Search results for "Diode"
showing 10 items of 469 documents
Soret emission from water-soluble porphyrin thin films: effect on the electroluminescence response
2009
The emission properties of TSPP [tetrakis(4-sulfonatophenyl) porphyrin] and TMPyP [tetrakis(4-methylpyridyl) porphyrin] in thin films, prepared both by the Langmuir–Blodgett technique and the spin-coating method, have been investigated. Surprisingly, in most of the samples analyzed, the emission spectra do not show the usual two bands typical of porphyrins (in the region 650–750 nm), and depend strongly on the excitation energy. The origin of a new emission band detected at ∼480–500 nm is discussed in terms of the nature of the porphyrin aggregates. Moreover, we demonstrate that the presence or absence of this band in the fluorescence spectrum is directly related to the generation of electr…
Sb-implanted ZnO ultra-thin films
2017
Mild heating of the Zn(C5F6HO2)(2)center dot 2H(2)O center dot CH3(OCH2CH2)(2)OCH3 precursor allowed MOCVD deposition of ZnO films, in a low-pressure horizontal hot-wall reactor, on ITO substrates. The ZnO films were subsequently implanted with Sb ions. XRD measurements provided evidence that they consist of hexagonal, (002) and (101) oriented, crystals. UV-vis spectra showed that the transmittance of these films in the visible region is about 90%. The Sb implanted ZnO film showed a current-voltage characteristic that resembles that of a rectifying diode. This study represents the first example of Sb-implantation in ZnO films obtained by MOCVD.
The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory
2021
FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operati…
SphinX soft X-ray spectrophotometer: Science objectives, design and performance
2011
The goals and construction details of a new design Polish-led X-ray spectrophotometer are described. The instrument is aimed to observe emission from entire solar corona and is placed as a separate block within the Russian TESIS X- and EUV complex aboard the CORONAS-PHOTON solar orbiting observatory. SphinX uses silicon PIN diode detectors for high time resolution measurements of the solar spectra in the range 0.8–15 keV. Its spectral resolution allows for discerning more than hundred separate energy bands in this range. The instrument dynamic range extends two orders of magnitude below and above these representative for GOES. The relative and absolute accuracy of spectral measurements is e…
Argon broadening of the 13CO R(0) and R(7) transitions in the fundamental band at temperatures between 80 and 297K: comparison between experiment and…
2003
We present measurements of Ar-broadening parameters for the R(0) and R(7) lines in the fundamental band of13CO at eight temperatures from 80 to 297 K. The broadening parameters are determined by simultaneous least-squares fitting of spectra recorded using a frequency stabilized diode laser spectrometer. The comparison of the broadening parameter values for R(7) derived at room temperature and different pressures from different line profiles shows that an empirical line profile, which takes into account narrowing effects (Dicke narrowing and absorber speed dependence) but neglects any correlation between collisions, is able to describe the observed lines with constant values of the narrowing…
Eye tracking analysis of minor details in films for audio description
2012
This article focuses on the many instances when minute details found in feature films may have direct implications upon the development of both the visual and plot narratives. The main question we would like to ask examines whether very subtle details which may easily go unnoticed by the viewer should be audio described. To assess the visual consciousness of such minute details, a perception experiment was conducted using eye-tracking technology and questionnaires. Though the result is not conclusive, it shows a clear methodological approach in the field of the audio description of visual details, and does give some indication as to what should be taken into consideration in future studies …
Multi-sensory approaches to (audio) describing the visual arts
2012
Making art accessible to blind patrons requires the ability to convey explicit and implicit visual messages through non-visual forms. Audio description is often seen as the best way to offer visual texts to blind people; however, one may query whether words alone are sufficient to convey the subtleties of art and to transport the emotional charge such works offer. It is a fact that the dialogue between words and touch may allow these particular “readers” to “see” art in its tangible forms, but perhaps more is needed if one is to give them the opportunity to live the art experience to the full. This article discusses different multi-sensory approaches to making art available to visually impa…
Lyrics against images: music and audio description
2012
Music has been an integral part of films from as far back as the silent movie era, where a piano accompaniment was used to build the narrative and an orchestra was used to drown out the sound of the projector. Music in films can encompass a wide array of elements, from a song to a whistle, and can play many roles, as has been commented upon by many researchers. Due to the relevance of music in film narrative, it is an element which merits attention when it comes to making a film accessible, be it through Audio description, Audio subtitling, Sign Language or Subtitling for the Deaf and Hard-of-Hearing. This article focuses on Audio description (AD) and how music is handled in audio described…
Air stable hybrid organic-inorganic light emitting diodes using ZnO as the cathode
2007
An air stable hybrid organic-inorganic light emitting device is presented. This architecture makes use of metal oxides as charge injecting materials into the light emitting polymer, avoiding the use of air sensitive cathodes commonly employed in organic light emitting diode manufacturing. We report the application of zinc oxide as a cathode in an organic light emitting device. This electroluminescent device shows high brightness levels reaching 6500 cd/m2 at voltages as low as 8 V. Compared to a conventional device using low workfunction metal cathodes, our device shows a lower turn-on voltage and it can operate in air.
Photoluminescence quantum yield exceeding 80% in low dimensional perovskite thin-films via passivation control
2017
Quasi-2D perovskites with the BA : MA molar ratio equal to 3 : 3 show a remarkable PLQY exceeding 80%, thanks to the use of an electron donor as the passivating agent. These films have been applied in LEDs that exhibit high brightness exceeding 1000 cd m−2 and current efficiencies >3 cd A−1.