Search results for "Dentin"
showing 10 items of 266 documents
Osteogenesis imperfecta: a clinical study of the first ten years of life.
1992
One hundred twenty-seven children with osteogenesis imperfecta (O.I.) were studied during the first 10 years of life. According to Sillence, 40 patients were assigned to type I, 39 to type III, and 48 to type IV O.I. Centiles for height, weight, and the annual number of fractures could be established for the different types of O.I. The development of the skeletal changes could be documented for the different forms of the disease. At birth, the skeletal changes were significantly more severe in type III than in type IV patients. During the first 10 years of life the number of fractures, extent of skeletal deformities, and growth retardation did not differ between types III and IV. Only fract…
Dentin wettability enhancement for three irrigating solutions and their effect on push out bond strength of gutta percha / AH Plus
2014
Background: The aim of this study was to investigate the effect of wettability enhancement for 17% EDTA, 2.5% sodium hypochlorite and 7% maleic acid solutions on push out bond strength of gutta percha /AH Plus to root dentin. Materials and Methods: One hundred and eight extracted single rooted human lower premolars were instrumented up to Protaper Universal F5 then irrigated with 3ml of 2.5% NaOCl after each file. Irrigants were prepared and a pilot study for determination of Tween 80 concentration yielding the lowest surface tension value in every solution was conducted. Samples were randomly divided into a control group and two experimental groups (17% EDTA and 7% Maleate), further split …
Bond strength and adhesive interfacial micromorphology of self-adhesive resin cements : effect of reduced times of pre-etching
2019
Background Although acid-etching could increase enamel bond strength of self-adhesive (SA) cements, it may lead to negative effect on dentin. The aim of this study was to assess the effect of shortening of phosphoric acid pre-etching duration on enamel/ dentin shear bond strength (SBS) and interfacial microstructure of Panavia SA Luting Plus (PASA) and Bifix SE (BXSE). Material and Methods For both enamel and dentin, effect of pre-etching time was significant (p<0.001); however, effect of cement brand and the interaction of two factors was significant only for dentin (p≤0.008). Three pre-etching times increased SBS of both cements to enamel and BXSE to dentin. In case of dentin SBS of PASA,…
Comparison of the effect of different surface treatments on the bond strength of different cements with nickel chromium metal alloy: An in vitro study
2017
Background For success of any indirect metal restoration, a strong bond between cement and the intaglio surface of metal is imperative. The aim of this study is to evaluate and compare the effect of different surface treatment on the tensile and shear bond strength of different cements with nickel–chromium alloy. Material and Methods 120 premolars were sectioned horizontally parallel to the occlusal surface to expose the dentin. Wax patterns were fabricated for individual tooth followed by casting them in nickel chromium alloy. 60 samples were tested for tensile bond strength, and the remaining 60 for shear bond strength. The samples were divided into three groups (of 20 samples each) as pe…
Assessment of root canal enlargement using Mtwo and BioRace rotary files.
2014
Objective. To evaluate root canal enlargement following mechanical shaping using 2 nickel titanium rotary systems.Material and Methods. Forty single-rooted teeth were immersed in resin and sectioned perpendicular to the long axis at 4, 8, and 12 mm from the apex. Digital capture of sections was performed before and after canal instrumentation using Mtwo and BioRace instruments. The area increase of endodontic space was calculated by subtraction.Results. The use of both instruments has allowed the removal of great amounts of dentin from the canal walls, even when the endodontic morphology is characterized by awkwardness to reach recesses.Conclusions. Both procedures seem to be valid and no d…
Influence of different photoinitiators on the resistance of union in bovine dentin: Experimental and microscopic study
2021
Background To evaluate in vitro the influence of photoinitiators on the microtensile strength of adhesive systems and composite resins in bovine dentin. Material and Methods Forty dentin obtained from bovine teeth were randomly distributed in four groups (n = 10) according to the different adhesive systems and composite resins used: G1 - AAPS + VAPS (Ambar APS + Vittra APS); G2- AAPS + O (Ambar APS + Opallis); G3 - A + VAPS (Ambar + Vittra APS) and G4 - A + O (Ambar + Opallis). After restoration with the composite, the samples were sectioned to obtain toothpicks that were subjected to the microtensile and nanofiltration test (1.0 mm/min). Results The Kruskal-Wallis test did not show signifi…
Could sonic delivery of bulk-fill resins improve the bond strength and cure depth in extended size class I cavities?
2020
Background The implementation of restorative procedures that guarantee success and optimize clinical time is the target of investigations in Restorative Dentistry. This study aimed to analyze the influence of sonic insertion of bulk-fill (BF) and conventional (C) resin composites on the microtensile bond-strength (µ-TBS) and cure depth (CD) of large and deep class I restorations. Material and Methods Fifty-six healthy human premolars were selected and occlusal cavities (4 x 4 x 3 mm; factor C = 5) were prepared. TC - Tetric N-Ceram (BF), SF - SonicFill (BF), and Z350 - Filtek Z350 XT (C) composite resins were used to restore the cavities, using sonic (S) and non-sonic (NS) insertion techniq…
Effect of different adhesive strategies on the microtensile bond strength of dentin to indirect resin-based composite.
2020
Background To evaluate the microtensile bond strength of indirect resin composite bonded to dentin using five different adhesives strategies. Material and Methods Forty specimens (Solidex) were produced and randomly into five groups with different adhesives strategies: (G1)- Single Bond Universal + etch + silane + RelyX Ultimate, (G2)- Single Bond Universal + silane + RelyX Ultimate, (G3)- Single Bond Universal + etch + RelyX Ultimate, (G4)- Single Bond Universal + RelyX Ultimate, and (G5)-Scotchbond Multi-purpose + RelyX ARC. After cementation the specimens were stored in 100% humidity for 24hours at 37°C. The specimens were sectioned perpendicular to the adhesive interface to obtain beams…
Cytotoxicity of Root Canal Filling Materials to Three Different Human Cell Lines
2001
The aim of this study was to investigate the biological compatibility of five root canal sealers (Sealapex, Endion, Super-EBA, Ketac-Endo, and AH Plus) and regular and calcium hydroxide-based gutta-percha in three different human cell lines. Cultures without root canal sealers were used as controls. Cell growth, cell morphology, cell viability, protein content of the cells, and prostaglandin E 2 (PGE 2 ) release were used as parameters to determine the cytotoxicity of the materials. The protein content of the three cell lines—nasal fibroblasts, gingival fibroblasts, and epithelial tumor cells—was significantly reduced (p ≤ 0.001) by all materials tested. Determinations of PGE 2 release show…
Effect of cavity preparation instruments (oscillating or rotating) on the composite-dentin interface in primary teeth.
2003
Abstract Objectives: To evaluate the effect of preparation of instruments on the interfacial integrity between cavity wall and composite restoration. Methods: Two class II slot preparations were done in 10 primary teeth either with SonicSys® or with a conventional bur. The cavities were filled using an adhesive system. One layer of a flowable composite and one layer of a condensable composite were applied. The specimens were analyzed by confocal laser scanning microscopy. Results: In the SonicSys® group the mean thickness of the hybrid layer was 6.12 (0.60) μm; in the control group it was 6.04 (0.63) μm. The difference was not statistically significant. Two fractures were observed in one to…