Search results for "Earing"
showing 10 items of 867 documents
Effect of self-etching primer/adhesive and conventional bonding on the shear bond strength in metallic and ceramic brackets
2011
Introduction: Bracket debonding from the tooth surface is a common problem in fixed orthodontics. The aims of the present study were to assess the bond strength and failure sites in two ways of bonding technique, with metallic and ceramic brackets. Material and Methods: One hundred premolars were assigned to 4 groups of 25 each: Group A, metallic brackets/ conventional procedure; Group B, metallic brackets/Transbond XT; Group C, ceramic brackets/conventional procedure; and Group D, ceramic brackets/Transbond XT. Transbond XT composite paste was used for bracket bonding and cured by conventional light-cure device. Specimens were subjected to thermocycling. One week after bonding shearing for…
Exercise loading history and femoral neck strength in a sideways fall: A three-dimensional finite element modeling study
2016
Over 90% of hip fractures are caused by falls. Due to a fall-induced impact on the greater trochanter, the posterior part of the thin superolateral cortex of the femoral neck is known to experience the highest stress, making it a fracture-prone region. Cortical geometry of the proximal femur, in turn, reflects a mechanically appropriate form with respect to habitual exercise loading. In this finite element (FE) modeling study, we investigated whether specific exercise loading history is associated with femoral neck structural strength and estimated fall-induced stresses along the femoral neck. One hundred and eleven three-dimensional (3D) proximal femur FE models for a sideways falling situ…
Otosclerosis associated with type B-1 inner ear malformation
2010
Malformations of bony inner ear are rare anomalies occurring in approximately 20% of patients with congenital sensorineural hearing loss. Conductive hearing loss is usually associated with abnormalities of the external and middle ear. Recent reports of patients with lateral semicircular canal malformations indicate inner ear malformations to be associated with sensorineural or conductive hearing loss. Differential diagnosis of conductive hearing loss should include otosclerosis, isolated ossicular deformities, inner ear anomalies or a combination of these. In this report, a case is described with right vestibule-lateral semicircular canal dysplasia presenting at our centre with bilateral ot…
Intratumoral Haemorrhage Causing an Unusual Clinical Presentation of a Vestibular Schwannoma
2012
We present a case of an elderly woman with no history of audiological disease with sudden onset of visual and hearing deficits associated with systemic clinical signs. On examination she had impairment of right CNs from V to X. CT and MR imaging demonstrated a cystic vestibular schwannoma with a rare intralesional fluid-fluid level correlated to a recent bleed. We include high quality MR images to show the acute impairment of the cranial nerves next to the tumour after acute bleeding. Our case report includes a voxel-based morphometry (VMB) analysis of the tumour that, as far as we know, has never been done before for such a tumour. VBM analysis was performed to calculate the hypothesized …
The impact of isolated lesions on white-matter fiber tracts in multiple sclerosis patients
2015
Infratentorial lesions have been assigned an equivalent weighting to supratentorial plaques in the new McDonald criteria for diagnosing multiple sclerosis. Moreover, their presence has been shown to have prognostic value for disability. However, their spatial distribution and impact on network damage is not well understood. As a preliminary step in this study, we mapped the overall infratentorial lesion pattern in relapsing–remitting multiple sclerosis patients (N = 317) using MRI, finding the pons (lesion density, 14.25/cm3) and peduncles (13.38/cm3) to be predilection sites for infratentorial lesions. Based on these results, 118 fiber bundles from 15 healthy controls and a subgroup of 23 …
Presentation and Outcomes of Pregnancy in Patients With Autoimmune Hepatitis
2018
Autoimmune hepatitis (AIH) frequently affects women of childbearing age in whom the desire to have a family raises the question regarding the potential risks for the fetus and the mother. The information on AIH in pregnant patients is scarce.1 The aims of this study were (1) to identify the risk factors associated with flares in pregnant patients diagnosed with AIH, (2) to determine the course of AIH in patients with pregnancy-related flares, and (3) to describe the outcome of AIH diagnosed in the postpartum period.
Distribution and phenotype ofGJB2mutations in 102 Sicilian patients with congenital non syndromic sensorineural hearing loss
2014
Objective: To evaluate the frequency of GJB2 mutations and their correlation with phenotype in Sicilian non-syndromic sensorineural hearing loss (NSHL) patients. Design: Sequencing of the coding region, basal promoter, exon 1, and donor splice site of the GJB2 gene; screening for the presence of the two common GJB6 deletions. Study sample: A cohort of 102 Sicilian NSHL patients. Results: Fifteen different mutations in GJB2 and seventeen different genotypes were detected. No GJB6 mutations were found. The hearing impairment was profound in the 64.72% of probands (mean PTA 0.25 – 4 kHz of 88.82 26.52 dB HL). A total of 81.37% of patients harboured at least one c.35delG allele; c.167delT and c…
Identification of D179H, a novel missense GJB2 mutation in a Western Sicily family
2013
The main purpose of this study was to describe a novel missense mutation (p.D179H) found in a Western Sicily family and to examine the genetic and audiologic profiles of all family members by performing a GJB2 and GJB6 mutations analysis and a complete audiologic assessment. The proband was a 3-month-old infant with a congenital profound sensorineural hearing loss; direct sequencing of the GJB2 revealed the presence of a c.35delG mutation in the heterozygous state and a heterozygous G[C transition at nucleotide 535 in trans; this novel mutation, called p.D179H, resulted in an aspartic acid to histidine change at codon 179. It was also evidenced in the heterozygous state in two members of th…
Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipient…
2010
Abstract: The Nucleus CI24RE Freedom device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 μV. However, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C …
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…