Search results for "Dental Implants"
showing 10 items of 281 documents
Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model.
2013
Objectives The aim of this pilot study was to evaluate the vertical osteoconductive and osteointegrative dynamics around titanium–zirconium (TiZr) implants compared to titanium (Ti) implants. Materials and methods In a split-leg design, 12 TiZr-SLActive and 12 Ti-SLActive implants were inserted 3 mm above bone level in the proximal tibia of 12 rabbits. Full periosteal flaps were repositioned to cover the site. Specimens were obtained after 10, 20 and 30 days (each n = 4 per group). Histomorphometric measurements included percentage of linear bone fill (PLF; %), new marginal vertical bone height (VBH; mm) and vertical bone-to-implant contact (vBIC; %). Statistical analysis was performed with…
Candida albicans biofilms on different materials for manufacturing implant abutments and prostheses
2019
[EN] Background: Morphological, physical and chemical properties of both implants and prostheses can determine the biofilm formation on their surface and increase the risk of biological complications. The aim of this study was to evaluate the capacity of biofilm formation of Candida albicans on different materials used to manufacture abutments and prostheses. Material and Methods: Biofilm formation was analyzed on cp grade II titanium, cobalt-chromium alloy and zirconia, silicone, acrylic resin (polymethylmethacrylate) and nano-hybrid composite. Some samples were partially covered with lithium disilicate glass ceramic to study specifically the junction areas. C. albicans was incubated in a …
Development and viability of biofilms grown on experimental abutments mimicking dental implants: an in vivo model
2019
Background To determine whether an experimental abutment mimicking the macro- and microstructure of a dental implant is a suitable method for recovering biofilm, and to describe the features of biofilms formed around such abutments on healthy implants. Material and Methods Experimental abutments were used in 15 patients without peri-implant diseases. After 14 days’ absence of dental hygiene in this area, the abutments were retrieved and analyzed through confocal laser scanning microscopy and scanning electron microscopy. The biofilm formation on the surface of the first 5 abutments was determined by a fluorescence-staining method using SYTO9 nucleic acid stain. In order to study the biofilm…
Soft Tissue Healing at One-Piece Zirconia Implants Compared to Titanium and PEEK Implants of Identical Design: A Histomorphometric Study in the Dog
2013
This study aimed to histomorphometrically evaluate the soft tissue reactions of one-piece zirconia implants versus titanium implants in regard to their insertion depth. Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: an uncoated zirconia implant, a zirconia implant coated with a calcium liberating titanium oxide, a titanium implant, and an experimental implant made of a synthetic material. Using a split-mouth design, they were inserted in both submerged and nonsubmerged healing modes. After 4 months, dissected blocks were stained with toluidine blue to histologically assess the marginal portion of the implant mucosa, apical extension of the barr…
On the use of EMI for the assessment of dental implant stability
2014
The achievement and the maintenance of dental implant stability are prerequisites for the long-term success of the osseointegration process. Since implant stability occurs at different stages, it is clinically required to monitor an implant over time, i.e. between the surgery and the placement of the artificial tooth. In this framework, non-invasive tests able to assess the degree of osseointegration are necessary. In this paper, the electromechanical impedance (EMI) method is proposed to monitor the stability of dental implants. A 3D finite element model of a piezoceramic transducer (PZT) bonded to a dental implant placed into the bone was created, considering the presence of a bone- impla…
Osteogenic parameters surrounding trabecular tantalum metal implants in osteotomies prepared via osseodensification drilling
2019
Background Surgical fixation of implants into bone for the correction of bone deformities or defects is a traditional approach for skeletal stabilization. Important measures of efficacy of implants include implant stability and osseointegration—the direct interaction between living bone and an implant. Osseointegration depends on successful implant placement and subsequent bone remodeling. This study utilized osseodensification drilling (OD) in a low bone density model using trabecular metal (TM) implants. Material and Methods Three osteotomy sites, Regular, OD-CW (clockwise), and OD-CCW (counterclockwise), were prepared in each ilium of three female sheep. Drilling was performed at 1100rpm…
Influence of different restorative materials on the stress distribution in dental implants
2018
Background To assist clinicians in deciding the most suitable restorative materials to be used in the crowns and abutment in implant rehabilitation. Material and methods For finite element analysis (FEA), a regular morse taper implant was created using a computer aided design software. The implant was inserted at the bone model with 3 mm of exposed threads. An anatomic prosthesis representing a first maxillary molar was modeled and cemented on the solid abutment. Considering the crown material (zirconia, chromium-cobalt, lithium disilicate and hybrid ceramic) and abutment (Titanium and zirconia), the geometries were multiplied, totaling eight groups. In order to perform the static analysis,…
Histological and histomorphometric study using an ultrasonic crestal sinus grafting procedure: a multicenter case study
2016
Background: The aim of this study was to evaluate the efficacy of a hydrodynamic ultrasonic driven transcrestal sinus grafting procedure (Intralift ®, Acteon Company, Bordeaux, France) and the use of a bovine high temperature sintered grafting material in sinus sites with less than 5 mm remaining bone height with no additional autogenous bone in order to create a sufficient recipient site for implants. Material and Methods: 12 patients (16 sinus) in this multicenter case study were included. Using a crestal approach, bone under the sinus was prepared with ultrasonic tips until the Schneiderian membrane was reached. With a trumpet shaped instrument, the Schneiderian membrane was elevated. In…
Accidental displacement and migration of endosseous implants into adjacent craniofacial structures: A review and update
2011
Objectives: Accidental displacement of endosseous implants into the maxillary sinus is an unusual but potential complication in implantology procedures due to the special features of the posterior aspect of the maxillary bone; there is also a possibility of migration throughout the upper paranasal sinuses and adjacent structures. The aim of this paper is to review the published literature about accidental displacement and migration of dental implants into the maxillary sinus and other adjacent structures. Study Design: A review has been done based on a search in the main on-line medical databases looking for papers about migration of dental implants published in major oral surgery, periodon…
Rehabilitation of atrophic maxilla: a review of 101 zygomatic implants
2008
Introduction: Zygomatic implants are a good rehabilitation alternative for upper maxilla with severe bone reabsorption. These implants reduce the need for onlay-type bone grafting in the posterior sectors and for maxillary sinus lift procedures - limiting the use of bone grafts to the anterior zone of the upper jaw in those cases where grafting is considered necessary. Objective: To evaluate the survival of 101 zygomatic implants placed in upper maxilla presenting important bone reabsorption, with a follow-up of 1-72 months. Patients and methods: A retrospective study was made of 101 Zygoma® implants (Nobel Biocare, Göteborg, Sweden) placed in 54 patients with totally edentulous and atrophi…