Search results for "Computer-aided design"
showing 10 items of 312 documents
A Model for Capturing Product Assembly Information
2005
The important issue of mechanical assemblies has been a subject of intense research over the past several years. Most electromechanical products are assemblies of several components, for various technical as well as economic reasons. This paper provides an object-oriented definition of an assembly model called the Open Assembly Model (OAM) and defines an extension to the NIST Core Product Model (NIST-CPM). The assembly model represents the function, form, and behavior of the assembly and defines both a system level conceptual model and associated hierarchical relationships. The model provides a way for tolerance representation and propagation, kinematics representation, and engineering anal…
Food Tray Sealing Fault Detection in Multi-Spectral Images Using Data Fusion and Deep Learning Techniques
2021
A correct food tray sealing is required to preserve food properties and safety for consumers. Traditional food packaging inspections are made by human operators to detect seal defects. Recent advances in the field of food inspection have been related to the use of hyperspectral imaging technology and automated vision-based inspection systems. A deep learning-based approach for food tray sealing fault detection using hyperspectral images is described. Several pixel-based image fusion methods are proposed to obtain 2D images from the 3D hyperspectral image datacube, which feeds the deep learning (DL) algorithms. Instead of considering all spectral bands in region of interest around a contamin…
AIOC2: A deep Q-learning approach to autonomic I/O congestion control in Lustre
2021
Abstract In high performance computing systems, I/O congestion is a common problem in large-scale distributed file systems. However, the current implementation mainly requires administrator to manually design low-level implementation and optimization, we proposes an adaptive I/O congestion control framework, named AIOC 2 , which can not only adaptively tune the I/O congestion control parameters, but also exploit the deep Q-learning method to start the training parameters and optimize the tuning for different types of workloads from the server and the client at the same time. AIOC 2 combines the feedback-based dynamic I/O congestion control and deep Q-learning parameter tuning technology to …
Statistical atlas based exudate segmentation
2013
Diabetic macular edema (DME) is characterized by hard exudates. In this article, we propose a novel statistical atlas based method for segmentation of such exudates. Any test fundus image is first warped on the atlas co-ordinate and then a distance map is obtained with the mean atlas image. This leaves behind the candidate lesions. Post-processing schemes are introduced for final segmentation of the exudate. Experiments with the publicly available HEI-MED data-set shows good performance of the method. A lesion localization fraction of 82.5% at 35% of non-lesion localization fraction on the FROC curve is obtained. The method is also compared to few most recent reference methods.
Uncommon Suffix Tries
2011
Common assumptions on the source producing the words inserted in a suffix trie with $n$ leaves lead to a $\log n$ height and saturation level. We provide an example of a suffix trie whose height increases faster than a power of $n$ and another one whose saturation level is negligible with respect to $\log n$. Both are built from VLMC (Variable Length Markov Chain) probabilistic sources; they are easily extended to families of sources having the same properties. The first example corresponds to a ''logarithmic infinite comb'' and enjoys a non uniform polynomial mixing. The second one corresponds to a ''factorial infinite comb'' for which mixing is uniform and exponential.
Statistical Performance Analysis of a Fast Super-Resolution Technique Using Noisy Translations.
2014
It is well known that the registration process is a key step for super-resolution reconstruction. In this work, we propose to use a piezoelectric system that is easily adaptable on all microscopes and telescopes for controlling accurately their motion (down to nanometers) and therefore acquiring multiple images of the same scene at different controlled positions. Then a fast super-resolution algorithm \cite{eh01} can be used for efficient super-resolution reconstruction. In this case, the optimal use of $r^2$ images for a resolution enhancement factor $r$ is generally not enough to obtain satisfying results due to the random inaccuracy of the positioning system. Thus we propose to take seve…
Visual Parameter Selection for Spatial Blind Source Separation.
2022
Analysis of spatial multivariate data, i.e., measurements at irregularly-spaced locations, is a challenging topic in visualization and statistics alike. Such data are inteGral to many domains, e.g., indicators of valuable minerals are measured for mine prospecting. Popular analysis methods, like PCA, often by design do not account for the spatial nature of the data. Thus they, together with their spatial variants, must be employed very carefully. Clearly, it is preferable to use methods that were specifically designed for such data, like spatial blind source separation (SBSS). However, SBSS requires two tuning parameters, which are themselves complex spatial objects. Setting these parameter…
Can visualization alleviate dichotomous thinking? Effects of visual representations on the cliff effect
2021
Common reporting styles for statistical results in scientific articles, such as $p$ p -values and confidence intervals (CI), have been reported to be prone to dichotomous interpretations, especially with respect to the null hypothesis significance testing framework. For example when the $p$ p -value is small enough or the CIs of the mean effects of a studied drug and a placebo are not overlapping, scientists tend to claim significant differences while often disregarding the magnitudes and absolute differences in the effect sizes. This type of reasoning has been shown to be potentially harmful to science. Techniques relying on the visual estimation of the strength of evidence have been recom…
Automatable sample fabrication process for pump-probe X-ray holographic imaging
2014
Soft X-ray holography is a recently developed imaging technique with sub-50 nm spatial resolution. Key advantages of this technique are magnetic and elemental sensitivity, compatibility with imaging at free electron laser facilities, and immunity to in-situ sample excitations and sample drift, which enables the reliable detection of relative changes between two images with a precision of a few nanometers. In X-ray holography, the main part of the experimental setup is integrated in the sample, which consequently requires a large number of fabrication steps. Here we present a generic design and an automatable fabrication process for samples suitable, and optimized for, efficient high resolut…
Diffractive optics for quasi-direct space-to-time pulse shaping.
2008
The strong chromatic behavior associated with a conventional diffractive lens is fully exploited to propose a novel optical device for pulse shaping in the femtosecond regime. This device consists of two optical elements: a spatially patterned circularly symmetric mask and a kinoform diffractive lens, which are facing each other. The system performs a mapping between the spatial position of the masking function expressed in the squared radial coordinate and the temporal position in the output waveform. This space-to-time conversion occurs at the chromatic focus of the diffractive lens, and makes it possible to tailor the output central wavelength along the axial location of the output point…