Search results for "Electronic"

showing 10 items of 17076 documents

Noninvasive optical diagnostics of enhanced green fluorescent protein expression in skeletal muscle for comparison of electroporation and sonoporatio…

2015

We highlight the options available for noninvasive optical diagnostics of reporter gene expression in mouse tibialis cranialis muscle. An in vivo multispectral imaging technique combined with fluorescence spectroscopy point measurements has been used for the transcutaneous detection of enhanced green fluorescent protein (EGFP) expression, providing information on location and duration of EGFP expression and allowing quantification of EGFP expression levels. For EGFP coding plasmid (pEGFP-Nuc Vector, 10  μg/50  ml 10  μg/50  ml ) transfection, we used electroporation or ultrasound enhanced microbubble cavitation [sonoporation (SP)]. The transcutaneous EGFP fluorescence in live mice was monit…

0301 basic medicineMaleGreen Fluorescent ProteinsBiomedical EngineeringNanotechnologyTransfectionFluorescence spectroscopyGreen fluorescent proteinBiomaterials03 medical and health sciencesMiceSonicationAnimalsMuscle SkeletalReporter geneChemistryHistocytochemistryElectroporationfungiOptical ImagingTransfectionEquipment DesignFluorescenceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsMice Inbred C57BL030104 developmental biologyElectroporationBiophysicsFemaleSonoporationPreclinical imagingJournal of biomedical optics
researchProduct

Cardiac electrical defects in progeroid mice and Hutchinson-Gilford progeria syndrome patients with nuclear lamina alterations

2016

This work was supported by Spanish Ministry of Economy and Competitiveness (MINECO) Grants SAF2010-16044 and SAF2013-46663-R (to V.A.), SAF2011-30312 and SAF2014-58286-C2-1-R (to L.H.-M.), SAF2011-30088 (to E.D.), and SAF2014-52413-R (to C.L.-O.) and Fondo de Investigación Sanitaria del Instituto de Salud Carlos III Grants RD12/0042/0028 (to V.A.), RD12/0042/0011 (to J.T.), and RD12/0042/0002 (to L.H.-M.), with cofunding from the Fondo Europeo de Desarrollo Regional and the Progeria Research Foundation. J.A.G. is the recipient of a U-Mobility Grant from the Marie Curie cofunding of Regional, National and International Programme (Grant 246550). The Instituto Universitario de Oncología is sup…

0301 basic medicineMaleHutchinson–Gilford progeria syndrome calcium handling connexin43 prelamin A progerinElectrònica en cardiologia030204 cardiovascular system & hematologyPathogenesisCiencias Biomedicas0302 clinical medicineProgeriaCardiac Conduction System DiseasefisiologiapatologíaTecnología médicaChildCiencias médicasMice KnockoutProgeriaprelamin AMultidisciplinaryintegumentary systemMetalloendopeptidasesHeartProgerinHutchinson-Gilford progeria syndrome3. Good health:Enginyeria biomèdica::Electrònica biomèdica::Electrònica en cardiologia [Àrees temàtiques de la UPC]Sarcoplasmic Reticulummedicine.anatomical_structurePNAS PlusChild Preschoolcardiovascular systemNuclear laminaFemalemedicine.symptomBradycardiaAdultmedicine.medical_specialtycongenital hereditary and neonatal diseases and abnormalitiesAdolescentBiology03 medical and health sciencesQRS complexYoung AdultElectrònica mèdicaInternal medicinemedicineAnimalsHumansPR intervalHutchinson–Gilford progeria syndromeNuclear LaminaMyocardiumMembrane Proteinsnutritional and metabolic diseasesArrhythmias Cardiacmedicine.diseaseMedical electronicsconnexin43Mice Inbred C57BL030104 developmental biologyEndocrinologyVentricleprogerinConnexin 43calcium handlingsistema cardiovascularCalcium
researchProduct

Improved electroless platinum contacts on CdZnTe X- and γ-rays detectors

2020

AbstractPlatinum is a promising candidate for the realization of blocking electrical contacts on cadmium-zinc-telluride (CdZnTe or CZT) radiation detectors. However, the poor mechanical adhesion of this metal often shortens the lifetime of the final device. In this work, a simple and effective procedure to obtain robust platinum contacts by electroless deposition is presented. Microscopical analysis revealed the final thickness and composition of the contact layer and its adhesion to the bulk crystal. The blocking nature of the Pt-CdZnTe junction, essential to obtain low noise devices, was confirmed by current–voltage measurements. The planar Pt-CdZnTe-Pt detectors showed good room temperat…

0301 basic medicineMaterials for devicesMaterials sciencechemistry.chemical_elementlcsh:MedicineElectronCZT detectorELECTRIC-FIELD PROFILE;TRANSIENT-CURRENT;TRANSPORT-PROPERTIESPULSE-SHAPE;CDTE;PERFORMANCE;RESISTIVITY;DEPOSITION;BULKParticle detectorArticle03 medical and health sciences0302 clinical medicinePlanarlcsh:ScienceMultidisciplinarybusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorlcsh:RCarrier lifetimeX-ray and gamma ray detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electrical contactsMaterials scienceFull width at half maximum030104 developmental biologychemistrysemiconductor detectorOptoelectronicslcsh:QbusinessPlatinum030217 neurology & neurosurgeryScientific Reports
researchProduct

Phase stability and electronic structure of iridium metal at the megabar range

2019

[EN] The 5d transition metals have attracted specific interest for high-pressure studies due to their extraordinary stability and intriguing electronic properties. In particular, iridium metal has been proposed to exhibit a recently discovered pressure-induced electronic transition, the so-called core-level crossing transition at the lowest pressure among all the 5d transition metals. Here, we report an experimental structural characterization of iridium by x-ray probes sensitive to both long- and short-range order in matter. Synchrotron-based powder x-ray diffraction results highlight a large stability range (up to 1.4 Mbar) of the low-pressure phase. The compressibility behaviour was char…

0301 basic medicineMaterials scienceAbsorption spectroscopySciencechemistry.chemical_elementElectronic structureMolecular electronic transitionArticle03 medical and health sciencessymbols.namesake0302 clinical medicineTransition metalIridiumSpectroscopyCondensed-matter physicsSpectroscopyExafsBulk modulusMultidisciplinaryFermi levelQRCondensed Matter Physics030104 developmental biologychemistryChemical physicsFISICA APLICADAsymbolsMedicineDen kondenserade materiens fysik030217 neurology & neurosurgeryPressures
researchProduct

Collagen-inducing biologization of prosthetic material for hernia repair: Polypropylene meshes coated with polyP/collagen

2017

Prostethic mesh material such as nonabsorbable polypropylene used in open and laparoscopic hernia repair are characterized by controllable mechanical properties but may elicit undesirable physiological reactions due to the nonphysiological inert polymer material. We succeeded in developing a biocompatible coating for these meshes, based on a physiological inorganic polymer, polyphosphate (polyP) that is morphogenetically active and used as a metabolic energy source, and a collagen matrix. The polyP/collagen hydrogel material was prepared by a freeze-extraction method, with amorphous Ca-polyP microparticles. Electron microscopy (SEM and REM) studies revealed that the polyP/collagen coats are…

0301 basic medicineMaterials scienceBiomedical Engineering02 engineering and technologyMatrix (biology)engineering.materiallaw.inventionBiomaterials03 medical and health scienceschemistry.chemical_compoundCoatinglawchemistry.chemical_classificationPolypropyleneInorganic polymerMesenchymal stem cellPolymerAnatomy021001 nanoscience & nanotechnology030104 developmental biologychemistryengineeringElectron microscope0210 nano-technologyLayer (electronics)Biomedical engineeringJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

FRET-based method for evaluation of the efficiency of reversible and irreversible sonoporation.

2017

It is widely known that not all of the treated cells survive after introduction of exogenous molecules via any physical method. Therefore, it is important to develop methods that would allow simultaneous evaluation of both molecular delivery efficiency and cell viability. This study presents Forster resonance energy transfer (FRET)-based method that allows molecular transfer and cell viability evaluation in a single measurement by employing two common fluorescent dyes, namely, ethidium bromide and trypan blue. The method has been validated using cell sonoporation. The FRET-based method allows the efficiency evaluation of both reversible and irreversible sonoporation in a single experiment. …

0301 basic medicineMaterials scienceCell SurvivalSonicationSingle measurementBiomedical EngineeringCHO CellsBiomaterials03 medical and health scienceschemistry.chemical_compoundSonicationCricetulusEthidiumFluorescence Resonance Energy TransferAnimalsHumansViability assayFluorescent DyesTrypan BlueFluorescenceAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials030104 developmental biologyFörster resonance energy transferchemistryBiophysicsTrypan blueEthidium bromideSonoporationJournal of biomedical optics
researchProduct

Advanced Techniques of Micro-Analysis and Confocal Microscopy: Perspectives for Studying Chemical and Structural Changes at the Interface Between Res…

1995

Migration of trace amounts of elements and structural changes characterize the interface between immiscible substances. The contact zone among filling materials, saliva, and the cavity wall has the additional function of preventing the progress of leakage and subsequent caries. Difficulties in chemically and structurally analyzing the gradients of composition in an interface of microscopic dimensions characterize the experimental situation. The use of advanced techniques of instrumental micro-analysis and techniques of micro-visualization is our approach to the problem. With confocal laser scanning microscopy (CLSM), effects of the components of the filling material on the structure of the…

0301 basic medicineMaterials scienceEnamel paintAnalytical chemistry030206 dentistryGeneral MedicineLaserElectron spectroscopylaw.invention03 medical and health sciences030104 developmental biology0302 clinical medicineX-ray photoelectron spectroscopylawConfocal microscopyvisual_artvisual_art.visual_art_mediumAdhesiveComposite materialCavity wallLeakage (electronics)Advances in Dental Research
researchProduct

Mapping brain activity with flexible graphene micro-transistors

2016

arXiv:1611.05693v1.-- et al.

0301 basic medicineMaterials scienceFOS: Physical sciences02 engineering and technologylaw.invention03 medical and health scienceslawGeneral Materials ScienceElectronicsPhysics - Biological PhysicsNeural implantsBioelectronicsBioelectronicsbusiness.industryGrapheneSensorsMechanical EngineeringTransistorGeneral Chemistry021001 nanoscience & nanotechnologyCondensed Matter PhysicsField-effect transistorsMicroelectrodeBrain implant030104 developmental biologyBiological Physics (physics.bio-ph)Mechanics of MaterialsFOS: Biological sciencesQuantitative Biology - Neurons and CognitionOptoelectronicsNeurons and Cognition (q-bio.NC)Charge carrierField-effect transistorGraphene0210 nano-technologybusiness2D Materials
researchProduct

Out-of-plane orientation of luminescent excitons in two-dimensional indium selenide.

2019

Van der Waals materials offer a wide range of atomic layers with unique properties that can be easily combined to engineer novel electronic and photonic devices. A missing ingredient of the van der Waals platform is a two-dimensional crystal with naturally occurring out-of-plane luminescent dipole orientation. Here we measure the far-field photoluminescence intensity distribution of bulk InSe and two-dimensional InSe, WSe2 and MoSe2. We demonstrate, with the support of ab-initio calculations, that layered InSe flakes sustain luminescent excitons with an intrinsic out-of-plane orientation, in contrast with the in-plane orientation of dipoles we find in two-dimensional WSe2 and MoSe2 at room-…

0301 basic medicineMaterials sciencePhotoluminescenceElectronic properties and materialsExcitonScienceGeneral Physics and Astronomychemistry.chemical_elementPhysics::Optics02 engineering and technologyTwo-dimensional materials7. Clean energyGeneral Biochemistry Genetics and Molecular BiologyArticleCrystal03 medical and health sciencessymbols.namesakeCondensed Matter::Materials SciencePhysics::Atomic and Molecular ClustersPhysics::Atomic Physicslcsh:ScienceMultidisciplinarybusiness.industryCondensed Matter::OtherQGeneral Chemistry021001 nanoscience & nanotechnologyCondensed Matter::Mesoscopic Systems and Quantum Hall EffectDipole030104 developmental biologySemiconductorchemistrysymbolsOptoelectronicslcsh:Qvan der Waals forcePhotonics0210 nano-technologybusinessIndiumNature communications
researchProduct

Matching the Directions of Electric Fields from Triboelectric and Ferroelectric Charges in Nanogenerator Devices for Boosted Performance

2020

Summary Embedding additional ferroelectric dipoles in contacting polymer layers is known to enhance the performance of triboelectricnanogenerator (TENG) devices. However, the influence of dipoles formed between the triboelectric surface charges on two contacting ferroelectric films has been ignored in all relevant studies. We demonstrate that proper attention to the alignment of the distinct dipoles present between two contacting surfaces and in composite polymer/BaTiO3 ferroelectric films can lead to up to four times higher energy and power density output compared with cases when dipole arrangement is mismatched. For example, TENG device based on PVAc/BaTiO3 shows energy density increase f…

0301 basic medicineMaterials sciencePolymers02 engineering and technologyArticle03 medical and health sciencesElectric field:NATURAL SCIENCES:Physics [Research Subject Categories]DevicesNanotechnologySurface chargelcsh:ScienceTriboelectric effectPower densityMultidisciplinarybusiness.industryNanogeneratorElectrostatic induction021001 nanoscience & nanotechnologyFerroelectricityDipole030104 developmental biologyElectromagnetic Field13. Climate actionOptoelectronicsNanoparticleslcsh:Q0210 nano-technologybusinessiScience
researchProduct