Search results for "Chloride"
showing 10 items of 1691 documents
Ion mobility spectrometry as a fast analytical tool in benzalkonium chloride homologs determination.
2017
Abstract A novel procedure is proposed for the determination by ion mobility spectrometry (IMS) of C 12 , C 14 and C 16 benzalkonium chloride (BAC) homologs. The proposed method requires minimum sample treatment and the measurement was made in less than one minute. A high sensitivity was obtained for BAC determination by IMS with limit of detection values from 37 to 69 µg L −1 . Accuracy of the proposed methodology was evaluated through the analysis of aqueous and alcoholic samples spiked with BAC at concentration levels from 0.002% to 20% (w/v), providing recovery values from 91% to 104%. BAC was determined in sanitary alcohols, nasal sprays, postharvest products, algaecides, and treated s…
Silver based sensors from CD for chloride ions detection
2021
This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this tech…
Flow spectrophotometric determination of ammonium ion
1999
Abstract A flow procedure is proposed for the determination of ammonium ion. The sample in basic medium is forced through a solid-phase reactor containing immobilized AgCl on polymeric pearl beads. The released Ag + , complexed with the ammonia, gives a blue ternary complex with the aid of bromopyrogallol red and 1,10-phenanthroline which is spectrophotometrically monitored at 636 nm. The calibration graph is linear over the range 1–20 μg ml −1 ammonium ion, detection limit ( s / n = 3) 0.35 μg ml −1 and relative standard deviation (slope) 1.9 % ( n = 7). The sample throughput is 48 h −1 . The influence of foreign compounds is studied and the procedure is applied to ammonium ion determi…
Urine polyamines determination using dansyl chloride derivatization in solid-phase extraction cartridges and HPLC
1999
The derivatization of biogenic amines such as putrescine, cadaverine, spermidine and spermine with dansyl chloride in solid phase extraction cartridges is described. Different types of filling materials were tested in order to have the highest retention of the different analytes. The best results were obtained by using C18 cartridges. The optimal conditions were: amine solution buffered at pH 12, 2 mM dansyl chloride (acetone-bicarbonate solution 20 mM (pH 9-9.5), 2 + 3 v/v) as reagent concentration, room temperature and 30 min reaction time. The developed procedure was applied to the determination of these polyamines in urine samples from healthy controls and cancer patients using HPLC wit…
A tandem-flow assembly for the chemiluminometric determination of hydroquinone
2003
A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…
Flow‐Injection Chemiluminescent Determination of Thiamine in Pharmaceutical Samples by On‐line Photodegradation
2004
Abstract A simple, sensitive, and precise method for the determination of thiamine hydrochloride in a flow‐injection system is described. The method is based on the UV irradiation of thiamine in acid medium. Then, the photo‐fragments are oxidized by permanganate in acid medium, and the resultant chemiluminescent intensity is measured. The optimum conditions for the photoreaction and for the chemiluminescence emission were investigated. The method allows the determination of thiamine, over the range 0.05(LOD)–84 mg · l−1, with a throughput of 30 h−1, and a RSD (n, 20) at 20 and 0.5 mg · l−1 of the thiamine level of 2.5 and 1.3%, respectively. The method was applied to pharmaceutical preparat…
Selective determination of ammonium in water based on HPLC and chemiluminescence detection
2005
Abstract A selective and sensitive method has been developed for liquid chromatographic determination of ammonium in water samples. The analyte is derivatized with Dansyl Chloride prior to injection into HPLC. Optimal solution derivatization conditions have been established. The dansyl derivative is separated with the aid of a chromatographic column and post-column mixed with peroxyoxalate (TCPO) and H 2 O 2 in order to perform chemiluminescence detection. The detection limit achieved is 8 μg/L and linear response from 0.027 to 0.750 mg/L of ammonium was obtained. Ammonium ion was determined within 2.4 min under optimum chromatographic conditions. The method is fast, and near 10 derivatized…
Preconcentration and dansylation of aliphatic amines using C18 solid-phase packings
2002
Abstract Precolumn preconcentration and derivatization on solid sorbents (Bond Elut C18 solid-phase extraction cartridges) of low-molecular-mass aliphatic amines in water samples have been performed using dansyl chloride (Dns-Cl) as derivatization reagent. Conditions for analyte preconcentration and derivatization such as volume sample, reagent concentration, time, pH and temperature reaction were optimised. On the basis of these studies a rapid and sensitive method for screening of aliphatic amines in waters is presented. Up to volumes of 5 ml, samples are drawn through the sorbent, the analytes retained are dansylated at basic pH, at 100 °C for 10 min or 85 °C for 15 min. The derivatized …
Micellar modified spectrophotometric determination of nitrobenzenes based upon reduction with tin(II), diazotisation and coupling with the Bratton–Ma…
1997
Abstract Nitrobenzenes, such as the antibiotic chloramphenicol, the vasodilator nicardipine, and the herbicides dinitramin, dinobuton, fenitrothion, methylparathion, oxyfluorfen, parathion, pendimethalin, quintozene, and trifluralin, were determined by using a spectrophotometric method in the visible region (540 nm). The method was based on the reduction of the nitrobenzenes to arylamines with tin(II) chloride, diazotisation of the arylamines and coupling of the diazonium ions with the Bratton–Marshall reagent. The two latter reactions were performed in a micellar medium of sodium dodecyl sulphate. The linear calibration range was 2×10 −6 to 7×10 −5 M ( r >0.999), with limits of detection i…
Spectrophotometric flow injection determination of formetanate and m-aminophenol in water after reaction with p-aminophenol
1992
Abstract An automated procedure has been developed for the determination of formetanate and its metabolite m -aminophenol (MAP) in water samples. MAP can be selectively determined in the presence of formetanate by direct on-line reaction with p -aminophenol and spectrophotometric measurement of the absorbance at 576 nm in the presence of KIO 4 , as oxidizing agent. The method has a limit of detection of 5 × 10 −7 M , it provides a recovery percentage from 95 to 104% and permits one to carry out 120 measurements/hr. The spectrophotometric determination of formetanate must be carried out after a previous hydrolysis to MAP. To determine formetanate in the presence of MAP, two steps are necessa…