Search results for "Enhancement."
showing 10 items of 557 documents
High definition colonoscopy combined with i-Scan is superior in the detection of colorectal neoplasias compared with standard video colonoscopy: a pr…
2010
Introduction Colonoscopy is the accepted gold standard for the detection of colorectal cancer. The aim of the current study was to prospectively compare high definition plus (HD+) colonoscopy with I-Scan functionality (electronic staining) vs. standard video colonoscopy. The primary endpoint was the detection of patients having colon cancer or at least one adenoma. Methods A total of 220 patients due to undergo screening colonoscopy, postpolypectomy surveillance or with a positive occult blood test were randomized in a 1 : 1 ratio to undergo HD+ colonoscopy in conjunction with I-Scan surface enhancement (90i series, Pentax, Tokyo, Japan) or standard video colonoscopy (EC-3870FZK, Pentax). D…
Tissue characterization of benign brain tumors: Use of NMR-tissue parameters
1988
Abstract To evaluate the potentials of NMR tissue parameters for tissue characterization we investigated 68 patients with benign brain tumors. Tissue parameters were accurately measured by a recently developed interlaced triple sequence. Each individual tumor was characterized by a set of three numbers (relaxation times T 1 and T 2 and proton density Rho). Different tumors exhibited significant overlaps of the three tissue parameters. Therefore a reliable prediction of the histological diagnosis based on the quantitative analysis of tissue parameters alone was not possible. T 2 -prolongation correlated well with water content and “regressive changes” in meningiomas and neuromas.
High-definition imaging in endoscopic transsphenoidal pituitary surgery.
2011
Background The transsphenoidal approach to sellar lesions has evolved enormously since its first description in the early 20th century. Endoscopic surgical strategies have become an integral part of the surgical armamentarium. More recently, high-definition (HD) digital cameras with better image resolution were introduced, although their value for the surgical procedure remains equivocal. The purpose of this study was to compare the image quality of a standard-definition (SD) camera with a new HD camera. Methods A transsphenoidal pituitary adenomectomy was recorded simultaneously in HD and SD resolution. Eight experienced neurosurgeons were asked to identify predefined as well as not predef…
Evolving endoscopic strategies for detection and treatment of neoplastic lesions in inflammatory bowel disease
2013
The paradigm for neoplasia surveillance in IBD is rapidly evolving with advancements in endoscopic imaging technology. Modern technology has demonstrated a remarkably improved capacity to detect and characterize subtle neoplastic lesions. As such, practices of obtaining interval random biopsy specimens to identify “invisible”neoplasia and of recommending total proctocolectomy for treatment of early neoplastic lesions are gradually being phased out. Further research is required to confirm the safety and effectiveness of endoscopic resection of more advanced neoplastic lesions, including DALMs and lesions bearing HG-IEN. Moving forward, studies evaluating CRC risk profiles in IBD patients wou…
Gene Therapy With a High-Affinity Single-Chain p53-Specific TCR Mediates Potent Anti-Tumor Response Without Inducing Gvhd In Vivo
2013
Abstract The adoptive transfer of tumor-reactive cells is a promising approach in the treatment of human malignancies, but the challenge of isolating T cells with high-avidity for tumor antigens in each patient has limited its widespread application. Using HLA-A2.1 transgenic mice, we have demonstrated the feasibility of T-cell receptor (TCR) gene transfer into T cells to circumvent self-tolerance to the widely expressed human p53(264-272) tumor-associated antigen and developed approaches to generate high-affinity CD8-independent TCR. However, a safety concern of TCR gene transfer is the risk of pairing between introduced and the naturally expressed endogenous TCR chains, resulting in the g…
Spontaneous echo contrast caused by platelet and leukocyte aggregates?
2001
Background and Purpose —Spontaneous echocardiographic contrast (SEC) is correlated to clinical thromboembolic events. We sought to determine the origin of SEC by utilizing direct analysis of left atrial blood. Methods —We examined the blood of 13 patients with and 19 without SEC. Blood samples were taken from the femoral vein and artery and from the right and left atria after transseptal puncture. Samples were incubated with fluorescence-labeled antibodies directed against the platelet (CD41a-PE, CD42b-PE, and CD62p-FITC) and leukocyte membrane epitopes (CD45-APC and CD14-FITC). The expressed epitopes were analyzed by dual laser flow cytometry immediately after blood withdrawal. Results —I…
Successful adenovirus-mediated wild-type p53 gene transfer in patients with bladder cancer by intravesical vector instillation.
2002
PURPOSE: To study safety, feasibility, and biologic activity of adenovirus-mediated p53 gene transfer in patients with bladder cancer. PATIENTS AND METHODS: Twelve patients with histologically confirmed bladder cancer scheduled for cystectomy were treated on day 1 with a single intratumoral injection of SCH 58500 (rAd/p53) at cystoscopy at one dose level (7.5 × 1011 particles) or a single intravesical instillation of SCH 58500 with a transduction-enhancing agent (Big CHAP) at three dose levels (7.5 × 1011 to 7.5 × 1013 particles). Cystectomies were performed in 11 patients on day 3, and transgene expression, vector distribution, and biologic markers of transgene activity were assessed by m…
Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla
2009
Summary Objective The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). Methods The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia…
Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed magnetic resonance imaging sequence with short acquisiti…
1998
A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distribution patterns of patellar cartilage thickness in the living on the basis of a fat-suppressed magnetic resonance imaging sequence with a short acquisition time and three-dimensional digital data processing. The knees of eight healthy volunteers were transversally imaged with a fat-suppressed FLASH-3D (fast low angle shot) sequence (acquisition time: 4 minutes and 10 seconds). In each case, the joint…
Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.
1997
Abstract Data on articular cartilage thickness in the living are important for the design of computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during arthroscopy. A non-invasive method for measuring cartilage thickness in living subjects is, however, not available. A technique based on magnetic resonance imaging has therefore been tested for assessing articular cartilage thickness throughout joint surfaces. The accuracy is determined by comparing cartilage thickness maps obtained from three patellar specimens with a…