Search results for "Contrast media"

showing 10 items of 323 documents

Influence of myocardial fibrosis and blood oxygenation on heart T2* values in thalassemia patients

2009

Purpose To determine whether T2* measurements quantifying myocardial iron overload in thalassemia patients are influenced by myocardial fibrosis and blood oxygenation. Materials and Methods Multislice multiecho T2* was performed in 94 thalassemia patients in order to quantify myocardial iron overload. The left ventricle was automatically segmented into a 16-segment standardized heart model, and the T2* value on each segment as well as the global T2* were calculated. Delayed enhanced cardiovascular magnetic resonance (DE-CMR) images were obtained to detect myocardial fibrosis. The blood oxygenation was assessed by the noninvasive measurement of partial pressure of oxygen (pO2). Results Myoca…

AdultMalethalassemiamedicine.medical_specialtyIron OverloadAdolescentT2* valueThalassemiaContrast MediaStatistics NonparametricFibrosisInternal medicineblood oxygenationmedicineHumansRadiology Nuclear Medicine and imagingMultisliceChildAgedRetrospective Studiesmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingRetrospective cohort studyMiddle Agedmedicine.diseaseFibrosisOxygenmedicine.anatomical_structureVentriclemyocardial fibrosiCardiologyBlood oxygenationFemaleMyocardial fibrosisbusinessJournal of Magnetic Resonance Imaging
researchProduct

Outcome Analysis and Rational Management of Enhancing Lesions Incidentally Detected on Contrast-Enhanced MRI of the Breast

2003

The purpose of our study was to assess the prevalence, characteristics, and clinical consequence of incidentally detected enhancing lesions on MRI of the breast. SUBJECTS AND METHODS. MRI of the breast (1.0-T scanner, dynamic gadolinium-enhanced T1-weighted three-dimensional gradient-echo sequence, double breast coil) was performed on 1273 women for different indications. Enhancing incidental lesions were defined as enhancing lesions on MRIs that were not expected from findings on the previous conventional imaging. They were classified in five assessment categories using a scoring system based on morphologic and kinetic enhancement characteristics. Detection of enhancing incidental lesions …

Adultmedicine.medical_specialtyScoring systemAdolescentCONTRAST ENHANCED MRIOutcome analysisContrast MediaBreast NeoplasmsOutcome assessmentSeverity of Illness IndexPredictive Value of TestsOutcome Assessment Health CaremedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesProspective cohort studyAgedAged 80 and overIncidental Findingsmedicine.diagnostic_testbusiness.industryFollow up studiesReproducibility of ResultsMagnetic resonance imagingGeneral MedicineMiddle AgedMagnetic Resonance ImagingPredictive value of testsFemaleRadiologybusinessFollow-Up StudiesAmerican Journal of Roentgenology
researchProduct

Case 80: splenosis.

2005

Adultmedicine.medical_specialtybusiness.industryContrast MediaMagnetic Resonance ImagingDiagnosis DifferentialMedicineHumansRadiology Nuclear Medicine and imagingMedical physicsFemalebusinessTomography X-Ray ComputedSplenosisRadiology
researchProduct

A simplified framework to optimize MRI contrast preparation

2018

PURPOSE This article proposes a rigorous optimal control framework for the design of preparation schemes that optimize MRI contrast based on relaxation time differences. METHODS Compared to previous optimal contrast preparation schemes, a drastic reduction of the optimization parameter number is performed. The preparation scheme is defined as a combination of several block pulses whose flip angles, phase terms and inter-pulse delays are optimized to control the magnetization evolution. RESULTS The proposed approach reduces the computation time of B 0 -robust preparation schemes to around a minute (whereas several hours were required with previous schemes), with negligible performance loss. …

AgingMultiple Sclerosis[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingComputer scienceComputationContrast MediaContext (language use)HippocampusCorpus Callosum030218 nuclear medicine & medical imagingReduction (complexity)Magnetics03 medical and health sciences0302 clinical medicineThalamusAlzheimer Disease[INFO.INFO-IM]Computer Science [cs]/Medical ImagingAnimalsHumansComputer SimulationRadiology Nuclear Medicine and imagingPoint (geometry)Gray MatterComputingMilieux_MISCELLANEOUSBlock (data storage)Flexibility (engineering)Phantoms ImagingBrainContrast (statistics)Models TheoreticalOptimal controlMagnetic Resonance ImagingRatsFemaleAlgorithmAlgorithms030217 neurology & neurosurgeryMagnetic Resonance in Medicine
researchProduct

Assessment of Thoracic Aortic Dimensions in an Experimental Setting: Comparison of Different Unenhanced Magnetic Resonance Angiography Techniques Wit…

2008

PURPOSE To compare different unenhanced magnetic resonance angiography (MRA) techniques for quantitative evaluation of vessel lumen in an experimental setting in young pigs whose dimensions allow for a comparison with a pediatric population. MATERIAL AND METHODS Magnetic resonance imaging was performed in 5 healthy ventilated pigs at 1.5 T. Three different electrocardiogram (ECG)-triggered sequences were applied for MRA: [TSE-Db] T2-weighted dark-blood TurboSpinEcho (2.0 x 1.1 x 4 mm3); [trueFISP] 2D-steady-state-free-precession (2.2 x 1.8 x 2 mm3); [NAV] respiratory-gated, T2-prepared 3D-trueFISP (1.3 x 1.3 x 1.3 mm3). ECG-gated-CT angiography (CTA) (16-row CT, 1 mm collimation) served as …

Aortic archmedicine.medical_specialtySwineContrast MediaAorta ThoracicSensitivity and SpecificityMagnetic resonance angiographyElectrocardiographymedicine.arteryAscending aortaAnimalsHumansMedicineThoracic aortaRadiology Nuclear Medicine and imagingcardiovascular diseasesChildComputed tomography angiographymedicine.diagnostic_testbusiness.industryReproducibility of ResultsMagnetic resonance imagingGeneral MedicineDescending aortaAngiographyRadiologyTomography X-Ray ComputedbusinessNuclear medicineMagnetic Resonance AngiographyInvestigative Radiology
researchProduct

Hybrid assemblies based on a gadolinium-containing polyoxometalate and a cationic polymer with spermine side chains for enhanced MRI contrast agents.

2013

Supramolecular assembly: Spherical and stable hybrid assemblies based on a cationic polymer with spermine side chains and an anionic Gd(3+)-containing polyoxometalate cluster (GdW) are prepared by electrostatic interaction. The T1-weighted MRI performance of GdW is enhanced about three times in the assemblies; meanwhile, the assemblies show good biocompatibility, which enables them to be promising candidates for MRI contrast agents.

BiocompatibilityPolymersGadoliniumOrganic ChemistryInorganic chemistryCationic polymerizationchemistry.chemical_elementContrast MediaGadoliniumGeneral ChemistryTungsten CompoundsCombinatorial chemistryMagnetic Resonance ImagingCatalysisSupramolecular assemblychemistryCationsPolyoxometalateSide chainSpermineSelf-assemblyHybrid materialChemistry (Weinheim an der Bergstrasse, Germany)
researchProduct

Highly Loaded Semipermeable Nanocapsules for Magnetic Resonance Imaging.

2017

Magnetic resonance imaging has become an essential tool in medicine for the investigation of physiological processes. The key issues related to contrast agents, i.e., substances that are injected in the body for imaging, are the efficient enhancement of contrast, their low toxicity, and their defined biodistribution. Polyurea nanocapsules containing the gadolinium complex Gadobutrol as a contrast agent in high local concentration and high relaxivity up to 40 s-1 mmol-1 L are described. A high concentration of the contrast agent inside the nanocapsules can be ensured by increasing the crystallinity in the shell of the nanocapsules. Nanocapsules from aliphatic polyurea are found to display hi…

BiodistributionPolymers and PlasticsPolymersGadoliniumMRI contrast agentchemistry.chemical_elementContrast MediaBioengineeringGadolinium02 engineering and technology010402 general chemistry01 natural sciencesNanocapsulesGadobutrolBiomaterialschemistry.chemical_compoundCrystallinityMiceNanocapsulesMaterials ChemistrymedicineOrganometallic CompoundsAnimalsHumansTissue DistributionPolyureaMesenchymal Stem CellsDendrites021001 nanoscience & nanotechnologyMagnetic Resonance Imaging0104 chemical scienceschemistryLiverNanocarriers0210 nano-technologySpleenBiotechnologyBiomedical engineeringmedicine.drugMacromolecular bioscience
researchProduct

Macrophage-Specific Lipid-Based Nanoparticles Improve Cardiac Magnetic Resonance Detection and Characterization of Human Atherosclerosis

2009

ObjectivesWe sought to determine whether gadolinium (Gd)-containing lipid-based nanoparticles (NPs) targeting the macrophage scavenger receptor-B (CD36) improve cardiac magnetic resonance (CMR) detection and characterization of human atherosclerosis.BackgroundGd-containing lipid-based NPs targeting macrophages have improved MR detection of murine atherosclerosis.MethodsGadolinium-containing untargeted NPs, anti-CD36 NPs, and nonspecific Fc-NPs were created. Macrophages were incubated with fluorescent targeted and nontargeted NPs to determine uptake via confocal microscopy and inductively coupled plasma mass spectroscopy (ICP-MS) quantified Gd uptake. Human aortic specimens were harvested at…

CD36 AntigensGadoliniumCD36Contrast Media030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging0302 clinical medicineHeterocyclic CompoundsMacrophageMacrophage Scavenger Receptorhealth care economics and organizationsCells CulturedMicroscopy Confocalmedicine.diagnostic_testbiologyrespiratory systemImmunohistochemistryLipidsMagnetic Resonance ImagingRadiology Nuclear Medicine and imagingcardiovascular systemAutopsyCardiology and Cardiovascular Medicinetherapeuticscirculatory and respiratory physiologyinorganic chemicalsAortic Diseaseschemistry.chemical_elementmacrophageAortic diseaseArticle03 medical and health sciencesPredictive Value of TestsLipid based nanoparticlesmedicineOrganometallic CompoundsHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesbusiness.industryMacrophagesSpectrophotometry Atomictechnology industry and agricultureMagnetic resonance imagingBiological TransportAtherosclerosischemistryCancer researchbiology.proteinNanoparticlesCD36Cardiac magnetic resonancebusinessJACC: Cardiovascular Imaging
researchProduct

Editorial Comment: LI-RADS Provides High Accuracy for Liver Transplant Eligibility in High-Risk Patients.

2022

Carcinoma HepatocellularHepatocellular carcinomaLiver NeoplasmsLI-RADSContrast MediaHumansRadiology Nuclear Medicine and imagingGeneral MedicineSettore MED/36 - Diagnostica Per Immagini E RadioterapiaTomography X-Ray ComputedMagnetic Resonance ImagingLiver TransplantationAJR. American journal of roentgenology
researchProduct

Reliability of extracellular contrast versus gadoxetic acid in assessing small liver lesions using liver imaging reporting and data system v.2018 and…

2022

Background & aims: The diagnostic accuracy of Liver Imaging Reporting and Data System (LI-RADS) v.2018 and European Association for the Study of the Liver (EASL) criteria for the diagnosis of HCC have been widely evaluated, but their reliability should be investigated. We aimed to assess and compare the reliability of LI-RADS v.2018 and EASL criteria for the diagnosis of HCC using MRI with extracellular contrast agents (ECAs) and gadoxetic acid (GA) and determine the effect of ancillary features on LI-RADS reliability. Approach & results: Ten readers reviewed MRI studies of 92 focal liver lesions measuring <3 cm acquired with ECAs and GA <1 month apart from two prospective tri…

Carcinoma HepatocellularHepatology[SDV]Life Sciences [q-bio]Liver NeoplasmsContrast MediaReproducibility of ResultsHepatocellular CarcinomaliverMagnetic Resonance ImagingSensitivity and SpecificityHumansData SystemsProspective StudiesRetrospective Studies
researchProduct