Search results for "Chemical analysis."
showing 10 items of 308 documents
Atomic Absorption Spectrophotometric Determination of Cobalt in Foods
1985
A method is reported for determination of chromium in foodstuffs. Organic matter is digested with nitric acid, followed by oxidation to Cr(VI) and extraction with methyl isobutyl ketone (MIBK) after HCl addition. Chromium determinations are performed by flame absorption spectroscopy. Absence of interferences is verified and recovery tests are performed on food samples. Quantitation limit (3.8 ng/mL), accuracy (NBS Standard Reference Material 1,573 Tomato Leaves, 4,500 +/- 500 ng/g, found 3,860 +/- 409 ng/g), and precision (CV for vegetable matrix = 9.05%, CV for animal matrix = 14.95%) of the procedure are evaluated.
On-line Chloride Interference Removal for Arsenic Determination in Waste Water and Urine by ICP-MS Using a Modified Capillary
2002
The determination of arsenic in environmental samples like waste waters from industrial effluents and in biological samples like urine is very important due to the toxic nature of some of its species at moderate levels of exposure. The objective of this study was to evaluate the capability of modified anionic capillaries to remove chloride for ICP-MS determination of arsenic, which causes spectral interference due to formation of 40 Ar 35 Cl + . Also high chloride content gives non-spectral interferences. The results indicate that arsenic at a concentration higher than 1 µg L m 1 in a matrix with a chloride content up to 600 mg L m 1 can be accurately determined using a 3-aminopropyltrimeth…
Determination of critical eluent composition for polyethylenglycols using on-line liquid chromatography-Fourier transform infrared spectrometry.
2008
In this work, it has been extended to methanol:water mobile phases, the use of a background correction method for on-line LC-FTIR measurements named Univariate background correction based on the use of a reference spectra matrix (UBC-RSM) and absorbance ratios. It permits to overcome the problem related to spectral changes occurring during the gradient elution, which in the past limited the on-line coupling of LC and FTIR to isocratic elutions. The combined use of the aforementioned background correction technique in on-line isocratic and gradient LC-FTIR, and partial least squares (PLS) has been applied for the search of the critical conditions for polymers. Polyethylenglycol (PEG) has bee…
Adsorptionsvoltammetrische Molybd�nbestimmung in biologischen Proben nach nassem Hochdruckaufschlu\
1989
The transfer of an (known from literature [141 and till now only applied to seawater) adsorption-voltammetric determination of molybdenum with oxine to biological samples, is described. The herewith accomplished changes of base solution resulted simultaneously in an optimization of the method with regard to interpretability and sensitivity. Special care was taken in the problem of decomposition. Best results are obtained with a high-pressure decomposition. Accuracy of analyses is confirmed with trials of recovery also in the biological matrix.
Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry
2007
An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…
Solid-Phase Extraction Techniques for Assay of Diuretics in Human Urine Samples
1991
Abstract Solid-phase extraction techniques were evaluated for the treatment of urine samples in the analysis of diuretics before injection into an HP-Hypersyl ODS-C18 column. Six different reversed-phase extraction columns were tested, and the results obtained are compared with those obtained in a classical liquid-liquid extraction with ethyl acetate. The solid-phase extraction procedures are the best overall choice for all the diuretics tested, due to their versatility, the minor time-consuming, and the good recovery percentages obtained. C18 and C8 packings give the highest recoveries for a majority of the diuretics studied. However, CH or PH columns, due to their greater selectivity, can…
Electrothermal Atomic Absorption Spectrometric Diagnosis of Familial Hypercholesterolemia
2000
We have developed a new nonradioactive assay to identify human low-density lipoprotein receptor defects. It is based on the incubation of cultured cells with colloidal gold-LDL conjugates and quantitation of the gold associated with the cells by electrothermal atomic absorption spectrometry. After an oxidative treatment with nitric and hydrochloric acids, the biological matrix interferes neither with the gold recovery nor with the gold measurements, which are linear, at least from 0.15 to 3 ng of gold. When cells expressing a functional LDL receptor are incubated with increasing amounts of colloidal-gold LDL conjugates, the obtained saturation curve parallels that described when [125I]LDL i…
An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.
2002
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…
Error analysis and performance of different retention models in the transference of data from/to isocratic/gradient elution.
2003
The transferability of retention data among isocratic and gradient RPLC elution modes is studied. For this purpose, 16 beta-blockers were chromatographed under both isocratic and gradient elution with acetonitrile-water mobile phases. Taking into account the elution mode where the experimental data come from, and the mode where the retention should be predicted, the following combinations are possible: isocratic predictions from (i) isocratic or (ii) gradient experimental designs; and gradient predictions from (iii) isocratic or (iv) gradient data. Each of these possibilities was checked using three retention models that relate the logarithm of the retention factor: (a) linearly and (b) qua…
Optimization of iron speciation (soluble, ferrous and ferric) in beans, chickpeas and lentils
2001
Abstract A spectrophotometric method with bathophenanthroline for iron determination that makes it possible to differentiate between iron (II) and iron (III) in total soluble iron in legumes (beans, chickpeas and lentils) was optimized. Sample size, volumes of reducing agent and bathophenanthroline were selected. Matrix interferences made it necessary to apply the addition’s method. To check the quality of the method, linearity and precision (RSD%) were determined. A linear response between 0.1 and 1.8 μg Fe/ml in the assay and precision values ranging from 2.1 to 6 for instrumental precision, and from 1.6 to 1.7 and 2.7 to 9.1, for intra- and inter-day assays, respectively were obtained. T…