Search results for "Detectors"
showing 10 items of 2229 documents
A measurement of the neutron to 199Hg magnetic moment ratio
2014
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30).
Annealing study of oxygenated and non-oxygenated float zone silicon irradiated with protons
2003
Abstract Introducing oxygen into the silicon material is believed to improve the radiation hardness of silicon detectors. In this study, oxygenated and non-oxygenated silicon samples were processed and irradiated with 15 MeV protons. In order to speed up the defect reactions after the exposure to particle radiation, the samples were heat treated at elevated temperatures. In this way, the long-term stability of silicon detectors in hostile radiation environment could be estimated. Current–voltage measurements and Surface Photovoltage (SPV) method were used to characterize the samples.
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …
The measurement of impurities in silicon for solar cell production
2012
The power conversion efficiency of solar cells is largely dependent on impurity levels in silicon. In the current investigations two sample preparation methods of silicon had been used before analysis - acid dissolution at atmospheric pressure and pressured microwave assisted technique. Quantification of impurities in solar silicon was done by inductively coupled plasma mass spectrometry and electrothermal atomic spectrometry. Microwave assisted dissolution of solar silicon was more effective compared to the traditional dissolution method on the hot plate, but complete dissolution of impurities and silicon matrix was achieved with a nitric and hydrofluoric acid mixture. The mass of solar si…
Vers une architecture électronique unifiée et zéro temps mort pour l'instrumentation nucléaire
2014
International audience; Dans l'instrumentation nucléaire, et d'autres domaines tels que les applications de la physique des particules, l'analyse de signaux médicaux (Tomographie par Émission de Positons (TEP), Électro-EncéphaloGraphie (EEG)) ou la détection de signaux radar, le signal mesuré est composé d'impulsions dont la date d'arrivée est aléatoire, et dont l'amplitude et la durée sont non déterministes. La grande variété d'applications nécessite de disposer d'une architecture flexible pouvant être aisément reprogrammée. De plus, l'exigence de mesures en temps réel impose de disposer d'une grande capacité de calcul et de bande passante pour la mise en forme et l'extraction des caractér…
Measurement of Atmospheric Neutrino Oscillations at 6–56 GeV with IceCube DeepCore
2018
We present a measurement of the atmospheric neutrino oscillation parameters using three years of data from the IceCube Neutrino Observatory. The DeepCore infill array in the center of IceCube enables the detection and reconstruction of neutrinos produced by the interaction of cosmic rays in Earth's atmosphere at energies as low as ∼5 GeV. That energy threshold permits measurements of muon neutrino disappearance, over a range of baselines up to the diameter of the Earth, probing the same range of L/Eν as long-baseline experiments but with substantially higher-energy neutrinos. This analysis uses neutrinos from the full sky with reconstructed energies from 5.6 to 56 GeV. We measure Δm322=2.31…
Monitoring and data quality assessment of the ATLAS liquid argon calorimeter
2014
The liquid argon calorimeter is a key component of the ATLAS detector installed at the CERN Large Hadron Collider. The primary purpose of this calorimeter is the measurement of electron and photon kinematic properties. It also provides a crucial input for measuring jets and missing transverse momentum. An advanced data monitoring procedure was designed to quickly identify issues that would affect detector performance and ensure that only the best quality data are used for physics analysis. This article presents the validation procedure developed during the 2011 and 2012 LHC data-taking periods, in which more than 98% of the proton-proton luminosity recorded by ATLAS at a centre-of-mass ener…
Measurement of the Fluctuations in the Number of Muons in Extensive Air Showers with the Pierre Auger Observatory
2021
The successful installation, commissioning, and operation of the Pierre Auger Observatory would not have been possible without the strong commitment and effort from the technical and administrative staff in Malargue. We are very grateful to the following agencies and organizations for financial support: Argentina-Comision Nacional de Energia Atomica, Agencia Nacional de Promocion Cientifica y Tecnologica (ANPCyT), Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Gobierno de la Provincia de Mendoza, Municipalidad de Malargue, NDM Holdings and Valle Las Lenas; in gratitude for their continuing cooperation over land access; Australia-the Australian Research Council; Brazil…
Experimental study of 1/2(+) isomers in At-199,At-201
2014
Using fusion-evaporation reactions, a gas-filled recoil separator, and recoil-electron and recoil-electron-alpha tagging techniques, a new isomeric 1/2(+) state [T-1/2 = 45(3) ms] in At-201 is identified, and an earlier reported corresponding state [T-1/2 = 273(9) ms] in At-199 is confirmed. The 1/2(+) state is suggested to originate from an intruder pi(s(1/2))(-1) configuration. In addition, nuclear structure of states below and above this 1/2(+) state are studied in both nuclei. The isomer decays through a cascade of an E3 transition followed by a mixed M1/E2 transition to the 9/2(-) ground state, and it is interpreted to be fed from nearly spherical 3/2(+) and 5/2(+) states originating f…
Exploration of jet substructure using iterative declustering in pp and Pb–Pb collisions at LHC energies
2020
The ALICE collaboration at the CERN LHC reports novel measurements of jet substructure in pp collisions at $\sqrt{s}$= 7 TeV and central Pb-Pb collisions at $\sqrt{s_{\rm{NN}}}$ = 2.76 TeV. Jet substructure of track-based jets is explored via iterative declustering and grooming techniques. We present the measurement of the momentum sharing of two-prong substructure exposed via grooming, the $z_{\rm{g}}$, and its dependence on the opening angle, in both pp and Pb-Pb collisions. We also present the first measurement of the distribution of the number of branches obtained in the iterative declustering of the jet, which is interpreted as the number of its hard splittings. In Pb-Pb collisions, we…