Search results for "Detectors"
showing 10 items of 2229 documents
Digital pulse-shape analysis with a TRACE early silicon prototype
2014
[EN] A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination. K.; 2014 Elsevier B.V. All rights reserved
A dedicated decay-spectroscopy station for the collinear resonance ionization experiment at ISOLDE
2013
A newdecay-spectroscopystation(DSS)has been developed to be coupled to the collinear resonance ionization spectroscopy (CRIS) beam line at CERN-ISOLDE. The system uses a rotatable wheel with ten 20 mg=cm2 carbon foils as beam implantation sites for the efficient measurement of charged decay products. Silicon detectors are placed on either side of the carbon foil in an optimal geometry to cover a large solid angle for detecting these charged particles. In addition to the silicon detectors at the on-beam axis position, a second pair of off-beam axis detectors are placed at the wheel position 108 deg. away, allowing longer-lived species to be studied. Up to three high purity germanium detector…
A novel Si strip array to investigate reaction and decay mechanisms
2008
Abstract The performance of a novel set-up of double-sided silicon micro-strip detectors (DSSD) developed for the GSI-R3B project (reaction studies with relativistic radioactive beams) is presented. The set-up was used in an experiment aimed at measuring the two-proton decay of 19 Mg. This experiment required to record simultaneously protons and the residual nuclei with good position and energy resolution. Our experimental results show that both protons and heavy ions ranging from Z = 2 up to Z = 12 can be identified with good signal-to-noise ratio and high energy and spatial resolution. This allowed to reconstruct 2- and 3-particle vertices with high precision, opening the possibility to…
Cryogenic operation of silicon detectors
2000
This paper reports on measurements at cryogenic temperatures of a silicon microstrip detector irradiated with 24 GeV protons to a #uence of 3.5]1014 p/cm2 and of a p}n junction diode detector irradiated to a similar #uence. At temperatures below 130 K a recovery of charge collection e$ciency and resolution is observed. Under reverse bias conditions this recovery degrades in time towards some saturated value. The recovery is interpreted qualitatively as
Particle identification with time-of-flight and pulse-shape discrimination in neutron-transmutation-doped silicon detectors
2009
Abstract A method for the identification of energetic charged particles has been investigated based on the employment of pulse-shape discrimination (PSD) in a silicon detector in addition to conventional time-of-flight (ToF) techniques. The method makes use of the fact that, at fixed energy, the particle's velocity, or ToF, is a measure of the particle's mass A while the time structure of the current pulse in a silicon energy detector, used as the ToF stop, permits identification of nuclear charges Z. In the measurements presented here, ToF and PSD methods were applied simultaneously. We used micro-channel plate (MCP) detectors as fast time pick-offs and surface-barrier (SB) n-type Si detec…
Experience with the ALEPH silicon vertex detector
1992
Abstract The ALEPH experiment [1] at LEP is equipped with a vertex detector [2] using two layers of double-sided silicon strip detectors. These detectors allow a real two-dimensional measurement of charged particle tracks. The present (1991) detector has the inner layer at a radius of 6.5 cm and the outer layer at 11.5 cm. The theta angle coverage is ±33° for the inner layer and ±50° for the outer layer. The inner layer is made out of 9 faces with four silicon detectors each, the outer layer has 15 such faces. We use silicon detectors of 5 × 5 cm 2 and 300 μm thickness. The readout pitch is 100 μm at both sides and using capacitive charge division a resolution in the order of 10 μm can be a…
Implantation-decay station for low-energy proton measurements
2013
Abstract We have built an implantation-decay station for β - delayed proton and α decay studies at the focal plane of the Momentum Achromat Recoil Spectrometer (MARS) at the Cyclotron Institute of Texas A&M University. Energetic secondary beams with a small momentum spread are stopped in a controlled manner into a very thin silicon strip detector. In addition, high-purity germanium detectors are installed for γ ray detection. Here we give a description of the setup and the observed performance down to E p ≈ 200 keV using implanted 23 Al and 31 Cl sources.
Silicon detector for a Compton camera in nuclear medical imaging
2002
Electronically collimated gamma ca\-me\-ras based on Com\-pton scattering in silicon pad sensors may improve imaging in nuclear medicine and bio-medical research. The work described here concentrates on the silicon pad detector developed for a prototype Compton camera. The silicon pad sensors are read out using low noise VLSI CMOS chips and novel fast triggering chips. Depending on the application a light weight and dense packaging of sensors and its readout electronics on a hybrid is required. We describe the silicon pad sensor and their readout with the newly designed hybrid. %The silicon detector of a Compton camera %may contain up to $10^5$~analogue channels requiring %a fast and low co…
New gas-filled mode of the large-acceptance spectrometer VAMOS
2010
A new gas-filled operation mode of the large-acceptance spectrometer VAMOS at GANIL is reported. A beam rejection factor greater than 10(10) is obtained for the Ca-40+Sm-150 system at 196 MeV. The unprecedented transmission efficiency for the evaporation residues produced in this reaction is estimated to be around 80% for alpha x n channels and above 95% for x ny p channels. A detailed study of the performance of the gas-filled VAMOS and future developments are discussed. This new operation mode opens avenues to explore the potential of fusion reactions in various kinematics. (C) 2010 Elsevier B.V. All rights reserved.
In-beam study of 253No using the SAGE spectrometer
2017
The heavy actinide nucleus 253No (Z = 102) was studied using the (S)ilicon (A)nd (Ge)rmanium (SAGE) spectrometer allowing simultaneous in-beam $\gamma$ -ray and conversion electron spectroscopy at the accelerator laboratory of the University of Jyvaskyla. Using the recoil-tagging technique, $\gamma$ -electron coincidences have allowed for the extension of the level scheme in the lower-spin region of the yrast band. In addition, internal conversion coefficient (ICC) measurements to establish the multipolarity of transitions have been performed. Measurement of the interband-intraband branching ratios supports the assignment of the Nilsson band-head configuration $9/2^{-}[734]$ assigned in pre…