Search results for "Equipment Design"
showing 10 items of 409 documents
Silencing and enhancement of second-harmonic generation in optical gap antennas
2012
International audience; Amplifying local electromagnetic fields by engineering optical interactions between individual constituents of an optical antenna is considered fundamental for efficient nonlinear wavelength conversion in nanometer-scale devices. In contrast to this general statement we show that high field enhancement does not necessarily lead to an optimized nonlinear activity. In particular, we demonstrate that second-harmonic responses generated at strongly interacting optical gap antennas can be significantly suppressed. Numerical simulations are confirming silencing of second-harmonic in these coupled systems despite the existence of local field amplification. We then propose a…
Dielectrophoretic trapping of multilayer DNA origami nanostructures and DNA origami-induced local destruction of silicon dioxide
2015
DNA origami is a widely used method for fabrication of custom-shaped nanostructures. However, to utilize such structures, one needs to controllably position them on nanoscale. Here we demonstrate how different types of 3D scaffolded multilayer origamis can be accurately anchored to lithographically fabricated nanoelectrodes on a silicon dioxide substrate by DEP. Straight brick-like origami structures, constructed both in square (SQL) and honeycomb lattices, as well as curved "C"-shaped and angular "L"-shaped origamis were trapped with nanoscale precision and single-structure accuracy. We show that the positioning and immobilization of all these structures can be realized with or without thi…
Endoscopic surgery of the rhinobasis with a computer-assisted localizer
1996
The endoscope is useful for the diagnosis and surgical therapy of diseases of the nose, the paranasal sinuses and its neighboring regions, and allows for microinvasive, functional approaches. The reduced invasiveness of therapeutic procedures is sometimes accompanied by insufficient clearness of the surgical field, however. This significant problem is solved by the computer-assisted-surgery (CAS) system, an intraoperative localizer. It allows continuous orientation based on three-dimensional reconstructed preoperative CT scans with superimposed positioning of the endoscope. We have now adapted CAS for endoscopic sinus surgery, which meant that a variety of visualization methods were tested.…
Advances in endoscopic imaging of colorectal neoplasia.
2010
Colon cancer screening is arguably the most important activity performed by gastroenterologists. Recent decreases in rates of death from colorectal cancer indicate that screening methods such as colonoscopy have a positive impact. There is still room for improvement, however, particularly in prevention of right-sided colon cancer. Practice issues, such as making colonoscopy more comfortable, safer, and less costly, are keys to continued success in cancer prevention. Colonoscopy techniques, technologies, and quality control measures have advanced to improve detection, classification, and removal of early neoplasias. In particular, slow, careful inspection of the colon by gastroenterologists …
Energy-saving analysis of hydraulic hybrid excavator based on common pressure rail
2013
Published version of an article in the journal: The Scientific World Journal. Also available from the publisher at: http://dx.doi.org/10.1155/2013/560694 Open Access Energy-saving research of excavators is becoming one hot topic due to the increasing energy crisis and environmental deterioration recently. Hydraulic hybrid excavator based on common pressure rail (HHEC) provides an alternative with electric hybrid excavator because it has high power density and environment friendly and easy to modify based on the existing manufacture process. This paper is focused on the fuel consumption of HHEC and the actuator dynamic response to assure that the new system can save energy without sacrificin…
A mixed FES/EMG system for real time analysis of muscular fatigue
2010
International audience; In this article, we present a functional electrical stimulator allowing the extraction in real time of M-wave characteristics from resulting EMG recodings in order to quantify muscle fatigue. This system is composed of three parts. A Labview software managing the stimulation output and electromyogram (EMG) input signal, a hardware part amplifying the output and input signal and a link between the two previous parts which is made up from input/output module (NIdaq USB 6251). In order to characterize the fatigue level, the Continuous Wavelet Transform is applied yielding a local maxima detection. The fatigue is represented on a scale from 0 for a fine shaped muscle to …
Multi-objective optimization of nitinol stent design.
2017
Nitinol stents continuously experience loadings due to pulsatile pressure, thus a given stent design should possess an adequate fatigue strength and, at the same time, it should guarantee a sufficient vessel scaffolding. The present study proposes an optimization framework aiming at increasing the fatigue life reducing the maximum strut strain along the structure through a local modification of the strut profile.The adopted computational framework relies on nonlinear structural finite element analysis combined with a Multi Objective Genetic Algorithm, based on Kriging response surfaces. In particular, such an approach is used to investigate the design optimization of planar stent cell.The r…
A microcontroller-based portable electrocardiograph recorder.
2004
We describe a low cost portable Holler design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.
Simple equipment to measure biomechanical quantities of muscles and organs which includes a polarity-programmable peak detector
1982
Biomechanical measurements of muscles and organs require appropriate measuring equipment. As far as the static properties are concerned, the excursion of the bender bar of stress should be without force. The bender bar of force, however, ideally should not elongate under load. Because natural frequency is the most important boundary condition, the bender bar should be developed with this in mind. The developed bars imposed an insignificant preload to the muscle or to the organ. The small changes in resistance occurring in the resistance strain gauges affixed to the bars require the use of a highly stable amplifier. A new amplifier was accordingly developed based on the principle of an instr…
Instrumentation, control, and automation for submerged anaerobic membrane bioreactors
2015
A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…