Search results for "Detection limit"
showing 10 items of 810 documents
Chromatographic Separation of Cresol Isomers by a β‐Cyclodextrin: Application for the Determination of Volatile Phenols in Alcoholic Beverages
2006
Abstract The chromatographic separation of o‐cresol, m‐cresol, and p‐cresol by using β‐cyclodextrin as a chiral reagent has been studied. Conditions for the chromatographic separation of these isomers by using the cyclodextrin in the mobile phase or bonded in the stationary phase were optimized, and both procedures provided good results for the resolution of the chromatographic peaks. The use of fluorimetric detection (λexc 275 nm λem 300 nm) allows detection and quantification limits of the µg/L for eight studied phenols by using both procedures. The determination of volatile phenols in alcoholic beverages must be carried out using the cyclodextrin in the mobile phase because of the co‐elu…
Determination of the UV filters worldwide authorised in sunscreens by high-performance liquid chromatography
2001
Simultaneous determination of organic UV filters worldwide authorised in sunscreen formulations was performed by HPLC with UV spectrophotometric detection. The filters determined were: benzophenone-4, benzophenone-3, butyl methoxydibenzoylmethane, octyl dimethyl PABA, octyl methoxycinnamate, homosalate and octyl salicylate. A C18 stationary phase and an isocratic mobile phase of ethanol-water-acetic acid (70:29.5:0.5) containing 65.4 mM of hydroxypropyl-beta-cyclodextrin, were used with a flow-rate of 0.6 ml/min. UV measurements were carried out at 313 nm. The time required for the analysis was 20 min and the limits of detection were between 1.5 and 2.3 mg/l. The procedure proposed provides…
Separation and determination of homologues of linear alkylbenzenesulfonates by nonaqueous capillary zone electrophoresis using alkylammonium salts in…
2001
The separation of linear alkylbenzene sulfonates (LAS) by nonaqueous capillary electrophoresis (NACE) using negative polarity, and a buffer containing acetic acid and an alkylamine in nonaqueous ethanol, has been investigated. Several primary, secondary, and tertiary alkylamines with alkyl chains of different length were compared. The solutes travelled against the electroosmotic flow (EOF), and at the same time were braked by association with the alkylamine molecules or with the alkylammonium ions. The best resolution between adjacent LAS homologues (R approximately 2.1), partial isomer resolution in two peaks, and at the same time an excellent repeatability, was obtained with a small dipen…
Flow-injection spectrophotometric determination of arylamines and sulphonamides by diazotization and coupling in a micellar medium
1991
Abstract In a sodium dodecyl sulphate (SDS) micellar solution, the rate of coupling of a diazonium ion with N-(1- naphthyl)ethylenediamine (NED) increases greatly, the protonation of the resulting azo dyes takes place at higher pH values and the dyes are more soluble. These favourable features were applied to the development of a simple flow-injection spectrophotometric procedure for the determination of diazotizable substances of pharmaceutical interest. Limits of detection in the range 0.2–0.5 μg ml−1 (signal-to-noise ratio=3), with relative standard deviation of 0.7–3% (n=3) for 5 μg ml−1 standards, were obtained.
Determination of sulfide in waters by flow-injection solid phase spectrophotometry
2000
A highly sensitive flow injection solid-phase spectrophotometric method was developed for the determination of sulfide in waters. The method is based on the formation of Methylene Blue (MB) by reaction between sulfide and N,N-dimethyl-p-phenylenediamine chloride in presence of Fe(III) in acidic medium. The MB formed was adsorbed on C18 bonded silica, located inside a laboratory-made flow cell, which was placed in the optical path of the spectrophotometer. Analyte retention and detection at 666 nm were performed simultaneously, followed by elution with a mixture of methanol and hydrochloric acid. Several variables of the system, such as amine concentration, acidity of the reaction medium, re…
Some observations on the automation by flow injection analysis of the spectrophotometric determination of amino acids and proteins witho-phthalaldehy…
1992
Automation by flow injection analysis with Spectrophotometric detection of the determination of total amino acids and proteins witho-phthalaldehyde is not straightforward. The use of spectrophotometry, instead of spectrofluorimetry, and of N-acetyl-L-cysteine, instead of the conventional mercaptoethanol is advantageous because of the lower variability of absorptivities with respect to fluorescence yields, and the larger stability of the derivatives. Under adequate working conditions and with leucine as reference, the procedure can be used for the evaluation of total amino acids. A similar procedure is proposed for the analysis of proteins in a sample. Limits of detection are ≈ 1 × 10−5M for…
Arsenic content of Spanish cows' milk determined by dry ashing hydride generation atomic absorption spectrometry.
1994
SummaryThe arsenic content of cows' milk consumed in Spain was determined. A procedure using dry ashing hydride generation atomic absorption spectrometry was developed for the purpose. Experimental conditions for the destruction of organic matter were established and an interference study was carried out. The method developed has a detection limit of 0·1 ng/g, a relative SD of 5%, and a recovery (mean ± CSI) of 100 ± 4%. The accuracy of the method was checked by analysis of a certified sample of IAEA milk powder (mean ± CSI: certified, 4·85 ± 0·32 ng/g; found, 5·04 ± 0·81 ng/g). The proposed procedure was used to analyse cows' milk samples. The extremely low arsenic levels found do not pres…
Selective flow-injection biamperometric determination of sulfur-containing amino acids and structurally related compounds
2001
Abstract A simple and selective flow-injection method for the determination of cysteine and methionine is proposed. The method is based on the reaction of the amino acid with chloramine-T and the subsequent reaction of the excess of chloramine-T with an acidic solution of iodide producing a stoichiometric amount of tri-iodide (diminution of the flow-injection analysis (FIA) peak) which is determined biamperometrically using two platinum electrodes polarized at 100 mV. The calibration graph is linear up to 10 μg ml−1 of cysteine and 30 μg ml−1 of methionine; the limit of detection is 0.06 and 0.1 μg ml−1; the repeatability (also as percent of a series of 70 continuous FIA peaks of 5 μg ml−1 …
Zum metabolismus von dialkyldithiocarbamaten
1974
Abstract Metabolism dialkyldithiocarbamates. I. Determination of amines using a reaction with isocyanates followed by gas chromatographic identification of the urea derivatives formed. N,N′-Di- and N,N′,N′-trisubstituted areas, formed by the reaction of amines with isocyanates, e.g. tert. -butyl isocyanate or 3-trifluoromethylphenyl isocyanate, are useful derivatives for the gas chromatographic analysis of primary and secondary amines. The separation is carried out at temperatures between 70 and 130° on liquid phases such as silicone OV-101 and silicone OV-17. With nitrogen and electron capture detectors the detection limit is 10 10 g. Trace analysis of simple primary and secondary amines i…
The PAH composition of surface sediments from Stagnone coastal lagoon, Marsala (Italy)
2006
Abstract This paper examines the presence, distribution, nature and sources of 22 Aromatic Hydrocarbons (PAHs), which are important environmentally and toxicologically, in sediments from the Stagnone coastal lagoon at Marsala (Italy). Analysis was performed by gas chromatography/mass spectrometry (GC/MS) with selected ion monitoring (SIM). The total concentration of polycyclic aromatic hydrocarbons ranged from 72 to 18381 μg/kg of dry matrix. The relative standard deviation (RSD) of the replicates on the concentrations of individual compounds ranged from 5% to 20%. The accuracy of method was estimated by analyzing “blank” samples added of known quantities of analytes and the recover percent…