Search results for "Computer-assisted"

showing 10 items of 1186 documents

Heart rate variability and self-control—A meta-analysis

2015

Heart rate variability (HRV) has been suggested as a biological correlate of self-control. Whereas many studies found a relationship between HRV at rest and self-control, effect sizes vary substantially across studies in magnitude and direction. This meta-analysis evaluated the association between HRV at rest and self-control in laboratory tasks, with a particular focus on the identification of moderating factors (task characteristics, methodological aspects of HRV assessment, demographics). Overall, 24 articles with 26 studies and 132 effects (n=2317, mean age=22.44, range 18.4-57.8) were integrated (random effects model with robust variance estimation). We found a positive average effect …

Demographicsmedia_common.quotation_subjectStatistics as TopicModels Psychological050105 experimental psychologySelf-ControlElectrocardiography03 medical and health sciences0302 clinical medicineHeart RateStatisticsVariance estimationHumansMedicineHeart rate variability0501 psychology and cognitive sciencesmedia_commonbusiness.industryGeneral Neuroscience05 social sciencesSignal Processing Computer-AssistedMean agePublication biasSelf-controlRandom effects modelNeuropsychology and Physiological PsychologyMeta-analysisFemaleArousalbusiness030217 neurology & neurosurgeryPsychophysiologyBiological Psychology
researchProduct

Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation

2012

Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…

Dental ImplantsCone beam computed tomographymedicine.medical_specialtyComputer scienceDental Implantation EndosseousCone-Beam Computed Tomographycomputer.software_genreModels DentalPatient Care PlanningSurgeryDental implant surgeryImaging Three-DimensionalDental Prosthesis DesignSurgery Computer-AssistedVoxelPosition (vector)Vertical directionRange (statistics)medicineHumansImplantOral SurgeryFrontal regioncomputerBiomedical engineeringClinical Oral Implants Research
researchProduct

Oral microcirculation observed in vivo by videocapillaroscopy: a review

2009

Capillaroscopy is a non-invasive diagnostic technique that is fundamental in viewing peripheral circulation and in studying microangiopathies. The morphological study of microcirculat ion is of fundamental importance, mainly because the microvascular bed is directly involved in the etiopathogenesis of autoimmune disorders and acute and chronic inflammatory pathological conditions. The value of capillaroscopic investigation as a diagnostic means in cases of peripheral microcirculation disorders has been confirmed by numerous studies. Other studies used capillaroscopic investigations to evaluate microcirculation damage not as a complication of disease (diabetes), but as its initial stage, and…

Dental ImplantsPathologymedicine.medical_specialtyMicroscopy Videobusiness.industryMouth MucosaBurning Mouth SyndromeAutoimmune DiseasesMicroscopic AngioscopyMicrocirculationMicrovascular Bedmedicine.anatomical_structureIn vivoPeripheral microcirculationMicrovesselsImage Processing Computer-AssistedHumansMedicineOral mucosaMouth DiseasesbusinessGeneral Dentistryoral capillaroscopy microcirculationJournal of Oral Science
researchProduct

Customised products for orbital wall reconstruction: a systematic review

2021

Abstract The purpose of this systematic review was to critically analyze the recent literature to present the state of the art in customized reconstruction of orbital fractures. Three electronic databases and manual search approaches were used to identify relevant articles. Only studies with a controlled clinical study design were included. Primary outcome was defined as the status of recovery (complete/partial functional and esthetic disturbances). The benefit of intra-surgical navigation should be described. Secondary outcome was defined as the time of surgery, post-surgical events and hospitalization. A total of eight studies out of 552 records identified met the inclusion criteria. Post…

Dental ImplantsTitaniumOrbital wallNavigated surgerymedicine.medical_specialtybusiness.industryClinical study designPlastic Surgery ProceduresSurgical MeshPrimary outcomeSecondary outcomeSurgery Computer-AssistedOtorhinolaryngologyHumansMedicineSurgeryMedical physicsOral SurgerybusinessOrbitOrbital FracturesBritish Journal of Oral and Maxillofacial Surgery
researchProduct

Condylar position indicator and T-scan system II in clinical evaluation of temporomandibular intracapsular disease.

2012

The pathogenesis of temporomandibular joint intracapsular disease (TMJI) is multifactorial and its diagnosis is not easy. In this work authors show two types of clinical analysis: the Condylar Position Indicator (CPI) and T-Scan 2 system.Twenty patients (mean age of 24.5 years) with TMJI problem and 10 healthy matched subjects (mean age: 25.4 years) were selected. Analysis of TMJI was performed on each patient by means of Condylar Position Indicator (CPI) and T-Scan System II tests.Eight patients presented vertical symmetrical condylar distraction greater than healthy subjects (P-value0.001). T-Scan showed a difference of Percentage of Force (POF) not greater than 5%. Seven patients showed …

Dental Occlusion CentricTime FactorsDentistryMandibleMedicineRange of Motion Articulardental modelsHealthy subjectsJaw movementSignal Processing Computer-AssistedCentric relationMethod of analysisCentric RelationTemporomandibular Joint DisordersModels Dentalmedicine.anatomical_structurecomputer-assistedOral SurgerySymptom Assessmenttemporomandibular joint diseaseClinical evaluationAdultcentricDental ArticulatorsAdolescentRotationarticularCondylerange of motionBite ForceYoung Adultstomatognathic systemFacial PainHumanscondylar positionsignal processingbusiness.industryT-Scan systemMandibular Condylecentric relation; condylar position; condylar position indicator; T-Scan system; temporomandibular joint disease; adolescent; adult; bite force; case-control studies; centric relation; dental articulators; dental models; dental occlusion centric; facial pain; humans; jaw relation record; joint capsule; mandible; mandibular condyle; range of motion articular; rotation; signal processing computer-assisted; symptom assessment; temporomandibular joint disorders; time factors; tooth; waxes; young adultdental occlusioncondylar position indicatorTemporomandibular jointT-scan Condylar position indicator temporomandibular intracapsular diseasePosition (obstetrics)OtorhinolaryngologyJaw Relation RecordCase-Control StudiesWaxesSurgerybusinessToothJoint CapsuleJournal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery
researchProduct

Computer-aided system for morphometric mandibular index computation (Using dental panoramic radiographs)

2012

Objective: We propose and validate a computer—aided system to measure three different mandibular indexes: cortical width, panoramic mandibular index and, mandibular alveolar bone resorption index. Study Design: Repeatability and reproducibility of the measurements are analyzed and compared to the manual estimation of the same indexes. Results: The proposed computerized system exhibits superior repeatability and reproducibility rates compared to standard manual methods. Moreover, the time required to perform the measurements using the proposed method is negligible compared to perform the measurements manually. Conclusions: We have proposed a very user friendly computerized method to measure …

Dental panoramicComputer scienceComputationRadiographyDentistryGerodontologyJawsMandibleBone densitometrystomatognathic systemDensitometria òssiaRadiography PanoramicHumansGeneral DentistryRadiographic positioningOrthodonticsReproducibilityMaxil·larsPosicions radiogràfiquesbusiness.industryMandibleOsteoporosiRepeatabilityDental radiology:CIENCIAS MÉDICAS [UNESCO]stomatognathic diseasesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASComputer-aidedComputerized systemOsteoporosisRadiographic Image Interpretation Computer-AssistedSurgeryResearch-ArticlebusinessRadiologia dental
researchProduct

Dental emergency care in Spain during the state of alarm due to COVID-19 pandemic.

2020

Background: The first state of alarm due to COVID-19 in Spain led to limit dental treatment exclusively to emergencies. The objective of the survey was to evaluate the amount and type of emergencies attended during this period, as well as to know how they were solved, and what measures were adopted to carry out dental care in these exceptional circumstances. Material and Methods: This cross-sectional study included 312 Spanish dentists, who fulfilled an online questionnaire with 22 closed questions, divided into five sections regarding to various aspects of professional dental profile and emergency care. Descriptive statistic and Chi-square tests were performed (p<0.05). Results: 75.64% of …

Descriptive statisticsbusiness.industryDental emergencyResearchMEDLINEExceptional circumstancesComputer-assisted web interviewingmedicine.diseaseTriageCommunity and Preventive DentistryALARMstomatognathic diseasesstomatognathic systemPandemicMedicineMedical emergencymedicine.symptombusinessGeneral DentistryUNESCO:CIENCIAS MÉDICASJournal of clinical and experimental dentistry
researchProduct

Monitoring of the action of drugs in melanoma cells by dynamic laser speckle

2014

Abstract. This work presents the development of a protocol based on the dynamic laser speckle designed tomonitor the reaction of cancer cells of line MEL-RC08 to the application of the drug Colcemid in two differentconcentrations: 0.2 and 0.4 μg∕mL. The protocol was designed using the forward scattering approach with anHe-Ne laser of 632.8 nm illuminating the samples, a control, and two variations of Colcemid, being monitoredalong 8 h. The data were analyzed numerically in the time and in the frequency domain, and the results pre-sented the ability of the technique to monitor the action of the drug, particularly Colcemid (0.4 μg∕mL). © 2014Society of Photo-Optical Instrumentation Engineers …

Diagnostic ImagingCellular activityComputer scienceBiomedical Engineeringlaw.inventionBiomaterialschemistry.chemical_compoundSpeckle patternKey pointOpticslawCell Line TumorImage Processing Computer-AssistedmedicineHumansInstrumentation (computer programming)MelanomaAnalysis of VarianceColcemidbusiness.industryLasersMelanomaCell CycleDemecolcineLasermedicine.diseaseAntineoplastic Agents PhytogenicAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialschemistryFrequency domainbusinessBiomedical engineeringJournal of Biomedical Optics
researchProduct

Towards noncontact skin melanoma selection by multispectral imaging analysis

2011

A clinical trial comprising 334 pigmented and vascular lesions has been performed in three Riga clinics by means of multispectral imaging analysis. The imaging system Nuance 2.4 (CRi) and self-developed software for mapping of the main skin chromophores were used. Spe- cific features were observed and analyzed for malignant skin melanomas: notably higher absorbance (especially as the difference of optical density relative to the healthy skin), uneven chromophore distribution over the lesion area, and the possibility to select the "melanoma areas" in the correla- tion graphs of chromophores. The obtained results indicate clinical potential of this technology for noncontact selec- tion of mel…

Diagnostic ImagingMalePathologymedicine.medical_specialtyMultispectral imageBiomedical EngineeringSkin PigmentationOptical densityBiomaterialsLesionHemoglobinsImage Processing Computer-AssistedHumansMedicineMelanomaSkinMelaninsbusiness.industrySpectrum AnalysisMelanomamedicine.diseaseAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsOxyhemoglobinsFemalesense organsmedicine.symptomSkin melanomabusinessSkin lesionSoftwareBiomedical engineeringJournal of Biomedical Optics
researchProduct

3D and multispectral imaging for subcutaneous veins detection.

2009

The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. Experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface are presented. For illumination our system is composed of a mercury arc lamp coupled to a 10nm band-pass spectrometer. A structured lighting system is also coupled to our multispectral system in order to provide 3D information of the p…

Diagnostic ImagingOptics and PhotonicsComputer sciencemedia_common.quotation_subjectMultispectral imageImage processingInfusions Subcutaneouslaw.inventionCatheterizationVeinsAutomationOpticsImaging Three-DimensionallawMedical imagingImage Processing Computer-AssistedContrast (vision)Humansmedia_commonModels StatisticalSpectroscopy Near-InfraredSpectrometerOrientation (computer vision)business.industryEquipment DesignMercuryLinear discriminant analysisImage EnhancementAtomic and Molecular Physics and OpticsSpectrophotometryArc lampbusinessOptics express
researchProduct