Search results for "DETECT"
showing 10 items of 5902 documents
On-line in-tube solid phase microextraction coupled to capillary liquid chromatography-diode array detection for the analysis of caffeine and its met…
2019
Abstract In-tube solid phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography with diode array detection provides a simple and fast analytical methodology for the simultaneous quantitation of caffeine and its three primary metabolites (theobromine, paraxanthine and theophylline) in micro samples of serum, saliva and urine matrices. The sample amount required for one analysis was only 2.5 μL of saliva, 6.25 μL of serum or 40 μL of urine, a requirement for its implementation in a hospital laboratory for preterm newborns, where sample availability is a major problem. In standard conditions, 25 μL of diluted saliva or serum (or 100 μL of urine) were processed by IT-S…
Infrared based saliva screening test for COVID‐19
2021
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in an unprecedented need for diagnostic testing that is critical in controlling the spread of COVID-19. We propose a portable infrared spectrometer with purpose-built transflection accessory for rapid point-of-care detection of COVID-19 markers in saliva. Initially, purified virion particles were characterized with Raman spectroscopy, synchrotron infrared (IR) and AFM-IR. A data set comprising 171 transflection infrared spectra from 29 subjects testing positive for SARS-CoV-2 by RT-qPCR and 28 testing negative, was modeled using Monte Carlo Double Cross Validation with 50 randomized test and model sets. The testing se…
The diagnostic role of saliva - A Review
2011
As a diagnostic fluid, saliva offers distinctive advantages over serum because it can be collected non-invasively by individuals, even by patient. Does not require special equipment for collection and storage as unlike blood saliva does not clot. Advantageous for person in whom blood drawing is difficult as in obese and haemophilic patient. Whole saliva used for diagnosis of systemic diseases, because it contains serum constituents. These constituents are derived from the local vasculature of the salivary glands and gingival cervicular fluid.This review examines the diagnostic application of saliva for hereditary disorders, autoimmune diseases, malignant and infectious diseases, and endocri…
Determination of Third-Generation Synthetic Cannabinoids in Oral Fluids.
2020
Abstract A procedure has been developed for the determination of third-generation synthetic cannabinoids in oral fluid samples by using a semi-automated microextraction by packed sorbent (MEPS) procedure and gas chromatography–mass spectrometry (GC–MS) determination. Five synthetic cannabinoids were employed as model compounds 5F-ADB, MMB-CHMICA, THJ-2201, CUMYL-4CN-BINACA and MDMB-CHMCZCA. The most adequate operative conditions for MEPS were evaluated giving quantitative recoveries, from 89 to 124%, in synthetic and field saliva samples spiked with 125 and 250 μg/L of the studied cannabinoids, with the exception of MDMB-CHMCZCA in field saliva samples that provided slightly lower recoverie…
Interest of studying the saliva metabolome, transcriptome and microbiome in screening for pancreatic cancer
2019
Abstract Introduction Pancreatic cancer is a public health problem because its mortality rate is close to its incidence rate. If it were possible to detect this cancer before the onset of symptoms, 5-year survival could reach 75%. Numerous studies have attempted to accelerate the diagnosis to improve survival. Saliva presents interesting characteristics as a fluid for screening and diagnosis. Its many components provide a promising source of constitutive biomarkers with a specific signature of the disease. The aim of this work was to determine the interest of studying the metabolome, the transcriptome and the microbiome of saliva in screening for pancreatic cancer. Materials and methods A r…
A microplate version of the SOS/umu-test for rapid detection of genotoxins and genotoxic potentials of environmental samples
1991
Abstract The umu-microtest is a miniaturized automated short-term test version proposed for screening of umuC-dependent mutagenic potentials of chemicals relevant to environmental pollution, river water and industrial waste water. The test is based on the SOS/umu-test and has been modified in order to allow extensive testing of environmental samples. Genetically engineered Salmonella typhimurium (TA1535/pSK1002) are incubated on a microplate rotor in a sloping position for 2 h with the test samples, followed by addition of fresh culture medium to reach a 10-fold dilution of the incubation medium. 2 h later, the activity of the β-galactosidase, which reflects umuC induction, is determined co…
Analysis of primary aliphatic short-chain monoamines by LC in water samples
2003
Abstract Several derivatization procedures with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) were compared for a rapid analysis of primary aliphatic short-chain monoamines in water samples by HPLC using a LiChorospher analytical separation column (100RP18 125 mm ×4 mm i.d., 5 μm). Both the solution and the solid-support assisted off-line derivatization on C18 SPE cartridges were inadequate options because of beginning degradation processes of the instable isoindol derivatives during their transfer to the analytical column. This problem was precluded with the on-column or solid-support assisted on-line derivatization. In the last mentioned procedure, the derivatization took place in a Hype…
Invariant Feature Matching for Image Registration Application Based on New Dissimilarity of Spatial Features
2016
An invariant feature matching method is proposed as a spatially invariant feature matching approach. Deformation effects, such as affine and homography, change the local information within the image and can result in ambiguous local information pertaining to image points. New method based on dissimilarity values, which measures the dissimilarity of the features through the path based on Eigenvector properties, is proposed. Evidence shows that existing matching techniques using similarity metrics--such as normalized cross-correlation, squared sum of intensity differences and correlation coefficient--are insufficient for achieving adequate results under different image deformations. Thus, new…
Ex vivo measurement reliability using two different cbct scanners for orthodontic purposes
2012
Background There are many cone beam computed tomography (CBCT) scanners available on the market: detector technology, algorithm precision, and scanner settings influence image quality. The aim of this study was to compare the accuracy of linear measurements made on images of the same sample obtained using two different CBCT scanners. Methods Twenty-eight linear measurements between orthodontic anatomical landmarks that were marked with gutta-percha points on a fresh sacrificed lamb head were taken three times. The head was scanned with two CBCT scanners using different scanning parameters. Digital Imaging and Communications in Medicine (DICOM) images were reconstructed and the same measurem…
Thermoelastic stress analysis by means of an infrared scanner and a two-dimensional fast Fourier transform-based lock-in technique
2008
An infrared thermographic experimental set-up has been proposed and evaluated towards the capability to measure thermoelastic-effect-induced temperature changes. A standard infrared thermocamera with a nominal noise-equivalent temperature difference (NETD) resolution of 0.12 K has been employed to measure the temperature from unidirectional glass-reinforced plastic tensile coupons under cyclic sinusoidal loads. The raster scanning mode of the camera single detector produces a time delay in acquiring the signal from two succeeding pixels on the same row, and from consecutive scanned rows. By exploiting the acquired dwell times, it was possible to produce a periodic pattern on the thermal ma…