Search results for "Coincident"
showing 10 items of 38 documents
Pion electroproduction in the 3He(e,é π+)3H reaction at intermediate energies
1997
Abstract The differential coincident pion electroproduction cross section in the 3 He(e,e π + ) 3 H reaction has been measured with high resolution with the three-spectrometer set-up at the Mainz Microtron (MAMI) electron accelerator. Measurements were performed at the four incident energies E 0 = 855, 675, 600, and 555 MeV at fixed four-momentum transfer Q 2 = 0.045 GeV 2 , with the pions detected in parallel kinematics. This enables a separation of the measured cross section into the transverse and longitudinal structure functions by means of the Rosenbluth method. The experimental data are compared to model calculations, in which the elementary pion production amplitude includes the stan…
Direct measurements of the lifetime of medium-heavy hypernuclei
2018
Abstract The lifetime of a Λ particle embedded in a nucleus (hypernucleus) decreases from that of free Λ decay mainly due to the opening of the Λ N → N N weak decay channel. However, it is generally believed that the lifetime of a hypernucleus attains a constant value (saturation) for medium to heavy hypernuclear masses, yet this hypothesis has been difficult to verify. This paper presents a direct measurement of the lifetime of medium-heavy hypernuclei that were hyper-fragments produced by fission or break-up from heavy hypernuclei initially produced with a 2.34 GeV photon-beam incident on thin Fe, Cu, Ag, and Bi target foils. For each event, fragments were detected in coincident pairs by …
Nucleon transfer via (d,p) using TIARA with a24Ne radioactive beam
2005
NESTER; The first physics results measured using the TIARA array are reported. The reaction $^{24}$Ne(d,p)$^{25}$Ne has been studied in inverse kinematics with a radioactive beam of $^(24)$Ne provided by SPIRAL at GANIL. TIARA is very compact with a high geometrical coverage for charged particles, and is designed specifically for the study of transfer reactions in inverse kinematics, with radioactive beams. From the (d,p) differential cross sections, the ground state of $^{25}$Ne is assigned to have $J^\pi$ = $1/2^+$ and the lowest states with $J^\pi$ = $5/2^+$ and $3/2^+$ are tentatively identified at excitation energies of 1.70 and 2.05 (±0.05) MeV, respectively. Coincident gamma-ray data…
Asymmetric linear Ge(Li)Ge(Li) sum-peak coincidence spectrometer
1972
Abstract An asymmetric linear Ge(Li)Ge(Li) sum-peak coincidence spectrometer configuration has been designed and tested. In this system, the ratio of the gains of two detector-amplifier chains is chosen around 1.2 to 1.3, and the pulse amplitudes or addresses due to coincident events are summed. The simple method introduced involving a single run which results in two spectra (separated according to which detector records the larger energy) appears to be quite useful in γγ coincidence and directional correlation measurements, especially in laboratories where no event-by-event data acquisition hardware are available.
Spectra and correlations of Λ andΛ¯produced in 340-GeV/cΣ−+Cand 260-GeV/cn+Cinteractions
2002
We have measured the production of strange baryons and antibaryons in 340-GeV/c Sigma /sup -/+C and 260-GeV/c n+C interactions. The single x/sub F/ distributions show the expected leading particle effect, and the single p/sub t//sup 2/ distributions show a distinct nonthermal behavior. The x/sub F/ distributions of Lambda - Lambda pairs indicate two different phase space distributions for the two coincident baryons. On the other hand two Lambda 's show identical distributions. Momentum conservation during the formation process may represent a significant source for the observed behavior.
Background radioactivity in the scaler mode technique of the Argo-YBJ detector
2011
""ARGO-YBJ is an extensive air shower detector located at the Yangbajing Cosmic Ray Laboratory (4300 ma.s.l., 606 g cm^−2 atmospheric depth, Tibet, China).. It is made by a single layer of Resistive Plate Chambers. (RPCs, total surface ~ 6700 m^2) grouped into 153 units. called “clusters”. The low energy threshold of the experiment is obtained using the ”scaler operation mode”, counting all the particles hitting the detector without reconstruction of the shower size and arrival direction. For each cluster the signals generated by these particles are put in coincidence in a narrow time window (150 ns) and read by four independent. scaler channels, giving the counting rates of channel. >= 1, …
First coincidences in pre-clinical Compton camera prototype for medical imaging
2003
Abstract Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500 μm thick, 256 pad silicon detector with pad size of 1.4×1.4 mm 2 , combined with a 15×15×1 cm 3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (…
A Ge(Li)Ge(Li) sum-peak (summing coincidence) spectrometer
1970
Abstract The sum-peak spectrometer (also called the integral-bias summing coincidence spectrometer) arrangement earlier developed with NaI(Tl) detectors is extended to Ge(Li) detectors. The integral-bias method in sorting sums of coincident pulse amplitudes is replaced by a set of pulse-height selection windows, which simply and more effectively aid in the analysis of sum-peak complexities associated with the symmetric linear summing procedure employed. A large part of the original information lost in summing of the pulse amplitudes can be retained by simultaneous sorting of the total spectrum into suitable subgroups. The arrangement represents in effect a real-time totalizing spectrometer …
Multimode squeezing of frequency combs
2006
We have developed a full multimode theory of a synchronously pumped type-I optical parametric oscillator. We calculate the output quantum fluctuations of the device and find that, in the degenerate case (coincident signal and idler set of frequencies), significant squeezing is obtained when one approaches threshold from below for a set of well-defined ``supermodes,'' or frequency combs, consisting of a coherent linear superposition of signal modes of different frequencies which are resonant in the cavity.
Secondary electron flight times and tracks in the carbon foil time pick-up detector
2014
Carbon foil time pick-up detectors used in the time-of-flight measurements of MeV energy ions have been studied in connection to time-of-flight-energy spectrometer used for heavy ion elastic recoil detection analysis. In experimental coincident TOF-E data characteristic halos are observed around light element isobars, and the origin of these halos were studied. The experimental data indicated that these halos originate from single electron events occurring before the electron multiplication in the microchannel plate. By means of electron trajectory simulations, this halo effect is explained to originate from single electron, emitted from the carbon foil, hitting the non-active area of the m…