Search results for "Detectors"

showing 10 items of 2229 documents

Effective field theory search for high-energy nuclear recoils using the XENON100 dark matter detector

2017

International audience; We report on weakly interacting massive particles (WIMPs) search results in the XENON100 detector using a nonrelativistic effective field theory approach. The data from science run II (34  kg×224.6 live days) were reanalyzed, with an increased recoil energy interval compared to previous analyses, ranging from (6.6–240)  keVnr. The data are found to be compatible with the background-only hypothesis. We present 90% confidence level exclusion limits on the coupling constants of WIMP-nucleon effective operators using a binned profile likelihood method. We also consider the case of inelastic WIMP scattering, where incident WIMPs may up-scatter to a higher mass state, and …

WIMP nucleon: scatteringParticle physicsdata analysis methodCosmology and Nongalactic Astrophysics (astro-ph.CO)Physics and Astronomy (miscellaneous)Physics::Instrumentation and DetectorsWIMP[ PHYS.ASTR ] Physics [physics]/Astrophysics [astro-ph]Dark matterchemistry.chemical_elementFOS: Physical sciencesAstrophysics::Cosmology and Extragalactic Astrophysics01 natural sciencesNuclear physicsXENONXenonWIMPstatistical analysis0103 physical sciencesEffective field theoryDark Matter010306 general physicsS030UDMnucleus: recoilPhysicsCoupling constanteffective field theory: nonrelativistic010308 nuclear & particles physicsScatteringDetectorAstrophysics::Instrumentation and Methods for Astrophysicsdark matter: detectorchemistryWeakly interacting massive particlesDirect SearchHigh Energy Physics::ExperimentTPC[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]recoil: energyAstrophysics - Cosmology and Nongalactic Astrophysics
researchProduct

Projected WIMP sensitivity of the XENONnT dark matter experiment

2020

XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to 12.3 ± 0.6 (keV t y)-1 and (2.2± 0.5)× 10−3 (keV t y)-1, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage…

WIMP nucleon: scatteringdata analysis methodCosmology and Nongalactic Astrophysics (astro-ph.CO)Physics - Instrumentation and DetectorsHadronDark matterFOS: Physical sciencesElementary particledark matter: direct detection01 natural sciencesWIMP: dark matterHigh Energy Physics - ExperimentNONuclear physicsHigh Energy Physics - Experiment (hep-ex)XENONPE2_2WIMPPE2_1electron: recoil0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Neutron[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsPE2_4Dark matter experimentComputingMilieux_MISCELLANEOUSactivity reportnucleus: recoilPhysicsxenon: liquid010308 nuclear & particles physicsbackgroundAstronomy and AstrophysicsInstrumentation and Detectors (physics.ins-det)Dark matter experiments dark matter simulationssensitivityBaryonDark matter experimentsDark matter simulationsWeakly interacting massive particlesDark matter experiments; Dark matter simulationsNucleon[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]Astrophysics - Cosmology and Nongalactic AstrophysicsJournal of Cosmology and Astroparticle Physics
researchProduct

Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2

2019

The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…

Wire chambers (MWPCdrift tube13000 GeV-cmsPhysics::Instrumentation and DetectorsmuonsTracking (particle physics)01 natural sciences030218 nuclear medicine & medical imagingHigh Energy Physics - ExperimentSubatomär fysikMWPCHigh Energy Physics - Experiment (hep-ex)Gaseous detectors0302 clinical medicineWire chambersDrift tubesSubatomic Physicsscattering [p p][PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]tracking detectorProportional chambersmomentum resolutionInstrumentationImage resolutionMathematical Physicsdrift tubesPhysicsLarge Hadron ColliderDrift chamberstrack data analysisMuon spectrometersResolution (electron density)DetectorSettore FIS/01 - Fisica SperimentaleATLAS:Mathematics and natural scienses: 400::Physics: 430::Nuclear and elementary particle physics: 431 [VDP]Wire chambers (MWPC Thin-gap chambers drift chambers drift tubes proportional chambers etc)medicine.anatomical_structureCERN LHC Collproportional chambers etc)Gaseous detectors; Muon spectrometers; Particle tracking detectors (gaseous detectors); Wire chambers (MWPC thin-gap chambers drift chambers drift tubes proportional chambers etc)MDT chambersWire chambers (MWPC)LHCcolliding beams [p p]Particle Physics - Experimentp p: scatteringspectrometer [muon]Ciências Naturais::Ciências Físicas530 PhysicsParticle tracking detectors (Gaseous detectors):Ciências Físicas [Ciências Naturais]610FOS: Physical sciencesdrift chamber [muon]gas [monitoring]programming03 medical and health sciencesOpticsAtlas (anatomy)Muon spectrometer0103 physical sciencesCalibrationmedicinemuon: drift chamberGaseous detectorddc:610drift chambersHigh Energy Physicsspatial resolutionMuonScience & Technology010308 nuclear & particles physicsbusiness.industryhep-ex:Matematikk og naturvitenskap: 400::Fysikk: 430::Kjerne- og elementærpartikkelfysikk: 431 [VDP]Thin-gap chamberscalibrationmonitoring: gasExperimental High Energy Physicsbusinessp p: colliding beamsmuon: spectrometerexperimental results
researchProduct

B-MINE, the balloon-borne microcalorimeter nuclear line explorer

2001

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting Ti-44 emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the Ti-44 emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3sigma sensitivity in …

X-ray AstronomyPhysics::Instrumentation and DetectorsSupernovaAstrophysics::High Energy Astrophysical PhenomenaBallonX-ray opticsSNRlaw.inventionAstrophysicTelescopeOpticsSettore FIS/05 - Astronomia E AstrofisicaNTD GermaniumlawMicrocalorimeterBinary starEmission spectrumX-ray OpticSpectral resolutionElectrical and Electronic EngineeringSpectroscopyLine (formation)PhysicsX-ray astronomybusiness.industryCondensed Matter PhysicsSupernovaStarsgamma rayMeasuring instrumentbusinessBalloon
researchProduct

Charge Sharing and Cross Talk Effects in High-Z and Wide-Bandgap Compound Semiconductor Pixel Detectors

2023

Intense research activities have been made in the development of high-Z and wide-bandgap compound semiconductor pixel detectors for the next generation X-ray and gamma ray spectroscopic imagers. Cadmium telluride (CdTe) and cadmium-zinc-telluride (CdZnTe or CZT) pixel detectors have shown impressive performance in X-ray and gamma ray detection from energies of few keV up to 1 MeV. Charge sharing and cross-talk phenomena represent the typical drawbacks in sub-millimeter pixel detectors, with severe distortions in both energy and spatial resolution. In this chapter, we review the effects of these phenomena on the response of CZT/CdTe pixel detectors, with particular emphasis on the current st…

X-ray and gamma ray detectorsCdZnTe detectorsCompound semiconductor detectorsCross talkSpectroscopic X-ray imagingSettore FIS/01 - Fisica SperimentaleCharge sharingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CdTe detectors
researchProduct

Digital Pulse-Processing Techniques for X-Ray and Gamma-Ray Semiconductor Detectors

2017

Over the last decade, digital pulse-processing (DPP) electronics have been widely proposed and used for new generation x- and gamma-ray spectrometers. DPP systems, based on direct digitizing and processing of detector signals, lead to better results than the traditional analog pulse-processing electronics in terms of stability, flexibility, reproducibility, energy resolution, throughput, and dead time. In this chapter, we will review the principles of operation of conventional analog electronic chains for x- and gamma-ray semiconductor detectors, with special emphasis on the benefits of the digital approach. The characteristics of a new real-time DPP system, developed by our group, are disc…

X-ray and gamma ray detectorsMaterials scienceDigital electonicSettore FIS/01 - Fisica SperimentaleElectronic engineeringSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Time to digital conversion
researchProduct

Ballistic Deficit Pulse Processing in Cadmium-Zinc-Telluride Pixel Detectors for High-Flux X-ray Measurements.

2022

High-flux X-ray measurements with high-energy resolution and high throughput require the mitigation of pile-up and dead time effects. The reduction of the time width of the shaped pulses is a key approach, taking into account the distortions from the ballistic deficit, non-linearity, and time instabilities. In this work, we will present the performance of cadmium–zinc–telluride (CdZnTe or CZT) pixel detectors equipped with digital shapers faster than the preamplifier peaking times (ballistic deficit pulse processing). The effects on energy resolution, throughput, energy-linearity, time stability, charge sharing, and pile-up are shown. The results highlight the absence of time instabilities …

X-ray and gamma ray detectorsPhysics::Instrumentation and DetectorsX-RaysBiochemistrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Atomic and Molecular Physics and OpticsCdTe detectorsAnalytical ChemistryZincElectrical and Electronic EngineeringTelluriumInstrumentationCZT detectors; CdTe detectors; X-ray and gamma ray detectorsCZT detectorsCadmiumSensors (Basel, Switzerland)
researchProduct

Filters for X-Ray Detectors on Space Missions

2022

Thin filters and gas-tight windows are used in space to protect sensitive X-ray detectors from out-of-band electromagnetic radiation, low-energy particles, and molecular contamination. Though very thin and made of light materials, filters are not fully transparent to X-rays. For this reason, they ultimately define the detector quantum efficiency at low energies. In this chapter, we initially provide a brief overview of filter materials and specific designs adopted on space experiments with main focus on detectors operating at the focal plane of grazing incidence X-ray telescopes. We then provide a series of inputs driving the design and development of filters for high-energy astrophysics sp…

X-ray filters X-ray detectors Thermal filters Optical blocking filters Filter modeling Filter characterization Filter calibration Space missionsSettore FIS/05 - Astronomia E Astrofisica
researchProduct

Nanocrystalline CaWO$_4$ and ZnWO$_4$ Tungstates for Hybrid Organic-Inorganic X-ray Detectors

2023

The experiment at the DESY PETRA-III synchrotron was performed within project No. I-20211105 EC at the Institute of Solid State Physics, University of Latvia, as the Cen ter of Excellence has received funding from the European Union’s Horizon 2020 Framework Pro gramme H2020-WIDESPREAD-01-2016-2017-TeamingPhase2 under grant agreement No. 739508, project CAMART2.

X-ray sensingCondensed Matter - Materials Sciencehybrid organic–inorganic X-ray detectorsMaterials Science (cond-mat.mtrl-sci)FOS: Physical sciencesGeneral Materials Science600:NATURAL SCIENCES::Physics [Research Subject Categories]Applied Physics (physics.app-ph)Physics - Applied Physicstungstates; hybrid organic–inorganic X-ray detectors; X-ray sensingddc:600tungstates
researchProduct

Time-dependent current-voltage characteristics of Al/p-CdTe/Pt x-ray detectors

2012

Current-voltage (I-V) characteristics of Schottky Al/p-CdTe/Pt detectors were investigated in dark and at different temperatures. CdTe detectors with Al rectifying contacts, very appealing for high resolution x-ray and gamma ray spectroscopy, suffer from bias-induced polarization phenomena which cause current increasing with the time and severe worsening of the spectroscopic performance. In this work, we studied the time-dependence of the I-V characteristics of the detectors, both in reverse and forward bias, taking into account the polarization effects. The I-V measurements, performed at different time intervals between the application of the bias voltage and the measurement of the current…

X-ray spectroscopySchottky contactX-ray and gamma ray detectorsMaterials sciencebusiness.industrySettore FIS/01 - Fisica SperimentaleContact resistanceX-ray detectorGeneral Physics and AstronomySchottky diodeBiasingThermionic emissionSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Settore FIS/03 - Fisica Della MateriaCdTe detectorPolarizationOptoelectronicsGamma spectroscopybusinessPolarization (electrochemistry)Journal of Applied Physics
researchProduct