Search results for "Detection limit"
showing 10 items of 810 documents
Enhanced chemiluminescent determination of chloramphenicol and related nitro compounds by ‘on-line’ photochemical reaction
2000
The viability of tandem photochemical reaction-chemiluminescence detection was studied for a heterogeneous family of nitro compounds using chloramphenicol as a test substance. The 'on-line' chemical photodegradation of chloramphenicol was performed in a flow injection assembly by using a photoreactor consisting of a 725 cm x 0.5 mm id piece of PTFE tubing coiled around an 8 W low-pressure mercury lamp. Photodegraded chloramphenicol was detected by oxidizing photo-fragments from the parent compound and their subsequent reaction with a luminol-Co(II) system. The calibration graph was linear up to 3 x 10(-5) mol l-1 chloramphenicol, the limit of detection was 3 x 10(-9) mol l-1, the relative s…
Gamma irradiation of graphene quantum dots with ethylenediamine: Antioxidant for ion sensing
2020
Due to the low consumption of chemicals, the absence of toxic residual side products, the procedure simplicity and time-saving aspects, gamma irradiation offers advantages over the classical chemical protocols. We successfully employed gamma irradiation in order to introduce N-atoms in Graphene Quantum Dots (GQDs). By irradiating GQDs water dispersions in the presence of isopropyl alcohol and ethylenediamine, at doses of 25, 50 and 200 kGy, we attached amino groups onto GQDs in a single synthetic step. At the same time, a chemical reduction is achieved, too. Selected conditions induced incorporation of N-atoms within GDQs atomic lattice (around 3 at%), at all applied doses. Additionally, th…
Guidelines for alkylphenols estimation as alkylphenol polyethoxylates pollution indicator in wastewater treatment plant effluents
2013
A solid-phase microextraction coupled with a gas chromatography-mass spectrometry method has been developed for the estimation of technical nonylphenol in the presence of other endocrine disruptors, belonging to different chemical families. The profile of the technical nonylphenol found in real samples was tested, and, given that it was similar to that provided for the standard used, reliable results were obtainable. Endocrine disruptors such as 4-n-nonylphenol, bisphenol A and 4-tert-octylphenol were simultaneously analysed. The best conditions achieved enabled the analysis of all analytes using a sample volume of 15 mL or even only 300 μL. Using such a low sample volume reduced the filtra…
Development of pipette tip-based poly(methacrylic acid-co-ethylene glycol dimethacrylate) monolith for the extraction of drugs of abuse from oral flu…
2019
Abstract In this work, a monolithic polymer based on poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MAA-co-EDMA) was prepared inside 200 μL pipette tips for the extraction of drug of abuse from oral fluid samples. After an appropriate surface tip modification, several polymerization mixtures with different monomer/cross-linker ratios, and percentage of porogen were studied. The most appropriate monolith to easily flow organic solvents and oral fluid samples was prepared with a MAA/EDMA ratio of 8:92 wt/wt and dodecanol containing 10 wt% toluene, as porogenic solvent. Parameters affecting the extraction procedure were evaluated and the monolith was characterized in terms of bindin…
Versatile, sensitive liquid chromatography mass spectrometry – Implementation of 10 μm OT columns suitable for small molecules, peptides and proteins
2016
AbstractWe have designed a versatile and sensitive liquid chromatographic (LC) system, featuring a monolithic trap column and a very narrow (10 μm ID) fused silica open tubular liquid chromatography (OTLC) separation column functionalized with C18-groups, for separating a wide range of molecules (from small metabolites to intact proteins). Compared to today’s capillary/nanoLC approaches, our system provides significantly enhanced sensitivity (up to several orders) with matching or improved separation efficiency, and highly repeatable chromatographic performance. The chemical properties of the trap column and the analytical column were fine-tuned to obtain practical sample loading capacities…
The use of a European coinage alloy to compare the detection limits of mobile XRF systems. A feasibility study
2007
The investigation of archaeological and historical materials makes use of techniques that, though borrowed from other fields of research and industrial production, frequently have to be 're-invented' because of peculiar characteristics of the analysed objects. Artistic relevance, limited movability, compositional and structural heterogeneity radically change the experimental approach and often require ad hoc designed equipment. These considerations also apply to x-ray fluorescence, especially regarding mobile systems. The extensive development and use of mobile spectrometers has produced an extremely diversified context and created the need for common criteria to evaluate their performances…
Ex vivo emission of volatile organic compounds from gastric cancer and non-cancerous tissue
2018
The presence of certain volatile organic compounds (VOCs) in the breath of patients with gastric cancer has been reported by a number of research groups; however, the source of these compounds remains controversial. Comparison of VOCs emitted from gastric cancer tissue to those emitted from non-cancerous tissue would help in understanding which of the VOCs are associated with gastric cancer and provide a deeper knowledge on their generation. Gas chromatography with mass spectrometric detection (GC-MS) coupled with head-space needle trap extraction (HS-NTE) as the pre-concentration technique, was used to identify and quantify VOCs released by gastric cancer and non-cancerous tissue samples c…
Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors
2014
Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 µm) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenating novel substrate-integrated hollow waveguides (iHWG) with a likewise miniaturized preconcentration system. A compact preconcentrator column for sampling isoprene from exhaled breath …
Nanomolar pyrophosphate detection in water and in a self-assembled hydrogel of a simple terpyridine-Zn2+ complex.
2014
A simple terpyridine-Zn(II) complex is shown to act as an efficient and highly selective fluorescent sensor for pyrophosphate in water at physiological pH. The sensor complex showed an unprecedented fluorescence response (∼500 fold increase) and a record nanomolar sensitivity (detectable fluorescent response at 20 nM and LOD ∼ 0.8 nM). It has successfully been used to stain and record confocal fluorescence microscopy images of HeLa cells. Moreover, the complex was found to self-assemble into a hydrogel which was subsequently used to coat disposable paper strips for easy, low-cost detection of pyrophosphate.
Sensitive Monoclonal Antibody-Based Immunoassays for Kresoxim-methyl Analysis in QuEChERS-Based Food Extracts
2014
Kresoxim-methyl is nowadays widely used to combat a diversity of common diseases affecting high-value crops. In this article, we report the development and characterization of two novel immunoassays for the analysis of this pioneer strobilurin fungicide, and for the first time, a validation study with food samples was performed. A direct and an indirect competitive immunoassay based on a new anti-kresoxim-methyl monoclonal antibody were developed for sensitive and specific chemical analysis. Optimized assays showed limits of detection of 0.1 μg/L. Fruit and vegetable samples were extracted with acetonitrile by the QuEChERS procedure and analyzed by the developed immunoassays after a simple …