Search results for "Enhancement"
showing 10 items of 566 documents
Value of echocardiography in patient follow-up after surgically corrected type A aortic dissection.
2001
Background To identify patients (pts) at risk of late complications, follow-up after surgery for type A aortic dissection is essential. We assessed the value of echocardiography to monitor patients after surgery for type A aortic dissection. Methods 80 out of 108 pts operated between 1989 and 1999 for type A aortic dissection survived surgery. 62 pts with at least one TEE, CT or MRI examinations during follow-up were included in this study. All pts had transthoracic echocardiography (TTE), 53 transesophageal echocardiography (TEE), 51 had CT, and 39 had MRI. Results At the first follow-up, 12 of 48 pts with aortic valve sparing surgery presented with aortic insufficiency >I degrees detected…
Nanocomplexes for gene therapy of respiratory diseases: Targeting and overcoming the mucus barrier
2015
Gene therapy, i.e. the delivery and expression of therapeutic genes, holds great promise for congenital and acquired respiratory diseases. Non-viral vectors are less toxic and immunogenic than viral vectors, although they are characterized by lower efficiency. However, they have to overcome many barriers, including inflammatory and immune mediators and cells. The respiratory and airway epithelial cells, the main target of these vectors, are coated with a layer of mucus, which hampers the effective reaching of gene therapy vectors carrying either plasmid DNA or small interfering RNA. This barrier is thicker in many lung diseases, such as cystic fibrosis. This review summarizes the most impor…
Atypical liver hemangiomas: contrast enhancement patterns with SH U 508A and pulse inversion ultrasound
2003
Effects of heavy barbell hip thrust vs back squat on subsequent sprint performance in rugby players
2020
The objective of this research was to compare the effect of Post-Activation Performance Enhancement (PAPE) exerted on the back squat (BS) versus the barbell hip thrust (HT) on the sprint performance (5- and 10-m). 17 male amateur rugby players participated in the study (age 22.14 ± 2.52 years; body mass 81.06 ± 9.6 kg; height 1.78 ± 0.05 m). All participants performed a dynamic maximum strength test (3RM) in BS and HT at maximum speed. Two randomized sessions were performed inducing PAPE using BS or HT trough three series with three repetitions at 85% 1RM eight minutes before the sprint tests. An ANOVA of repeated measurement, found no differences in the time for 5-m (F = 0.398, P = 0.537, …
SPET/CT image co-registration in the abdomen with a simple and cost-effective tool
2002
Fusion of morphology and function has been shown to improve diagnostic accuracy in many clinical circumstances. Taking this into account, a number of instruments combining computed tomography (CT) with positron emission tomography (PET) or single-photon emission tomography (SPET) are appearing on the market. The aim of this study was to evaluate a simple and cost-effective approach to generate fusion images of similar quality. For the evaluation of the proposed approach, patients with neuroendocrine abdominal tumours with liver metastases were chosen, since the exact superimposition in the abdomen is more difficult than in other regions. Five hours following the injection of 110 MBq (111)In…
Optimization of fluorescence enhancement for silicon-based microarrays
2008
An optical technique for the enhancement of fluorescence detection sensitivity on planar samples is presented. Such a technique is based on the simultaneous optimization of excitation and light collection by properly combining interference and reflectance from the sample holder. Comparative tests have been performed in microarray applications, by evaluating the proposed solution against commercial glass-based devices, using popular labeling dyes, such as Cy3 and Cy5. The proposed technique is implemented on a substrate built with standard silicon technology and is therefore well suited for integrated micro total analysis systems (microTAS) applications.
Evaluation of DR and CR digital mammography systems based on phantom and breast dosimetry.
2006
Digital mammography has been progressively introduced in screening centers, since recent evolution of CR and DR detectors. However, it is questionable which exposure conditions would be more suitable when these techniques are applied, in order to reduce the glandular breast doses, as they are related with induced carcinogenesis. Several exposures have been performed in CR and DR mammography units for comparing absorbed doses during quality control assessments and during screening, diagnosis and treatment. In the first case, the CIRS11A mammographic phantom has been used with standard exposure conditions (28 kV, AEC mode with blackening +0, 50:50 glandularity and 4.5 compressed breast thickn…
The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.
2011
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…
Left ventricular hypertrophy or storage disease? the incremental value of speckle tracking strain bull's-eye
2017
Left ventricular hypertrophy (LVH) develops in response to a variety of physical, genetic, and biochemical stimuli and represents the early stage of ventricular remodeling. In patients with LVH, subclinical left ventricular (LV) dysfunction despite normal ejection fraction (EF) may be present before the onset of symptoms, which portends a dismal prognosis. Strain measurement with two-dimensional speckle tracking echocardiography (STE) represents a highly reproducible and accurate alternative to LVEF determination. The present review focuses on current available evidence that supports the incremental value of STE in the diagnostic and prognostic workup of LVH. When assessing the components o…
Small Bowel Perforations: What the Radiologist Needs to Know
2016
The incidence of small bowel perforation is low but can develop from a variety of causes including Crohn disease, ischemic or bacterial enteritis, diverticulitis, bowel obstruction, volvulus, intussusception, trauma, and ingested foreign bodies. In contrast to gastroduodenal perforation, the amount of extraluminal air in small bowel perforation is small or absent in most cases. This article will illustrate the main aspects of small bowel perforation, focusing on anatomical reasons of radiological findings and in the evaluation of the site of perforation using plain film, ultrasound, and multidetector computed tomography equipments. In particular, the authors highlight the anatomic key notes…