Search results for "Diffuse reflection"
showing 7 items of 47 documents
A tris-oxovanadium pyrogallate complex: synthesis, structure, and magnetic and electronic properties
2021
International audience; With the aim of identifying new cation-phenolate complexes, we herein investigated the reactivity of pyrogallol (H(3)pgal) with vanadium salts. A trimetallic anionic complex was identified, and found to be formed under a broad set of reaction conditions. This complex, with the formula V3O3(pgal)(3)(3-), consists of three oxovanadium(iv) units connected together by three pyrogallate ligands to afford a bowl-shaped species presenting a pseudo 3-fold symmetry axis. Its crystal structure is reported, as well as its characterisation by a broad set of techniques, including powder X-ray diffraction, thermogravimetric analysis, infrared and Raman spectroscopy, and solid stat…
Non-porous polybutadiene-coated silicas as stationary phases in reversed-phase chromatography
1990
Abstract Non-porous silica of mean particle diameter 1.7 μm (Monospher) was coated with polybutadiene (PBD) following a published procedure. The silicas were prepared with graduated polymer loads up to 8% (w/w). Examination of the PBD-coated packings by means of electron spectroscopy for chemical analysis, scanning electron microscopy, diffuse reflection infrared fourier transform spectroscopy and differential thermal gravimetry indicated that the optimum polymer load was between 1 and 3% (w/w) with regard to a dense coverage corresponding to an average layer thickness of about 4 nm. No silanophilic interactions could be monitored using 1–3% (w/w) coated silicas under reversed-phase conditi…
ESR study of thianthrenium radical cation within acid zeolites
1997
Abstract Thianthrene (E ox = 1.47 V vs NHE) has been adsorbed into a series of zeolites beta (s) and ZSM-5 in the NH 4 + or H + forms, having different particle size and Si/Al ratio. The resulting population of generated thianthrenium radical cation was determined by a combination of diffuse reflectance and ESR spectroscopies. From the results obtained it can be concluded: i) the process takes predominantly place in the interior of the voids (XPS measurements and lack of influence of the particle size); ii) ZSM-5 is more efficient than zeolite s; iii) no strong acid sites are required (both NH 4 + and H + forms produced very similar spin concentrations); iv) the zeolite framework acts isola…
<title>Compact multi-functional skin spectrometry set-up</title>
2006
A portable fibre-optic spectrometry set-up has been assembled and tested for applications in skin diffuse reflectance spectrometry, laser fluorescence spectrometry and multi-wavelength reflection photoplethysmography (multi-PPG) studies. The spectrometry set was tested by diffuse reflectance and fluorescence measurements for diagnostics of skin vascular malformations and pigmented diseases such as nevi and melanoma . In addition, studies of microcirculation in blood vessels located at different depths from the skin surface were performed by the multi-PPG method. The results of skin diffuse reflectance and autofluorescence showed differences in spectra of healthy and pathologic skin. The par…
Comparison of a near-infrared reflectance spectroscopy system and skin conductance measurements for in vivo estimation of skin hydration: a clinical …
2017
Diffuse reflectance spectroscopy system was developed for estimation of skin hydration in the near-infrared spectral range of 900-1700 nm. Experimental setup consisted of a near-infrared spectrometer, Y-type fiber optics probe with 1 detection and 6 illumination fibers, halogen-tungsten light source and a PC. By analyzing diffuse reflectance spectrum, a parameter representing skin hydration by performing baseline correction and calculating the area under the 1450 nm water absorption maximum is proposed. A clinical study was performed acquiring data of skin hydration of 39 patients' forearm skin. Results of the developed system are compared to results obtained by a commercial device based on…
Determination of chromophore distribution in skin by spectral imaging
2012
Possibilities to determine chromophore distribution in skin by spectral imaging were explored. Simple RGB sensor devices were used for image acquisition. Totally 200 images of 40 different bruises of 20 people were obtained in order to map chromophores bilirubin and haemoglobin. Possibilities to detect water in vitro and in vivo were estimated by using silicon photodetectors and narrow band LEDs. The results show that it is possible to obtain bilirubin and haemoglobin distribution maps and observe changes of chromophore parameter values over time by using a simple RGB imaging device. Water in vitro was detected by using differences in absorption at 450 nm and 950 nm, and 650 nm and 950 nm.
Influence of PDA Coating on the Structural, Optical and Surface Properties of ZnO Nanostructures
2020
Polydopamine (PDA) is a new biocompatible material, which has prospects in biomedical and sensor applications. Due to functional groups, it can host wide range of biomolecules. ZnO nanostructures are well known templates for optical sensors and biosensors. The combination of ZnO and PDA results in a change of optical properties of ZnO&ndash