Search results for "Coronary Vessel"

showing 10 items of 112 documents

Myocardial Glutathione Alterations in Acute Coronary Occlusion in the Dog

1987

Glutathione (GSH) decreases in dog mycocardium upon acute coronary occlusion when compared with sham-operated dogs. Total glutathione content (GSHeq = GSH + ZGSSG) remains unchanged throughout the experiment (6 h after surgery) in both sham- and acute coronary occlusion-operated dogs. GSSG and GSH/GSSG ratio increases and decreases respectively in all animals but tends to reach the normal value after 6 h in sham-operated dogs. Both parameters (GSSG and GSH/GSSG ratio) remain altered in acute coronary occlusion-operated ones. This alteration of glutathione status in ischemic myocardium is discussed.

inorganic chemicalsmedicine.medical_specialtyIschemic myocardiumIschemiaCoronary DiseaseBiochemistrychemistry.chemical_compoundDogsfluids and secretionsReference ValuesInternal medicinemedicineAnimalsNormal rangeGlutathione DisulfideTotal glutathionebusiness.industryMyocardiumGlutathionemedicine.diseaseCoronary VesselsGlutathioneKineticschemistryCoronary occlusionAnesthesiaCardiologybusinessFree Radical Research Communications
researchProduct

A rare case of a coronary artery anomaly detected on multidetector computed tomography

2013

An anomalous aortic origin of the coronary artery arising from the opposite sinus with an interarterial course is a rare condition that is associated with a high risk of sudden cardiac death during or after strenuous exertion. We herein report the case of a 47-year-old woman presenting with chest pain, syncope and palpitations who presented with a rare coronary artery anomaly on multidetector computed tomography coronary artery (MDCT-CA) with prospective electrocardiogram (ECG) gating.

medicine.medical_specialtyCoronary Vessel AnomaliesChest painSudden deathSudden cardiac deathElectrocardiographyInternal medicineMultidetector computed tomographyCoronary artery anomalyMultidetector Computed TomographyInternal MedicinePalpitationsMedicineHumanscardiovascular diseasesSinus (anatomy)business.industryGeneral MedicineMiddle Agedmedicine.diseaseSettore MED/11 - Malattie Dell'Apparato Cardiovascolaremedicine.anatomical_structurecardiovascular systemCardiologyExercise TestFemalemedicine.symptombusinesscoronary anomalies coronary computed tomography sudden deathArtery
researchProduct

Management of Coronary Artery Perforation

2020

Coronary artery perforation (CAP) is a rare but potentially life-threatening complication of percutaneous coronary intervention (PCI), however if recognized and managed promptly, its adverse consequences can be minimized. Risk factors for CAP include the use of advanced PCI technique (such as atherectomy and chronic total occlusion interventions) and treatment of severely calcified lesions. There are 3 major types of CAP depending on location: (a) large vessel perforation, (b) distal vessel perforation, and (c) collateral perforation. Large vessel perforation is usually treated with implantation of a covered stent, whereas distal and collateral vessel perforations are usually treated with c…

medicine.medical_specialtyCoronary artery perforationmedicine.medical_treatmentPerforation (oil well)Coronary Artery DiseaseCoil030204 cardiovascular system & hematologyCoronary AngiographyCovered stentCalcificationPercutaneous coronary interventionAtherectomyAnticoagulation03 medical and health sciencesPericardial tamponade0302 clinical medicineHumansMedicine030212 general & internal medicineEmbolizationCoronary Artery Perforationbusiness.industryPercutaneous coronary interventionGeneral Medicinemedicine.diseaseCoronary VesselsSurgeryTreatment OutcomeHeart InjuriesConventional PCIStentsCardiology and Cardiovascular MedicinebusinessComplicationCalcificationCardiovascular Revascularization Medicine
researchProduct

Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease

2020

Abstract Objectives This study sought to compare the performance of a novel drug-coated balloon (DCB) (Elutax SV, Aachen Resonance, Germany), with an everolimus-eluting stent (EES) (Abbott Vascular...

medicine.medical_specialtyDrug coated balloonbusiness.industrymedicine.medical_treatmentStent030204 cardiovascular system & hematologyBalloonlaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawDrug-eluting stentCoronary vesselmedicine030212 general & internal medicineRadiologyCardiology and Cardiovascular MedicinebusinessJACC: Cardiovascular Interventions
researchProduct

Discrimination of early/intermediate and advanced/complicated coronary plaque types by radiofrequency intravascular ultrasound analysis

2002

Radiofrequency intravascular ultrasound (IVUS-RF) analysis, as an extension of conventional IVUS imaging, may provide more accurate plaque discrimination. Thirty-two autopsy atherosclerotic coronary arteries were investigated. Corresponding sectors in different plaques were matched by histologic and RF analysis. Histologic analysis utilized the American Heart Association plaque classification. The backscattered ultrasound RF signal was analyzed by fast-Fourier transform, providing the underlying frequency components of its power spectrum. The normalized backscattered signal power (in decibels [dB]) for frequencies between 15.3 and 40.3 MHz was then measured for plaque discrimination. Advanc…

medicine.medical_specialtyFourier Analysismedicine.diagnostic_testbusiness.industryUltrasoundSpectral densityCoronary Artery DiseaseCoronary VesselsSensitivity and SpecificitySignalCoronary arteriesmedicine.anatomical_structureCoronary plaqueIntravascular ultrasoundCadaverImage Processing Computer-AssistedmedicineHumansRadio frequencyRadiologyCardiology and Cardiovascular MedicinebusinessUltrasonography InterventionalDecibelThe American Journal of Cardiology
researchProduct

Myocardial Protection by Retrograde Cardioplegic Perfusion in the Presence of Acute Coronary Artery Obstruction: An Experimental Study

1992

To investigate retrograde delivery of cardioplegic solutions as a means of enhancing myocardial protection in the presence of coronary artery occlusion, a two-part experimental model was devised. In part 1 (in vitro) the possibility of retroperfusing the entire myocardium during acute occlusion of the left anterior descending artery (LAD) was assessed. In part 2 (in vivo) acute LAD occlusion was performed in dogs, and during 2 hours of aortic cross-clamping crystalline cardioplegic solution was infused at 20-minute intervals. In group I the infusion was antegrade, via the aortic root, and in group II it was retrograde, via the coronary sinus. Thereafter the LAD snare was released and the do…

medicine.medical_specialtyGroup iiContrast MediaBlood PressureCoronary DiseaseCoronary AngiographyPotassium ChlorideDogsBody WaterHypothermia InducedInternal medicineOcclusionmedicineCarnivoraAnimalscardiovascular diseasesCardioplegic SolutionsAortaCoronary sinusCardioprotectionCardiopulmonary Bypassbiologybusiness.industryMyocardiumFissipediaHeartbiology.organism_classificationCoronary VesselsPerfusionmedicine.anatomical_structureAnesthesiaHeart Arrest Inducedcardiovascular systemCardiologyCardiology and Cardiovascular MedicinebusinessPerfusionArteryScandinavian Journal of Thoracic and Cardiovascular Surgery
researchProduct

Coronary microvascular dysfunction

2020

Patients with coronary microvascular dysfunction (CMVD) represent a widespread population and despite the good prognosis, many of them have a poor quality of life with strong limitations in their daily activities because of the angina symptoms. This article summarizes the most frequent clinical presentation pictures like stable and unstable microvascular angina. Main risk factors are discussed, followed by the latest updates on the subject about different pathogenic hypotheses, diagnosis and treatment. Not very well understood microvascular alterations, like slow flow phenomenon and no reflow are discussed and both prognosis and the impact of the disease in the quality of life are analyzed.

medicine.medical_specialtyMyocardial ischemiaMyocardial ischemiaPopulationDisease030204 cardiovascular system & hematologyPoor quality03 medical and health sciences0302 clinical medicineMicrovascular anginaRisk FactorsCoronary CirculationInternal medicineHumansMedicine030212 general & internal medicineAngina symptomseducationeducation.field_of_studybusiness.industryMicrovascular anginaSlow-Flow PhenomenonPrognosisCoronary VesselsHearth failureQuality of LifeCardiologyNo-Reflow PhenomenonCardiology and Cardiovascular Medicinebusiness
researchProduct

Echocardiographic assessment of coronary microvascular dysfunction: Basic concepts, technical aspects, and clinical settings

2021

Abstract Coronary flow reserve is the capacity of the coronary circulation to augment the blood flow in response an increase in myocardial metabolic demands and has a powerful prognostic significance in different clinical situations. It might assess with invasive and noninvasive technique. Transthoracic echocardiography Doppler is an emerging diagnostic technique, noninvasive, highly feasible, safe for patient and physician, without radiation, and able to detect macrovascular and microvascular anomalies in the coronary circulation. This review aims to describe the benefit and limits of echocardiographic assessment of coronary flow reserve.

medicine.medical_specialtyMyocardial ischemiacoronary flow reservecoronary physiologyMyocardial IschemiaReviewsClinical settingsReview030204 cardiovascular system & hematologyDoppler echocardiographycoronary flow reserve; coronary microvascular dysfunction; coronary physiology; Doppler echocardiography; microcirculation; Blood Flow Velocity; Coronary Circulation; Echocardiography; Echocardiography Doppler; Humans; Microcirculation; Coronary Vessels; Myocardial IschemiaMicrocirculation03 medical and health sciencesCoronary circulation0302 clinical medicineCoronary CirculationInternal medicineHumansMedicineRadiology Nuclear Medicine and imaging030212 general & internal medicineCoronary Vesselcoronary microvascular dysfunctionmedicine.diagnostic_testbusiness.industryMicrocirculationDopplerCoronary flow reserveBlood flowCoronary VesselsDoppler echocardiographyEchocardiography Dopplermedicine.anatomical_structureEchocardiographyCardiologyCardiology and Cardiovascular MedicinebusinessCoronary physiologyBlood Flow VelocityHumanEchocardiography
researchProduct

Myocardial infarction with non-obstructive coronary arteries (MINOCA): Intracoronary imaging-based diagnosis and management.

2021

Myocardial infarction with non-obstructive coronary arteries (MINOCA) is defined by clinical evidence of myocardial infarction (MI) with normal or near-normal coronary arteries on angiography. This condition is present in about 5% to 25% of patients presenting with acute coronary syndromes. MINOCA is a working diagnosis. Current guidelines and consensus recommend identification of underlying causes of MINOCA in order to optimize treatment, improve prognosis, and promote prevention of recurrent myocardial infarction. An accurate evaluation of patient history, symptoms and use of invasive and non-invasive imaging should lead to identification of epicardial or microvascular causes of MINOCA an…

medicine.medical_specialtyMyocarditisMyocardial InfarctionContext (language use)Coronary Artery Disease030204 cardiovascular system & hematologyCoronary AngiographyCoronary artery disease03 medical and health sciences0302 clinical medicineMyocardial infarction with non-obstructive coronary arterieRisk FactorsInternal medicineIntravascular ultrasoundmedicineHumans030212 general & internal medicineMyocardial infarctionmedicine.diagnostic_testOptical coherence tomographybusiness.industryTakotsubo syndrome.Intracoronary imagingmedicine.diseaseCoronary VesselsPlaque AtheroscleroticPulmonary embolismCoronary arteriesmedicine.anatomical_structureAngiographyCardiologyIntravascular ultrasoundCardiology and Cardiovascular MedicinebusinessJournal of cardiology
researchProduct

Importance of calibration for diameter and area determination by intravascular ultrasound

1996

Intravascular ultrasound (IVUS) permits quantitative assessment of the lumen diameter and area of coronary arteries. The experimental study was performed to evaluate the accuracy of diameter and area measurements.Lumen quantitation (lumen diameter D and cross-sectional area A) in lucite tubes (lumen diameter 2.5 to 5.7 mm, Plexiglas) was performed using a mechanical IVUS system (HP console, 3.5 F catheter, Boston Scientific, 30 MHz). The influence of fluid type (blood, water and saline solution), fluid temperature (20 degrees C/37 degrees C), catheter to catheter variation, gain setting and ultrasound frequency (12, 20 and 30 MHz) was determined. In blood at 20 degrees C there was a constan…

medicine.medical_specialtyObservational errormedicine.diagnostic_testPhantoms Imagingbusiness.industryUltrasoundLumen (anatomy)Coronary VesselsCoronary arteriesCathetermedicine.anatomical_structureCalibrationIntravascular ultrasoundCirculatory systemHumansMedicineRadiology Nuclear Medicine and imagingRadiologyCardiology and Cardiovascular MedicinebusinessUltrasonography InterventionalCardiac imagingBiomedical engineeringThe International Journal of Cardiac Imaging
researchProduct