Search results for "Computer Graphics"

showing 10 items of 530 documents

3D reconstruction techniques made easy: know-how and pictures

2005

Three-dimensional reconstructions represent a visual-based tool for illustrating the basis of three-dimensional post-processing such as interpolation, ray-casting, segmentation, percentage classification, gradient calculation, shading and illumination. The knowledge of the optimal scanning and reconstruction parameters facilitates the use of three-dimensional reconstruction techniques in clinical practise. The aim of this article is to explain the principles of multidimensional image processing in a pictorial way and the advantages and limitations of the different possibilities of 3D visualisation.

medicine.medical_specialtyAudiovisual Aids Computer Graphics Computer-Aided Design Humans Image Processing; Computer-Assisted/*methods Imaging; Three-Dimensional/*methods Motion Pictures as Topic Radiographic Image Interpretation; Computer-Assisted/methods Tomography; X-Ray Computed/methods User-Computer InterfaceMotion PicturesImage processingIterative reconstructionComputer-Assisted/*methods ImagingUser-Computer InterfaceImaging Three-DimensionalAudiovisual Aids Computer Graphics Computer-Aided Design Humans Image ProcessingComputer-Assisted/methods TomographyComputer GraphicsImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingSegmentationThree-Dimensional/*methods Motion Pictures as Topic Radiographic Image InterpretationTomographic reconstructionAudiovisual Aidsbusiness.industry3D reconstructionIndustrial computed tomographyX-Ray Computed/methods User-Computer InterfaceGeneral MedicineVisualizationComputer-Aided DesignRadiographic Image Interpretation Computer-AssistedRadiologybusinessTomography X-Ray Computed3D reconstruction techniquesInterpolation
researchProduct

Primary ciliary dyskinesia assessment by means of optical flow analysis of phase-contrast microscopy images

2014

Primary ciliary dyskinesia implies cilia with defective or total absence of motility, which may result in sinusitis, chronic bronchitis, bronchiectasis and male infertility. Diagnosis can be difficult and is based on an abnormal ciliary beat frequency (CBF) and beat pattern. In this paper, we present a method to determine CBF of isolated cells through the analysis of phase-contrast microscopy images, estimating cilia motion by means of an optical flow algorithm. After having analyzed 28 image sequences (14 with a normal beat pattern and 14 with a dyskinetic pattern), the normal group presented a CBF of 5.2 +/- 1.6 Hz, while the dyskinetic patients presented a 1.9 +/- 0.9 Hz CBF. The cutoff …

medicine.medical_specialtyChronic bronchitisPhase contrast microscopyOptical flowBeat (acoustics)Health InformaticsSensitivity and SpecificityPattern Recognition Automatedlaw.inventionTECNOLOGIA ELECTRONICAPrimary ciliary dyskinesialawOphthalmologyImage Interpretation Computer-AssistedMicroscopymedicineHumansMicroscopy Phase-ContrastRadiology Nuclear Medicine and imagingPrimary ciliary dyskinesiaMicroscopy VideoBronchiectasisRadiological and Ultrasound Technologybusiness.industryCiliumOptical flowActive contoursReproducibility of ResultsAnatomyImage Enhancementmedicine.diseaseComputer Graphics and Computer-Aided DesignCell TrackingSubtraction TechniqueFISICA APLICADABeat frequencyComputer Vision and Pattern RecognitionbusinessMATEMATICA APLICADAAlgorithmsFourier-Mellin transformCiliary Motility Disorders
researchProduct

Variations in acoustical beam properties of intracoronary Doppler catheters.

1993

The limitations of coronary angiography in assessing the functional significance of coronary obstructions is well known. While the critical variable of coronary blood flow cannot be readily measured, intraluminal Doppler sonography offers useful related functional information on blood flow velocity. In order to fully evaluate Doppler signals it is essential to have exact knowledge of the transducer transmission characteristics and of the ultrasound beam topology. In an experimental set-up, the transmitter-receiver characteristics of five commonly used Doppler catheters were investigated. In comparing the beam characteristics we found inhomogeneities in the lateral beam spread. At a penetrat…

medicine.medical_specialtyCoronary DiseaseSignalsymbols.namesakeCoronary CirculationComputer GraphicsMedicineHumansComputer SimulationAngioplasty Balloon CoronaryUltrasonography Interventionalbusiness.industryUltrasoundModels CardiovascularSignal Processing Computer-AssistedBlood flowEquipment DesignLaser Doppler velocimetryEchocardiography DopplerTransducersymbolsUltrasonic sensorRadiologyCardiology and Cardiovascular MedicinebusinessDoppler effectBeam (structure)Blood Flow VelocityBiomedical engineeringCatheterization and cardiovascular diagnosis
researchProduct

CT-Angiographie bei arterieller Verschlußkrankheit: Vergleich von 3 Rekonstruktionsverfahren

1997

Purpose To evaluate different rendering techniques of CT data for the assessment of long vessel segments in peripheral vascular occlusive disease. Material and methods 40 CT angiograms (aortoiliac: n = 20, leg arteries: n = 20) were viewed using three different rendering techniques: 1, maximum intensity projection (MIP); 2, volume rendering (VR); 3, shaded surface display (SSD). CT angiograms were obtained in 6 or 8 projections. Axial cross-section images were analysed using an interactive cine mode. Intraarterial DSA was the standard in all cases. Results The sensitivities for the diagnosis of occlusive disease were 100% (cross-section images), 94% (MIP), 91% (VR) and 93% (SSD). The specif…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industryVascular diseaseVolume renderingIterative reconstructionmedicine.diseaseRendering (computer graphics)Maximum intensity projectionArterial Occlusive DiseasesAngiographyMedicineRadiology Nuclear Medicine and imagingRadiologyTomographybusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Comparative ergonomic workflow and user experience analysis of MRI versus fluoroscopy-guided vascular interventions: an iliac angioplasty exemplar ca…

2014

A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant…

medicine.medical_specialtymedicine.medical_treatmentBiomedical EngineeringHealth InformaticsProtocol analysisImaging phantomWorkflowUser experience designAngioplastymedicineFluoroscopyHumansRadiology Nuclear Medicine and imagingMedical physicsComputer SimulationRetrospective StudiesProtocol (science)medicine.diagnostic_testbusiness.industryAngioplastyGeneral MedicineComputer Graphics and Computer-Aided DesignMagnetic Resonance ImagingComputer Science ApplicationsWorkflowSurgery Computer-AssistedFluoroscopyIliac AneurysmTask analysisSurgeryComputer Vision and Pattern RecognitionRadiologyErgonomicsbusiness
researchProduct

Case-specific performance of MM-PBSA, MM-GBSA, and SIE in virtual screening.

2015

In drug discovery the reliable prediction of binding free energies is of crucial importance. Methods that combine molecular mechanics force fields with continuum solvent models have become popular because of their high accuracy and relatively good computational efficiency. In this research we studied the performance of molecular mechanics generalized Born surface area (MM-GBSA), molecular mechanics Poisson-Boltzmann surface area (MM-PBSA), and solvated interaction energy (SIE) both in their virtual screening efficiency and their ability to predict experimentally determined binding affinities for five different protein targets. The protein-ligand complexes were derived with two different app…

molecular mechanics generalized Born surface areaPhosphodiesterase InhibitorsMolecular Dynamics Simulationta3111Molecular mechanicsMolecular Docking Simulationbeta-LactamasesMolecular dynamicssolvated interaction energyBacterial ProteinsComputational chemistryAldehyde ReductaseDrug DiscoveryMaterials ChemistryHumansHSP90 Heat-Shock ProteinsPhysical and Theoretical ChemistryBeta-Lactamase InhibitorsSpectroscopymolecular mechanics Poisson-Boltzmann surface areaMM-GBSAVirtual screeningBinding SitesChemistryPhosphoric Diester Hydrolasesta1182Hydrogen BondingInteraction energyvirtual screeningComputer Graphics and Computer-Aided DesignMolecular Docking SimulationMM-PBSAModels ChemicalROC CurveSolvent modelsDocking (molecular)Area Under CurveBiological systemReceptors Progesteronebeta-Lactamase InhibitorsHydrophobic and Hydrophilic InteractionsProtein BindingJournal of molecular graphicsmodelling
researchProduct

Fast Techniques for Mosaic Rendering

2005

mosaic cultural heritage computer graphics non photorealistic rendering
researchProduct

Smart Ideas for Photomosaic Rendering

2006

non-photorealistic rendering computer graphics
researchProduct

Problem-Based Learning in Professional Studies from the Physiotherapy Students’ Perspective

2018

The aim of the study was to investigate how physiotherapy students using a problem-based learning approach develop into experts during higher education, and answers the question: How do physiotherapy students at bachelor’s level understand the problem-based learning approach while learning to become professionals? PBL is examined using interpretative phenomenological analysis (IPA) of longitudinal data written by 15 voluntary students from two different higher education institutions and collected during 3.5 years. The main results on the new way of learning strengthen earlier conceptions of the importance of reflection in the learning process. The PBL method activates a reflection process b…

physiotherapy studentAdult and Continuing EducationProfessional studiesfysioterapia030218 nuclear medicine & medical imagingEducation03 medical and health sciences0302 clinical medicineComputingMilieux_COMPUTERSANDEDUCATIONproblem-based learningReflection (computer graphics)Vocational EducationMedical educationongelmalähtöinen oppiminenopiskelijatInformation seeking05 social sciencesPerspective (graphical)Professional development050301 educationHealth and Physical EducationProblem-based learningammatillinen kehitysEducational MethodsPsychology0503 educationprofessional development
researchProduct

Enhanced chain dynamics in loop-sorting-systems by means of layout optimization and a kinematic model of the polygon action

2012

Published version of an article in the journal: Structural and Multidisciplinary Optimization. Also available from the publisher at: http://dx.doi.org/10.1007/s00158-011-0743-7 Poor dynamics owing to polygon action is a known concern in mechanical applications of closed articulated chains. In this paper a kinematic model of the polygon action in large chains of loop-sorting-systems is proposed. Through optimization techniques the chain dynamics is improved by minimizing the polygon action using a parametric model of the track layout as design variables. Three formulations of the kinematic polygon action are tested on an average sized planer tracks layout to find a superior model. Verificati…

polygon actionLoop (graph theory)Mathematical optimizationControl and OptimizationComputer scienceengineeringVDP::Technology: 500::Mechanical engineering: 570SortingKinematicsloop-sorting-systemsComputer Graphics and Computer-Aided DesignAction (physics)Computer Science Applicationsmulti-body dynamicsChain (algebraic topology)Control and Systems EngineeringParametric modelPolygonEngineering design processAlgorithmoptimizationSoftware
researchProduct