Search results for "Collimator"
showing 10 items of 21 documents
Preliminary assessment of the imaging capability of the YAP–(S)PET small animal scanner in neuroscience
2006
The new and fully engineered version of the YAP–(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4 � 4c m 2 of YAlO3:Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axially � 4c m + transaxially. In PET mode, the volume resoluti…
A prototype of very high resolution small animal PET scanner using silicon pad detectors
2007
Abstract A very high-resolution small animal positron emission tomograph (PET), which can achieve sub-millimeter spatial resolution, is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32×16 array of 1.4×1.4 mm pads readout with four VATAGP3 chips which have 128 channels low-noise self-triggering ASIC in each chip, coincidence units, a source turntable and tungsten slice collimator. The silicon detectors were located edgewise on opposite sides of a 4 cm field-of-view to maximize efficiency. Energy resolution is dominated by electronic noise, which is 0.98% (1.38 keV) FWHM at 140.5…
Search for pairs of highly collimated photon-jets in pp collisions at s=13 TeV with the ATLAS detector
2019
Results of a search for the pair production of photon-jets - collimated groupings of photons - in the ATLAS detector at the Large Hadron Collider are reported. Highly collimated photon-jets can arise from the decay of new, highly boosted particles that can decay to multiple photons collimated enough to be identified in the electromagnetic calorimeter as a single, photonlike energy cluster. Data from proton-proton collisions at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 36.7 fb-1, were collected in 2015 and 2016. Candidate photon-jet pair production events are selected from those containing two reconstructed photons using a set of identification criteria …
Legri Operations. Detectors and Detector Stability
2001
Two years after launch (04.21.97), LEGRI is operating on Minisat-01 in a LEO orbit. The LEGRI detector plane is formed by two type of gamma-ray solid state detectors: HgI2 and CdZnTe. Detectors are embedded in a box containing the FEE and DFE electronics. This box provides an effective detector passive shielding. Detector plane is multiplexed by a Coded Aperture System located at 54 cm and a Ta Collimator with a FCFOV of 22° and 2° angular resolution. The aim of this paper is to summarize the detector behaviour in three different time scales: before launch, during the in-orbit check-out period (IOC), and after two years of routine operation in space. Main results can be summarized as follow…
Measurement of radionuclide activities induced in target components of an IBA CYCLONE 18/9 by gamma-ray spectrometry with HPGe and LaBr3: Ce detector…
2014
Cyclotrons are used worldwide to produce radiopharmaceuticals by proton irradiation of a suitable target. The intense secondary neutron beam generated by proton interactions with the target induce high radionuclide activities in the target assembly parts that may result in an exposure to high dose levels of the operators during maintenance. The main goal of this work is to evaluate gamma-emitting radionuclide activities induced in Havar foils and titanium windows of a target assembly and carousel stripper forks of an IBA CYCLONE 18/9 cyclotron. The knowledge of radionuclide inventory for each component is required by many companies to assess risk for operators before waste handling and disp…
Measurements of integrated direct, diffuse and global ultraviolet-B radiation
2015
Abstract We present the first multiyear set of simultaneous measurements of the global ultraviolet-B radiation and its two components: direct and diffuse. The measurements have been taken with four YES-UVB-1 radiometers: two radiometers to measure the diffuse radiation, one provided with a shadow band and the other with a shadow disk on a Sun tracker; a radiometer to measure the global horizontal radiation; and a Sun-tracking radiometer to measure the direct radiation with an especially designed radiance collimator. The diffuse minute-values measured with both instruments agree within a coefficient correlation of 1.00. The diffuse component represents at least 50% of the global UVB (ultravi…
Compact dielectric reflective elements I Half-sphere concentrators of radially emitted light
1994
Optical designs of aspheric internally reflective concentrators of divergent light emitted within a spatial angle of 2n sr are proposed and discussed. Four types of solid transparent element are considered: the divergence angle reducer, the small-spot illuminator, the point focuser, and the collimator. The output beam aperture in all cases is comparable with the light-source external dimensions. Expressions describing the profiles of beam-transforming surfaces and results from experiments with model devices are presented.
EP-1187: Measurements and Monte Carlo modeling of the back scatter from linac secondary collimator into beam monitor chamber
2013
Baseline design of the filters for the LAD detector on board LOFT
2014
The Large Observatory for X-ray Timing (LOFT) was one of the M3 missions selected for the phase A study in the ESA's Cosmic Vision program. LOFT is designed to perform high-time-resolution X-ray observations of black holes and neutron stars. The main instrument on the LOFT payload is the Large Area Detector (LAD), a collimated experiment with a nominal effective area of ~10 m 2 @ 8 keV, and a spectral resolution of ~240 eV in the energy band 2-30 keV. These performances are achieved covering a large collecting area with more than 2000 large-area Silicon Drift Detectors (SDDs) each one coupled to a collimator based on lead-glass micro-channel plates. In order to reduce the thermal load onto …
Comparison between simulated and observed LHC beam backgrounds in the ATLAS experiment at E beam =4 TeV
2018
Results of dedicated Monte Carlo simulations of beam-induced background (BIB) in the ATLAS experiment at the Large Hadron Collider (LHC) are presented and compared with data recorded in 2012. During normal physics operation this background arises mainly from scattering of the 4 TeV protons on residual gas in the beam pipe. Methods of reconstructing the BIB signals in the ATLAS detector, developed and implemented in the simulation chain based on the FLUKA Monte Carlo simulation package, are described. The interaction rates are determined from the residual gas pressure distribution in the LHC ring in order to set an absolute scale on the predicted rates of BIB so that they can be compared qua…