Search results for "Computer-assisted"
showing 10 items of 1186 documents
Heart rate variability and self-control—A meta-analysis
2015
Heart rate variability (HRV) has been suggested as a biological correlate of self-control. Whereas many studies found a relationship between HRV at rest and self-control, effect sizes vary substantially across studies in magnitude and direction. This meta-analysis evaluated the association between HRV at rest and self-control in laboratory tasks, with a particular focus on the identification of moderating factors (task characteristics, methodological aspects of HRV assessment, demographics). Overall, 24 articles with 26 studies and 132 effects (n=2317, mean age=22.44, range 18.4-57.8) were integrated (random effects model with robust variance estimation). We found a positive average effect …
Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation
2012
Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…
Oral microcirculation observed in vivo by videocapillaroscopy: a review
2009
Capillaroscopy is a non-invasive diagnostic technique that is fundamental in viewing peripheral circulation and in studying microangiopathies. The morphological study of microcirculat ion is of fundamental importance, mainly because the microvascular bed is directly involved in the etiopathogenesis of autoimmune disorders and acute and chronic inflammatory pathological conditions. The value of capillaroscopic investigation as a diagnostic means in cases of peripheral microcirculation disorders has been confirmed by numerous studies. Other studies used capillaroscopic investigations to evaluate microcirculation damage not as a complication of disease (diabetes), but as its initial stage, and…
Customised products for orbital wall reconstruction: a systematic review
2021
Abstract The purpose of this systematic review was to critically analyze the recent literature to present the state of the art in customized reconstruction of orbital fractures. Three electronic databases and manual search approaches were used to identify relevant articles. Only studies with a controlled clinical study design were included. Primary outcome was defined as the status of recovery (complete/partial functional and esthetic disturbances). The benefit of intra-surgical navigation should be described. Secondary outcome was defined as the time of surgery, post-surgical events and hospitalization. A total of eight studies out of 552 records identified met the inclusion criteria. Post…
Condylar position indicator and T-scan system II in clinical evaluation of temporomandibular intracapsular disease.
2012
The pathogenesis of temporomandibular joint intracapsular disease (TMJI) is multifactorial and its diagnosis is not easy. In this work authors show two types of clinical analysis: the Condylar Position Indicator (CPI) and T-Scan 2 system.Twenty patients (mean age of 24.5 years) with TMJI problem and 10 healthy matched subjects (mean age: 25.4 years) were selected. Analysis of TMJI was performed on each patient by means of Condylar Position Indicator (CPI) and T-Scan System II tests.Eight patients presented vertical symmetrical condylar distraction greater than healthy subjects (P-value0.001). T-Scan showed a difference of Percentage of Force (POF) not greater than 5%. Seven patients showed …
Computer-aided system for morphometric mandibular index computation (Using dental panoramic radiographs)
2012
Objective: We propose and validate a computer—aided system to measure three different mandibular indexes: cortical width, panoramic mandibular index and, mandibular alveolar bone resorption index. Study Design: Repeatability and reproducibility of the measurements are analyzed and compared to the manual estimation of the same indexes. Results: The proposed computerized system exhibits superior repeatability and reproducibility rates compared to standard manual methods. Moreover, the time required to perform the measurements using the proposed method is negligible compared to perform the measurements manually. Conclusions: We have proposed a very user friendly computerized method to measure …
Dental emergency care in Spain during the state of alarm due to COVID-19 pandemic.
2020
Background: The first state of alarm due to COVID-19 in Spain led to limit dental treatment exclusively to emergencies. The objective of the survey was to evaluate the amount and type of emergencies attended during this period, as well as to know how they were solved, and what measures were adopted to carry out dental care in these exceptional circumstances. Material and Methods: This cross-sectional study included 312 Spanish dentists, who fulfilled an online questionnaire with 22 closed questions, divided into five sections regarding to various aspects of professional dental profile and emergency care. Descriptive statistic and Chi-square tests were performed (p<0.05). Results: 75.64% of …
Monitoring of the action of drugs in melanoma cells by dynamic laser speckle
2014
Abstract. This work presents the development of a protocol based on the dynamic laser speckle designed tomonitor the reaction of cancer cells of line MEL-RC08 to the application of the drug Colcemid in two differentconcentrations: 0.2 and 0.4 μg∕mL. The protocol was designed using the forward scattering approach with anHe-Ne laser of 632.8 nm illuminating the samples, a control, and two variations of Colcemid, being monitoredalong 8 h. The data were analyzed numerically in the time and in the frequency domain, and the results pre-sented the ability of the technique to monitor the action of the drug, particularly Colcemid (0.4 μg∕mL). © 2014Society of Photo-Optical Instrumentation Engineers …
Towards noncontact skin melanoma selection by multispectral imaging analysis
2011
A clinical trial comprising 334 pigmented and vascular lesions has been performed in three Riga clinics by means of multispectral imaging analysis. The imaging system Nuance 2.4 (CRi) and self-developed software for mapping of the main skin chromophores were used. Spe- cific features were observed and analyzed for malignant skin melanomas: notably higher absorbance (especially as the difference of optical density relative to the healthy skin), uneven chromophore distribution over the lesion area, and the possibility to select the "melanoma areas" in the correla- tion graphs of chromophores. The obtained results indicate clinical potential of this technology for noncontact selec- tion of mel…
3D and multispectral imaging for subcutaneous veins detection.
2009
The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. Experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface are presented. For illumination our system is composed of a mercury arc lamp coupled to a 10nm band-pass spectrometer. A structured lighting system is also coupled to our multispectral system in order to provide 3D information of the p…