Search results for "Coma"
showing 10 items of 1084 documents
Knowledge about glaucoma in the unselected population: a German survey.
2002
Purpose To determine the general population's knowledge about glaucoma. Materials and methods A representative survey of the German population was conducted in which 2,742 men and women were interviewed face to face. The sample was matched with the German population for age, sex, education, income, and other factors. Questions were asked concerning the nature, occurrence, possible risk factors, and course of glaucoma. Results Fifty-one percent of the population had an active knowledge of the term "glaucoma" and 75% had a passive knowledge of the term. Of those interviewees with a passive knowledge, glaucoma was thought to be associated with raised intraocular pressure (IOP) by 28% and loss …
Analysis of Autoantibodies Against Human Retinal Antigens in Sera of Patients with Glaucoma and Ocular Hypertension
2008
The aim of this study was to show that complex antibody patterns against retinal antigens in sera of patients with glaucoma, found in previous studies, are autoantibodies against human antigens.Sera of 179 patients were collected at the Department of Ophthalmology (University of Mainz, Germany): non-glaucomatous control patients (n=45), primary open-angle glaucoma (n=45), ocular hypertension (n=44), and normal tension glaucoma patients (n=45). The sera were tested against Western blots of human retinal antigens. IgG antibody patterns were analyzed by multivariate statistical techniques, and some significant antigens were identified by mass spectrometry.All subjects, even healthy ones, showe…
Combined procedure for glaucoma and cataract: A retrospective study
1994
Abstract To ascertain the long-term effects of a triple procedure in the case of coexisting cataract and glaucoma, we did a retrospective study of 93 eyes that had cataract extraction, IOL implantation, and trabeculectomy within a ten-year period. Mean follow-up was 32.4 ± 21.9 months. Mean postoperative intraocular pressure (IOP) was significantly lower than preoperatively, even though fewer medications were being used. One year after surgery, 60% of eyes had a best corrected visual acuity of 20/40 or better with an average improvement of 3.8 Snellen lines. Patients who had had surgery four or more years before the study had the highest percentage of eyes with an IOP exceeding 22 mm Hg. Th…
Prevalence of glaucoma and distribution of intraocular pressure in a population. The Casteldaccia Eye Study.
2009
IOP was measured in 1062 middle-aged and elderly subjects of a small Sicilian town, enrolled in a population based survey. The mean IOP was 15.1 +/- 3.7 mmHg without interocular or sex differences. A small but significant age-dependent increase of IOP was found. Circadian and seasonal influences were recorded: IOP was higher in the morning and in winter. The prevalence of chronic open-angle glaucoma was 1.2%, but it grew to 3.6 if only subjects aged 70 years or more were considered. IOP of 24 mmHg or more was found in 2.7%, while 4.3% of subjects showed IOP of 21 mmHg or more. This survey shows that mean IOP of the Mediterranean population studied is similar to the IOP found in other epidem…
Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension.
2002
Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pat…
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Risk factors of ocular hypertension and glaucoma. The Casteldaccia Eye Study.
1994
A case-control study was planned as a part of the Casteldaccia Eye Study in order to investigate about risk factors of ocular hypertension and glaucoma. Cases were 44 subjects with glaucoma or intraocular pressure of 24 mm Hg or more. Controls were 220 subjects with intraocular pressure of 20 mm Hg or less and no signs of glaucoma. A number of environmental, behavioral, systemic and ocular variables were studied. Among the others we investigated the following: sunlight exposure, smoking, alcohol intake, pregnancies, systemic hypertension, diabetes, use of corticosteroids, refractive status, anterior chamber depth, lens nuclear sclerosis, iris color and texture. After univariate analysis the…
Falsely elevated intraocular pressure due to increased central corneal thickness
1999
PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…
Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.
2012
To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …
Translocation (X;18) in a Biphasic Synovial Sarcoma with Morphologic Features of Neural Differentiation
1998
The authors report a recurred neoplasm showing distinctive histologic, immunophenotypic, and ultrastructural features characteristic of biphasic synovial sarcoma with neural differentiation. The features include areas with a growth pattern of densely packed spindle cells in irregularly intersecting, broad fascicles, diffuse vimentin and HBA 71 immunoreactivity, expression of S-100 protein, and other neural markers. Moreover, areas with glandular structures and cellular expression of cytokeratin and epithelial membrane antigen were noted. Additionally, areas of neural-like growth pattern were positive for neuron-specific enolase, HNK-1, and protein gene product 9.5. Furthermore, cytogenetic …