Short implants (8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: A meta-analysis of RCT`s in h…
2019
Background One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high survival rate of implants placed next to sinus elevation, this technique presents complications that can be avoided by placing short implants, an option that also presents high survival rates. For this reason, the aim of this study is to compare the survival rate, marginal bone loss and complications associated with short implants (<8 mm) versus longer implants (≥8mm) placed with lateral sinus floor elevation in posterior atrophic maxillae. Material and Methods A literature search was conducted …
In vivo and in vitro degradation of a novel bioactive guided tissue regeneration membrane
2006
The aim of this study was to assess degradation of a novel bioactive guided tissue regeneration (GTR) membrane and to quantify the concurrent tissue responses. Pieces of membrane composed of poly-l-lactide, poly-d,l-lactide, trimethylenecarbonate and polyglycolide were dipped into an N-methyl-2-pyrroline (NMP) solution and implanted in the mandibles of 10 sheep. The animals were sacrificed at 6-104 weeks. Parallel in vitro degradation was analysed by measuring the inherent viscosity, water absorption and remaining mass. One of the 2 in vitro sets of membranes was prehandled with NMP. At 6-26 weeks in vivo, the gradually more degraded implants were surrounded by a fibrous network. At 52 and …
Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic revie…
2018
OBJECTIVES To evaluate the implant failure, marginal bone loss (MBL), and other biological or technical complications of restorations supported by tilted and straight implants after at least 3 years in function. METHODS Electronic and manual searches were performed in MEDLINE, Embase, Web of Science, and OpenGrey to identify clinical studies published up to December 2017. After duplicate study selection and data extraction, the risk of bias was assessed with the ROBINS-I tool. Random-effects meta-analyses of relative risks (RRs) or mean differences (MD) and their 95% confidence intervals (CIs) were performed, followed by subgroup/sensitivity analyses and application of the GRADE approach. R…
Soft tissue integration of different abutment surfaces: An experimental study with histological analysis
2021
OBJECTIVE To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among gro…
Systemic risk factors for peri-implant bone loss: a systematic review and meta-analysis
2014
The aim of this study was to determine the influence of patient-related systemic risk factors (systemic disease, genetic traits, chronic drug or alcohol consumption, and smoking status) on peri-implant bone loss at least 1 year after implant installation and prosthetic loading. An electronic search was performed of MEDLINE, EMBASE, and The Cochrane Central Register of Controlled Trials up to January 2012. One thousand seven hundred and sixty-three studies were identified. After applying a three-stage screening process, 17 articles were included in the qualitative analysis, but only 13 in the quantitative analysis, since smoking was a common exposure. The meta-analysis of these 13 studies (4…
Stability and marginal bone loss in implants placed using piezoelectric osteotomy versus conventional drilling: systematic review and meta-analysis.
2021
Background The main objective of this systematic review was to compare primary and secondary implant stability between placement with piezoelectric osteotomy and conventional drilling, comparing marginal bone losses as a secondary objective. Material and Methods An electronic search was conducted using PubMed (MEDLINE), Scopus, and Cochrane Library (Wiley) databases, besides a manual search. Results A total of 153 articles were retrieved, 39 from Pubmed, 44 from Scopus, and 70 from the Cochrane Library. After removing duplicates, 112 articles (1 from the manual search) were screened, and 9 were finally selected for qualitative and statistical analyses. Conclusions Piezoelectric surgery is a…
Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, osseodensification: an in vitro study
2020
Background Primary stability is an important key determinant of implant osseointegration. We investigated approaches to improve primary implant stability using a new drilling technique termed osseodensification (OD), which was compared with the conventional under-drilling (UD) method utilized for low-density bones. Material and Methods We placed 55 conical internal connection implants in each group, in 30 low-density sections of pig tibia. The implants were placed using twist drill bits in both groups; groups Under Drilling (UD) and Osseodensification (OD) included bone sections subjected to conventional UD and OD drilling, respectively. Before placing the implants, we randomized the bone s…
Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study
2018
GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…
Assessing osseointegration of metallic implants with boronized surface treatment
2020
Background Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. Material and Methods Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined …
Benign paroxysmal positional vertigo as a complication of osteotome expansion of the maxillary alveolar ridge.
2001
Benign paroxysmal positional vertigo (BPPV) is a common vestibular end organ disorder characterized by short, often recurrent episodes of vertigo that are triggered by certain head movements in the plane of the posterior semicircular canals. BPPV may be idiopathic or secondary to a number of underlying conditions such as head injury, viral labyrinthitis, stapes surgery, and chronic suppurative otitis media. 1,2 The most commonly accepted theory postulates the development of BPPV as a result of canalolithiasis, 3 heavy, inorganic particles detached from the otoconial layer by degeneration or head trauma gravitate into the posterior semicircular canal and act as a plunger on the endolymph and…