Shock-wave therapy for tennis and golfer's elbow - 1 year follow-up
1999
Thirty patients with chronic medial epicondylitis were treated with low-energy shock waves. They received 500 impulses of 0.08 mJ/mm2 three times at weekly intervals. At 1 year follow-up examinations were performed. According to the Verhaar criteria, only seven patients reached excellent or good results. In eight cases a fair outcome was recorded, and in 14 patients the outcome was poor. Only six patients were satisfied with the treatment. The average relief of pain was 32%. These data were significantly worse than for identically treated patients with chronic tennis elbow. Thus, the question arises as to whether extracorporal shock-wave therapy is indicated in medial epicondylitis.
Liver assessment and biopsy in patients with marked coagulopathy: value of mini-laparoscopy and control of bleeding.
2003
Evaluation of liver disease in patients with a high risk of postbiopsy bleeding presents a diagnostic challenge. Mini-laparoscopy offers the possibility of coagulation of biopsy site and the additional advantage of macroscopic liver assessment. We wished to assess the value and safety of mini-laparoscopy with guided biopsy as a diagnostic approach in patients in whom percutaneous liver biopsy is considered contraindicated because of a marked coagulopathy.We investigated 61 consecutive patients with marked coagulopathy (prolonged international normalized ratio1.5, thrombocytopenia50/nl, or both; von Willebrand's disease/hemophilia). Diagnostic mini-laparoscopy with visually guided liver biop…
Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents.
1993
AbstractObjectives. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome.Background. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference,Methods. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area.Results. Analysis was pe…
Force in the Achilles Tendon During Walking With Ankle Foot Orthosis
2009
Background Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design Controlled laboratory study. Methods In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positi…
Effect of bike-fit in the perception of comfort, fatigue and pain
2016
The aim of this study was to assess the influence of different bike positions on the perception of fatigue, pain and comfort. Twenty cyclists underwent three tests that involved cycling for 45 min at their individual 50% peak aerobic power output while adopting different positions on the bike. Participants performed the cycling tests adopting three positions defined by two parameters (knee flexion angle [20°, 30°, 40°] and trunk flexion angle [35°, 45°, 55°]) in random order. Angles were measured using a 2D motion analysis system during cycling and applying Fonda's correction factor. Perceptions of comfort, fatigue and pain were reported before the end of each test. The combination of 40° k…
Inability of Laplace's law to estimate sub-bandage pressures after applying a compressive bandage: a clinical study
2021
Objective: The aim of the current study was to compare pressures exerted on the lower limb by a high compression bandage as recorded by sub-bandage sensors and those estimated by Laplace's law. The correlation between pressures obtained in each anatomical zone and the corresponding limb perimeters were explored. Method: For the measurement of sub-bandage pressures, four anatomical zones in the lower right limb were determined. Pressures were recorded by nine pneumatic sensors and a PicoPress transducer. A two-layer compression bandage system (UrgoK2, Urgo Group, France) was used for the dressing. Pressures were registered in supine position. Sensor pressures were compared with those estimat…
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Heated breathing tubes affect humidity output of circle absorber systems.
1993
Abstract Study Objective: To verify whether the airway climate in circle systems can be improved with heated breathing tubes. Design: Randomized, controlled, prospective clinical study. Setting: Operating theater of the Department of Maxillofacial Surgery. Patients: 26 adult patients undergoing prolonged anesthesia. Interventions: A total of 26 prolonged anesthetics were conducted in adult patients using a minimal fresh gas flow rate (0.6 L/min) and silicon breathing tubes (16 mm internal diameter) containing a heated coil. Group 1 ( n = 10 patients) was the control group; breathing tubes were unheated. In Group 2 ( n = 10 patients), breathing tubes were heated to 30°C. In Group 3 ( n = 6 p…
Photobleaching effects onin vivoskin autofluorescence lifetime
2015
The autofluorescence lifetime of healthy human skin was measured using excitation provided by a picosecond diode laser operating at a wavelength of 405 nm and with fluorescence emission collected at 475 and 560 nm. In addition, spectral and temporal responses of healthy human skin and intradermal nevus in the spectral range 460 to 610 nm were studied before and after photobleaching. A decrease in the autofluorescences lifetimes changes was observed after photobleaching of human skin. A three-exponential model was used to fit the signals, and under this model, the most significant photoinduced changes were observed for the slowest lifetime component in healthy skin at the spectral range 520 …
Clinical validation of embryo culture and selection by morphokinetic analysis: a randomized, controlled trial of the EmbryoScope.
2014
Objective To determine whether incubation in the integrated EmbryoScope time-lapse monitoring system (TMS) and selection supported by the use of a multivariable morphokinetic model improve reproductive outcomes in comparison with incubation in a standard incubator (SI) embryo culture and selection based exclusively on morphology. Design Prospective, randomized, double-blinded, controlled study. Setting University-affiliated private in vitro fertilization (IVF) clinic. Patient(s) Eight hundred forty-three infertile couples undergoing intracytoplasmic sperm injection (ICSI). Intervention(s) No patient intervention; embryos cultured in SI with development evaluated only by morphology (control …