Search results for "DETECT"
showing 10 items of 5902 documents
MycoKey Round Table Discussions of Future Directions in Research on Chemical Detection Methods, Genetics and Biodiversity of Mycotoxins
2018
MycoKey, an EU-funded Horizon 2020 project, includes a series of “Roundtable Discussions” to gather information on trending research areas in the field of mycotoxicology. This paper includes summaries of the Roundtable Discussions on Chemical Detection and Monitoring of mycotoxins and on the role of genetics and biodiversity in mycotoxin production. Discussions were managed by using the nominal group discussion technique, which generates numerous ideas and provides a ranking for those identified as the most important. Four questions were posed for each research area, as well as two questions that were common to both discussions. Test kits, usually antibody based, were one major focus of the…
Mechanisms of astringency: Structural alteration of the oral mucosal pellicle by dietary tannins and protective effect of bPRPs
2018
International audience; The interaction of tannins with salivary proteins is involved in astringency. This paper focussed on saliva liningoral mucosae, the mucosal pellicle. Using a cell-based model, the impact of two dietary tannins (EgC and EgCG)on the mucosal pellicle structure and properties was investigated by microscopic techniques. The role of basicProline-Rich-Proteins (bPRPs) in protecting the mucosal pellicle was also evaluated.At low (0.05 mM) tannin concentration, below the sensory detection threshold, the distribution of salivarymucins MUC5B on cells remained unaffected. At 0.5 and 1 mM, MUC5B-tannin aggregates were observed andtheir size increased with tannin concentration and…
Validation and implementation of a commercial real-time PCR assay for direct detection of Candida auris from surveillance samples.
2021
Background Rapid and reliable laboratory methods are required for detecting the nosocomial yeast Candida auris. AurisID® (Olm Diagnostics, England) is a real-time PCR assay approved for detecting C. auris in fungal cultures as well as directly from blood samples, involving a nucleic acid extraction as a prior step. Objectives The purpose of this study is to validate the AurisID® kit for direct detection of C. auris from surveillance samples without prior DNA extraction and to analyze the results of implementing this methodology to our daily laboratory routine protocol for C. auris surveillance studies. Methods Our PCR method using the AurisID® kit was compared with our routine protocol, con…
Imaging through scattering media by microstructured illumination
2016
We describe a method to image objects through scattering media based on microstructured illumination. A spatial light modulator is used to project a set of microstructured light patterns onto the sample. The image is retrieved computationally from the photocurrent fluctuations provided by a detector with no spatial structure. We review several optical setups developed in the last years with different illumination strategies and applied to different turbid media. In particular we introduce a new non-invasive optical system based on a reflection configuration. Our technique does not require coherent light, raster scanning, time-gated detection or a-priori calibration processes. Furthermore it…
Fast UPLC/PDA determination of squalene in Sicilian P.D.O. pistachio from Bronte: Optimization of oil extraction method and analytical characterizati…
2017
Abstract A fast reversed-phase UPLC method was developed for squalene determination in Sicilian pistachio samples that entry in the European register of the products with P.D.O. In the present study the SPE procedure was optimized for the squalene extraction prior to the UPLC/PDA analysis. The precision of the full analytical procedure was satisfactory and the mean recoveries were 92.8 ± 0.3% and 96.6 ± 0.1% for 25 and 50 mg L−1 level of addition, respectively. Selected chromatographic conditions allowed a very fast squalene determination; in fact it was well separated in ∼0.54 min with good resolution. Squalene was detected in all the pistachio samples analyzed and the levels ranged from 5…
Gene-based and semantic structure of the Gene Ontology as a complex network
2012
The last decade has seen the advent and consolidation of ontology based tools for the identification and biological interpretation of classes of genes, such as the Gene Ontology. The information accumulated time-by-time and included in the GO is encoded in the definition of terms and in the setting up of semantic relations amongst terms. This approach might be usefully complemented by a bottom-up approach based on the knowledge of relationships amongst genes. To this end, we investigate the Gene Ontology from a complex network perspective. We consider the semantic network of terms naturally associated with the semantic relationships provided by the Gene Ontology consortium and a gene-based …
A heuristic, iterative algorithm for change-point detection in abrupt change models
2017
Change-point detection in abrupt change models is a very challenging research topic in many fields of both methodological and applied Statistics. Due to strong irregularities, discontinuity and non-smootheness, likelihood based procedures are awkward; for instance, usual optimization methods do not work, and grid search algorithms represent the most used approach for estimation. In this paper a heuristic, iterative algorithm for approximate maximum likelihood estimation is introduced for change-point detection in piecewise constant regression models. The algorithm is based on iterative fitting of simple linear models, and appears to extend easily to more general frameworks, such as models i…
Iron-loaded transferrin (Tf) is detrimental whereas iron-free Tf confers protection against brain ischemia by modifying blood Tf saturation and subse…
2018
Despite transferrin being the main circulating carrier of iron in body fluids, and iron overload conditions being known to worsen stroke outcome through reactive oxygen species (ROS)-induced damage, the contribution of blood transferrin saturation (TSAT) to stroke brain damage is unknown. The objective of this study was to obtain evidence on whether TSAT determines the impact of experimental ischemic stroke on brain damage and whether iron-free transferrin (apotransferrin, ATf)-induced reduction of TSAT is neuroprotective. We found that experimental ischemic stroke promoted an early extravasation of circulating iron-loaded transferrin (holotransferrin, HTf) to the ischemic brain parenchyma.…
A widely used sampling device in colorectal cancer screening programmes allows for large-scale microbiome studies.
2018
We read with interest the article by Passamonti et al ,1 reporting the performance of two different faecal immunochemical tests (FITs) highlighting the importance of standardisation and validation of screening methodologies. Conventionally, laboratory-based FIT is the preferred approach in testing for occult blood in faeces, which includes colorectal cancer screening programmes.2–4 The potential of preserving stable faecal samples in a widely used FIT buffer for microbiome research would enable prospective microbiome studies in generally healthy subjects undergoing colorectal cancer screening. For this purpose, we evaluated faecal sample stability in the commonly used OC-Sensor (Eiken Chemi…
Hepatitis E virus in lettuce and water samples: A method-comparison study
2017
The hepatitis E virus (HEV), which is an increasing cause of acute viral hepatitis in Europe, is a zoonotic virus that is mainly transmitted through contaminated water, consumption of raw or undercooked meat from pigs or wild boar, blood transfusion, and organ transplantation. Although the role of HEV transmission through contaminated produce has not been confirmed, the presence of HEV has been reported in irrigation waters and in vegetables. The present study used a World Health Organization (WHO) international standard and clinical samples to evaluate the performance characteristics of three RT-qPCR assays for detection and quantification of HEV. Two of the evaluated assays provided good …