Deutschen Dermatologischen Gesellschaft
researchProduct

S3 guidelines: Epicutaneous patch testing with contact allergens and drugs – Short version, Part 1

2019

Epicutaneous patch testing is the diagnostic standard for the detection of allergic contact dermatitis. The present guidelines are aimed at residents and board-certified physicians in the fields of dermatology and allergology as well as other medical specialties involved in establishing the indication for patch testing and its execution in patients with contact dermatitis and other forms of delayed-type hypersensitivity. The target audience also includes other health care providers and insurance funds. Based on a systematic literature search and a formal consensus process (S3), the guidelines were developed by dermatologists in collaboration with pediatricians, occupational medicine physici…

Occupational Medicinemedicine.medical_specialtyConsensusMEDLINETarget audienceGuidelines as TopicDermatologyPatch testingOccupational medicineImmunocompromised Host030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicinePregnancyHealth caremedicineHumansHypersensitivity DelayedPediatriciansChildAllergic contact dermatitisbusiness.industryAllergensPatch Testsmedicine.diseaseTest (assessment)Family medicineDermatitis Allergic ContactFemaleNursing StaffbusinessContact dermatitisDermatologistsJDDG: Journal der Deutschen Dermatologischen Gesellschaft
researchProduct

2015

In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force, normal to the finger/object contact, in anticipation of the expected tangential load force, resulting from the combination of the gravitational and the inertial forces. In many contexts, grip force and load force are linearly coupled. A few studies have examined how we adjust the parameters - gain and offset - of this linear relationship. However, the question remains open as to how the brain adjusts grip force regardless of whether load force is generated by different combinations of weight and inerti…

Offset (computer science)Normal forceCognitive Neurosciencemedia_common.quotation_subjectMotor controlInertiaSensory SystemsGravitationCellular and Molecular NeuroscienceEquilibrant ForceNon-contact forceControl theoryFictitious forceSimulationmedia_commonMathematicsFrontiers in Integrative Neuroscience
researchProduct