Search results for "Electrooculography"
showing 10 items of 43 documents
Electrophysiological findings of neuronal ceroid lipofuscinosis in heterozygotes.
1988
Nineteen obligate heterozygotes, 8 individuals at risk of being heterozygote, and 10 patients afflicted with four different forms of neuronal ceroid lipofuscinosis were examined electrophysiologically. The group of obligate heterozygotes was compared to age-matched control groups. Statistically significant differences were found between scotopic b-wave amplitudes, P-ERG amplitudes, and EOG light peaks of the obligate carriers of the juvenile type and the control subjects. The photopic L-ERGs and the latencies of the VEPs were mostly within the normal range. The findings represent the first evidence of functional ophthalmological changes in obligate carriers of neuronal ceroid lipofuscinosis…
Mismatch negativity during objective and subjective sleepiness.
1997
The mismatch negativity (MMN) and P3 of auditory event-related potentials were studied during subjectively and objectively (physiologically) defined sleepiness under optimal stimulus conditions for MMN elicitation. The MMN and P3 were elicited by either small or large unattended auditory deviants presented to the left ear. The participant's task was to detect either rare auditory targets presented to the right ear or rare changes in the light flashes. Eleven young adults served as participants in a nighttime experiment. The MMN declined especially at Fz and Cz but not so markedly at the right mastoid as either subjective or objective alertness decreased. The amplitude of P3 also decreased d…
Electrophysiological evidence for an inverse benzodiazepine receptor agonist in panic disorder.
1999
Abstract Inverse agonists of the GABA A receptor clearly decrease the amplitudes of the spontaneous EEG in the P-frequency range. Therefore, we tested the hypothesis that panic patients exhibit a reduction of the EEGs spectral power in the P-frequency band. Ten unmedicated patients with panic disorder and agoraphobia according to DSM-III-R criteria and 10 matched controls were investigated under baseline conditions, after hyperventilation and 30 min after hyperventilation. EEG recordings from the position P z and C z were performed under eyes closed conditions. At baseline conditions the patients suffering from panic disorder depicted a reduced P-power reaching statistically significance fo…
Incidence and anatomy of gaze-evoked nystagmus in patients with cerebellar lesions.
2011
Background: Disorders of gaze-holding—organized by a neural network located in the brainstem or the cerebellum—may lead to nystagmus. Based on previous animal studies it was concluded that one key player of the cerebellar part of this gaze-holding neural network is the flocculus. Up to now, in humans there are no systematic studies in patients with cerebellar lesions examining one of the most common forms of nystagmus: gaze-evoked nystagmus (GEN). The aim of our present study was to clarify which cerebellar structures are involved in the generation of GEN. Methods: Twenty-one patients with acute unilateral cerebellar stroke were analyzed by means of modern MRI-based voxel-wise lesion-behavi…
Variance Thresholded EMD-CCA Technique for Fast Eye Blink Artifacts Removal in EEG
2017
International audience; Eye blink (EB) artifacts generated during eye blinks often contaminate electroencephalogram (EEG) signal. Previously Empirical Mode Decomposition (EMD) and Canonical Correlation Analysis (CCA), hybrid EMD-CCA were developed for EB artifact removal in EEG. However, EMD restricts the hybrid algorithm for real time implementation due to its slow processing nature, hence the algorithm has to be enhanced so that it can be a viable solution for real-time EB artifact removal. In this research work, to avoid applying EMD repetitively as and when EB artifacts occur, a method to use EMD minimally is approached. A suitable EB artifact region is detected through a variance thres…
European vestibular experiments on the Spacelab-1 mission: 2. Experimental equipment and methods
1986
A series of vestibular experiments were performed in conjunction with the first Spacelab mission, consisting of sets of pre-, in- and postflight tests. A multipurpose experimental apparatus used for the diverse flight and ground tests is presented. Additional apparatus together with the multi-purpose package were used in the baseline data collection facility at the landing site at NASA Dryden Flight Research Facility for the ground tests. The tests involved optokinetic, caloric and mechanical (whole-body or head-alone) stimulation. The latter included linear acceleration in the subject's x, y and z axes, static roll and yaw about an earth-vertical axis. Physiological parameters such as elec…
An Electrooculography based Human Machine Interface for wheelchair control
2019
International audience; This paper presents a novel single channel Electrooculography (EOG) based efficient Human–Machine Interface (HMI) for helping the individuals suffering from severe paralysis or motor degenerative diseases to regain mobility. In this study, we propose a robust system that generates control command using only one type of asynchronous eye activity (voluntary eye blink) to navigate the wheelchair without a need of graphical user interface. This work demonstrates a simple but robust and effective multi-level threshold strategy to generate control commands from multiple features associated with the single, double and triple voluntary eye blinks to control predefined action…
Objective Extraction of Evoked Event-Related Oscillation from Time-Frequency Representation of Event-Related Potentials
2020
Evoked event-related oscillations (EROs) have been widely used to explore the mechanisms of brain activities for both normal people and neuropsychiatric disease patients. In most previous studies, the calculation of the regions of evoked EROs of interest is commonly based on a predefined time window and a frequency range given by the experimenter, which tends to be subjective. Additionally, evoked EROs sometimes cannot be fully extracted using the conventional time-frequency analysis (TFA) because they may be overlapped with each other or with artifacts in time, frequency, and space domains. To further investigate the related neuronal processes, a novel approach was proposed including three…
Internuclear ophthalmoplegia of abduction: clinical and electrophysiological data on the existence of an abduction paresis of prenuclear origin.
1992
Three patients showed unilateral and five bilateral abduction paresis. Five had associated adduction nystagmus of the contralateral eye. Electrophysiological testing of masseter and blink reflexes indicated an ipsilateral rostral pontine or mesencephalic lesion, and excluded a lesion of the infranuclear portion of the abducens nerve. Abduction paresis was attributed to impaired inhibition of the tonic resting activity of the antagonistic medial rectus muscle. The prenuclear origin of the disorder is based on morphological and neurophysiological evidence of an ipsilateral inhibitory connection between the paramedian pontine reticular formation and the oculomotor nucleus running close to but …
REM sleep behavior disorder in a patient with frontotemporal dementia
2010
We describe a patient with frontotemporal dementia (FTD), a tauopathy, who also showed clinical and polysomnographic features of REM sleep behavior disorder (RBD). The patient is a 78-year-old male with a 1 year history of behavioral dysfunction involving emotion, character and social functioning. Brain imaging and the results of neuropsychological testing were consistent with a diagnosis of FTD. Sleep symptom onset occurred some years before the behavioral changes, and consisted of unpleasant dreams, vocalization, and prominent motor behaviors. A polysomnography confirmed the diagnosis of RBD. Our findings support the hypothesis that RBD, although more frequent in synucleinopathies, might …