Search results for "DEVICES"

showing 10 items of 615 documents

The effects of a roundtrip trans-American jet travel on physiological stress, neuromuscular performance, and recovery.

2016

The purpose was to examine the effects of a round trip trans-American jet travel on performance, hormonal alterations, and recovery. Ten matched pairs of recreationally trained men were randomized to either a compression group (COMP) ( n = 10; age: 23.1 ± 2.4 yr; height: 174.8 ± 5.3 cm; body mass: 84.9 ± 10.16 kg; body fat: 15.3 ± 6.0%) or control group (CONT) ( n = 9; age: 23.2 ± 2.3 yr; height: 177.5 ± 6.3 cm; weight: 84.3 ± 8.99 kg; body fat: 15.1 ± 6.4%). Subjects flew directly from Hartford, CT to Los Angeles, CA 1 day before a simulated sport competition (SSC) designed to create muscle damage and returned the next morning on an overnight flight back home. Both groups demonstrated jet…

AdultMalemedicine.medical_specialtyInjury controlPhysiologyAccident preventionPoison controlAthletic Performancecircadian patternspower03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationStress PhysiologicalPhysiology (medical)medicineHumansta315Physiological stressIntermittent Pneumatic Compression DevicesJet Lag SyndromeJet (fluid)TravelSleep qualitymuscular performance030229 sport sciencesRecovery of FunctionHormonesUnited StatesSurgeryCircadian Rhythmendocrine systemMuscle FatigueFemaleneuromuscularPsychologySleepumpieritys030217 neurology & neurosurgeryJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct

Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness

2013

Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…

AdultMalemedicine.medical_specialtyMaterials scienceOptical PhenomenaCoefficient of variationBiomedical EngineeringBlood PressureDerivativePulse Wave AnalysisSignalBiomaterialsYoung AdultVascular StiffnessPhotoplethysmogramPressuremedicineHumansPulse wavePhotoplethysmographyBlood VolumePulse (signal processing)Optical DevicesRepeatabilityAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryTransducerFemaleBiomedical engineeringJournal of Biomedical Optics
researchProduct

Resource utilization and productivity loss in persons with spina bifida—an observational study of patients in a tertiary urology clinic in Germany.

2014

Background and purpose To investigate resource use and burden associated with spina bifida (SB) in Germany. Methods A questionnaire was used to obtain information on SB-related healthcare resource use and assistive technologies used for the last 1 and 10 years. Individuals with SB were recruited at a tertiary specialist clinic. To participate, persons with SB required the cognitive ability to respond or a caregiver to answer questions on their behalf. They could use personal medical charts or other records to answer. The analyses included assessment of frequency and extent of resource use for both time frames. Results Data on 88 persons with a diagnosis of SB were collected (44% female). Du…

AdultMalemedicine.medical_specialtyTertiary Care CentersCost of IllnessGermanyHealth caremedicineHumansSpinal DysraphismHospital daysbusiness.industrySpina bifidaHealth Servicesmedicine.diseaseSelf-Help DevicesHospitalizationNeurologyPhysical therapyUrology clinicResource useObservational studyFemaleNeurology (clinical)businessHealthcare providersResource utilizationEuropean journal of neurology
researchProduct

The role of posterior parietal cortices on prismatic adaptation effects on the representation of time intervals

2013

Previous studies provided evidence of an ascending left-to-right spatial representation of time durations by using a technique affecting high levels of spatial cognition, i.e. prismatic adaptation (PA). Indeed, PA that induced a leftward aftereffect distorted time representation toward an underestimation, while PA that induced a rightward aftereffect distorted time representation toward an overestimation. The present study advances previous findings on the effects of PA on time by investigating the neural basis subtending these effects. We focused on the posterior parietal cortex (PPC) since it is involved in the PA procedure and also in the formulation of the spatial representation of time…

AdultMalemedicine.medical_specialtyTime FactorsCognitive NeuroscienceBisectionPosterior parietal cortexExperimental and Cognitive PsychologyAdaptation (eye)AudiologyFunctional LateralityDevelopmental psychologyTask (project management)Young AdultBehavioral NeuroscienceFigural AftereffectParietal LobeReaction TimemedicineHumansSpatial representationTime representationPrismatic adaptationAnalysis of VarianceSettore M-PSI/02 - Psicobiologia E Psicologia FisiologicaRepresentation (systemics)Spatial cognitionSpatial representation of timeAdaptation PhysiologicalTranscranial Magnetic StimulationDuration (music)Space PerceptionTime PerceptionFemaleEye Protective DevicesPsychologyPhotic StimulationPosterior parietal cortex
researchProduct

Portable PSG for sleep stage monitoring in sports: Assessment of SOMNOwatch plus EEG.

2019

Current sport-scientific studies mostly neglect the assessment of sleep architecture, although the distribution of different sleep stages is considered an essential component influencing an athlete's recovery and performance capabilities. A mobile, self-applied tool like the SOMNOwatch plus EEG might serve as an economical and time-friendly alternative to activity-based devices. However, self-application of SOMNOwatch plus EEG has not been validated against conventional polysomnography (PSG) yet. For evaluation purposes, 25 participants (15 female, 10 male;

AdultMalemedicine.medical_specialtyTime Factorsmedia_common.quotation_subjectPolysomnographySleep REM030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationPolysomnographyElectroencephalographyNeglect03 medical and health sciencesWearable Electronic DevicesYoung Adult0302 clinical medicinePhysical medicine and rehabilitationConfidence IntervalsMedicineHumansOrthopedics and Sports MedicineElectrodesmedia_commonSleep Stagesmedicine.diagnostic_testbusiness.industryElectroencephalography030229 sport sciencesGeneral MedicineSleep LatencySleep architectureAthletesFemaleSleep (system call)Sleep StagesbusinessEuropean journal of sport science
researchProduct

Lead-Related Infective Endocarditis in Latvia: A Single Centre Experience

2019

Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE …

AdultMalemedicine.medical_specialtymedicine.drug_classAntibioticsDiseasemedicine.disease_causeArticleAntibiotic resistanceQuality of lifelead-related infective endocarditisRisk FactorsInternal medicinemedicineHumansAgedRetrospective StudiesAged 80 and overHeart Failurelcsh:R5-920cardiac implantable electronic devicesEndocarditisbusiness.industryArrhythmias CardiacGeneral Medicinecardiac device infectionProstheses and ImplantsMiddle Agedmedicine.diseaseLatviaLRIE mortalityLeadStaphylococcus aureusEchocardiographyInfective endocarditisHeart failureCIED complicationFemalelead-related infective endocarditis; cardiac implantable electronic devices; cardiac device infection; CIED complication; LRIE mortalityCoagulasebusinesslcsh:Medicine (General)Medicina
researchProduct

Force in the Achilles Tendon During Walking With Ankle Foot Orthosis

2009

Background Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design Controlled laboratory study. Methods In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positi…

AdultMalemusculoskeletal diseasesOrthotic Devicesmedicine.medical_specialtyHeelPhysical Therapy Sports Therapy and RehabilitationWalkingElectromyographyAchilles TendonBarefootWeight-BearingYoung AdultPhysical medicine and rehabilitationAnkle/foot orthosismedicineHumansOrthopedics and Sports MedicinePostoperative PeriodFoot OrthosesRuptureAchilles tendonmedicine.diagnostic_testElectromyographyFootbusiness.industryEquipment Designmusculoskeletal systemOrthotic deviceBiomechanical Phenomenabody regionsmedicine.anatomical_structureFemaleAnkleAnklebusinesshuman activitiesThe American Journal of Sports Medicine
researchProduct

Control of intrauterine device insertion with three-dimensional ultrasound: is it the future?

1996

A comparative study was designed to determine whether three-dimensional transvaginal sonography (3D-TVS) offered advantages over two-dimensional transvaginal sonography (2D-TVS) for the identification and location of IUDs in 66 asymptomatic women. Hysteroscopy was performed in cases in which there was a discrepancy between the information obtained by both methods (n = 14). In eight cases (12.2%) the IUD was misidentified with 2D-TVS. In six cases (9.1%) it was not possible to identify the device model with 2D-TVS. In two cases (3.0%) 2D-TVS failed to identify the position of the device. In contrast, all IUDs were identified and located accurately with 3D-TVS. © 1996 John Wiley & Sons, Inc.

AdultThree dimensional ultrasoundmedicine.medical_specialtymedicine.diagnostic_testTransvaginal ultrasonographybusiness.industryResearch methodologyUterusIntrauterine deviceAsymptomaticSurgeryHealth servicesHysteroscopyTransvaginal sonographyMethodsMedicineHumansRadiology Nuclear Medicine and imagingFemaleRadiologymedicine.symptombusinessIntrauterine DevicesUltrasonographyJournal of clinical ultrasound : JCU
researchProduct

Effect of cost on early removal of contraceptive implants: a prospective cohort study

2019

OBJECTIVES To evaluate the effect of the cost of subdermal etonogestrel implant (SEI) on the continuation rate one year after insertion, and to assess the reasons given by users to remove the implant before the expiration date. METHODS Prospective cohort study conducted among 265 women who chose the SEI as a contraceptive method in a sexual and reproductive health center in the eastern region of Spain, between October/2012 and October/2017. The sample was divided into two cohorts depending on the cost of the implant for the user (free-of-charge or requiring partial payment). Kaplan-Meier survival curves were used to compare the cumulative removal rates of free implants with partially paid i…

AdultTime FactorsDentistry03 medical and health sciences0302 clinical medicineHumansMedicinePharmacology (medical)Prospective Studies030212 general & internal medicineProspective cohort studyDevice RemovalSurvival analysisReproductive health030219 obstetrics & reproductive medicineProportional hazards modelbusiness.industryConfoundingObstetrics and GynecologyContraceptionReproductive MedicineSpainCosts and Cost AnalysisFemaleImplantContraceptive implantbusinessUnintended pregnancyIntrauterine DevicesThe European Journal of Contraception & Reproductive Health Care
researchProduct

Effect of an intrauterine device on the gene expression profile of the endometrium.

2006

The human endometrium acquires the ability to allow embryo attachment just for a specific period of time during each menstrual cycle. Understanding of the opposite functional status, referred to as refractoriness, can potentially be used to improve receptivity in infertile patients or as an interceptive approach to prevent gestation.The objective of the study was to analyze the endometrial gene expression profile induced by an inert intrauterine device (IUD) at the time of implantation.We used a microarray containing more than 16,000 cDNAs to investigate the gene expression profile of receptive vs. refractory endometrium in the same women induced by the presence of an IUD. We compared the g…

Adultmedicine.medical_specialtyEndocrinology Diabetes and Metabolismmedia_common.quotation_subjectClinical BiochemistryUterusContext (language use)BiologyEndometriumIntrauterine deviceBiochemistryEndometriumEndocrinologyInternal medicinemedicineHumansEmbryo ImplantationMenstrual cyclemedia_commonOligonucleotide Array Sequence AnalysisRegulation of gene expressionGlycodelinGene Expression ProfilingBiochemistry (medical)medicine.anatomical_structureEndocrinologyGene Expression RegulationIn uteroFemaleIntrauterine DevicesThe Journal of clinical endocrinology and metabolism
researchProduct