Search results for "Equipment Failure Analysi"

showing 10 items of 123 documents

"Photonic lantern" spectral filters in multi-core fibre

2012

Fiber Bragg gratings are written across all 120 single-mode cores of a multi-core optical Fiber. The Fiber is interfaced to multimode ports by tapering it within a depressed-index glass jacket. The result is a compact multimode "photonic lantern" filter with astrophotonic applications. The tapered structure is also an effective mode scrambler.

Mode scramblerPHOSFOSMulti-mode optical fiberOptical fiberMaterials sciencebusiness.industryAstrophysics::Instrumentation and Methods for AstrophysicsPhysics::OpticsEquipment DesignAtomic and Molecular Physics and Opticslaw.inventionSubwavelength-diameter optical fibreEquipment Failure AnalysisOpticsFiber Bragg gratinglawOptoelectronicsComputer-Aided DesignPhotonicsbusinessFiltrationOptical FibersPhotonic-crystal fiber
researchProduct

Negative differential resistance in carbon nanotube field-effect transistors with patterned gate oxide.

2010

We demonstrate controllable and gate-tunable negative differential resistance in carbon nanotube field-effect transistors, at room temperature and at 4.2 K. This is achieved by effectively creating quantum dots along the carbon nanotube channel by patterning the underlying, high-kappa gate oxide. The negative differential resistance feature can be modulated by both the gate and the drain-source voltage, which leads to more than 20% change of the current peak-to-valley ratio. Our approach is fully scalable and opens up a possibility for a new class of nanoscale electronic devices using negative differential resistance in their operation.

NanostructureMaterials scienceTransistors ElectronicMacromolecular SubstancesSurface PropertiesMolecular ConformationGeneral Physics and AstronomyNanotechnologyCarbon nanotubelaw.inventionComputer Science::Emerging TechnologiesGate oxidelawMaterials TestingElectric ImpedanceNanotechnologyGeneral Materials ScienceParticle SizeTransistorGeneral EngineeringOxidesEquipment DesignCondensed Matter::Mesoscopic Systems and Quantum Hall EffectNanostructuresEquipment Failure AnalysisHysteresisQuantum dotField-effect transistorCrystallizationVoltageACS nano
researchProduct

Self-phase modulation-based 2R regenerator including pulse compression and offset filtering for 42.6 Gbit/s RZ-33% transmission systems

2009

International audience; We report on the experimental and theoretical study of a self-phase-modulation-based regenerator at 42.6 Gbit/s with a return-to-zero 33% format. We point out some detrimental effects such as intrachannel interactions and Brillouin scattering. An efficient solution, relying on a self-phase-modulation-based pulse compressor in combination with the regenerator, is proposed to overcome these detrimental phenomena. The experimental demonstration shows the effectiveness of a wavelength-transparent regenerator at 42.6 Gbit/s with a sensitivity-improvement of more than 5 dB and an eye-opening improvement of 2.3 dB in a back-to-back configuration, as well as a 10 times maxim…

Offset (computer science)Materials science060.2330 ; 070.4340 ; 190.3270 ; 190.438002 engineering and technologyMamyshev 2R regeneratorSensitivity and Specificity01 natural sciences010309 optics020210 optoelectronics & photonicsOpticsBrillouin scattering0103 physical sciences0202 electrical engineering electronic engineering information engineeringComputer SimulationMicrowavesSelf-phase modulationOptical amplifierbusiness.industryCross-phase modulationOptical DevicesReproducibility of ResultsEquipment DesignModels TheoreticalAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryPulse compressionRegenerative heat exchangerTelecommunicationsComputer-Aided DesignbusinessFiltration
researchProduct

Soft proton exchanged channel waveguides in congruent lithium tantalate for frequency doubling

2010

We report on stable optical waveguides fabricated by soft-proton exchange in periodically-poled congruent lithium tantalate in the a-phase. The channel waveguides are characterized in the telecom wavelength range in terms of both linear properties and frequency doubling. The measurements yield a nonlinear coefficient of about 9.5pm/V, demonstrating that the nonlinear optical properties of lithium tantalate are left nearly unaltered by the process. (C) 2010 Optical Society of America

Optical frequency multiplierMaterials scienceProtonPhysics::OpticsTantalumLithiumNonlinear opticalchemistry.chemical_compoundOpticsbusiness.industrySecond-harmonic generationOxidesEquipment DesignSurface Plasmon ResonanceAtomic and Molecular Physics and OpticsEquipment Failure AnalysisNonlinear systemRefractometrychemistryNonlinear DynamicsYield (chemistry)Lithium tantalateComputer-Aided DesignChannel (broadcasting)ProtonsbusinessNonlinear optics Integrated optics materials Waveguides Nonlinear optical devices
researchProduct

Microstructure alterations of rotary files after multiple simulated operative procedures.

2009

Aim: To assess morphological alterations of ProTaper rotary NiTi files before and after continuous use by scanning electron microscopy (SEM). Study Design: 30 root canals were chosen with an angle between 15 and 30º. Before starting to prepare the canals the files were observed microscopically using a scanning electronic microscope. The ProTaper sequence recommended by the manufacturer was used, with NaOCl as irrigant. The instruments were sterilised after every three canals were shaped. The instruments were observed with the same microscope after shaping each canal, until 30 root canals were shaped. The criteria used for checking the instruments were: blunt cutting edges, disruption of cut…

OrthodonticsMicroscopeMaterials scienceEdge (geometry):CIENCIAS MÉDICAS [UNESCO]MicrostructureMolarlaw.inventionRoot Canal TherapyEquipment Failure AnalysisOtorhinolaryngologyContinuous uselawNickel titaniumUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningHumansSurgeryGeneral DentistryMedicina oral, patologia oral y cirugia bucal
researchProduct

Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern

2011

We present a novel technique for remote noncontact blood pulse pressure measurement. It is based on tracking both temporal and amplitude changes of reflected secondary speckle produced in human skin when illuminated by a laser beam. The implemented technique extracts the difference between the systolic and the diastolic blood pressure. Experimental results are presented showing good agreement when compared with conventional measurement methods.

Pathologymedicine.medical_specialtyMaterials scienceBiomedical EngineeringHemodynamicsSensitivity and SpecificityPattern Recognition Automatedlaw.inventionPhotometryBiomaterialsPhotometry (optics)Speckle patternOpticslawmedicineHumansLaser beamsbusiness.industryLasersReproducibility of ResultsBlood Pressure DeterminationEquipment DesignLaserAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsPulse pressureEquipment Failure AnalysisAmplitudeBlood pressureRemote Sensing Technologysense organsbusinessJournal of Biomedical Optics
researchProduct

Twofold coordinated Ge defects induced by gamma-ray irradiation in Ge-doped SiO2

2008

We report an experimental study by photoluminescence, optical absorption and Electron Paramagnetic Resonance measurements on the effects of exposure of Ge-doped amorphous SiO2 to gamma ray radiation at room temperature. We have evidenced that irradiation at doses of the order of 1 MGy is able to generate Ge-related defects, recognizable from their optical properties as twofold coordinated Ge centers. Until now, such centers, responsible for photosensitivity of Ge-doped SiO2, have been induced only in synthesis procedures of materials. The found result evidences a role played by gamma radiation in generating photosensitive defects and could furnish a novel basis for photosensitive pattern wr…

PhotoluminescenceMaterials sciencesistemi amorfi difetti di puntoRadiationIonizing radiationlaw.inventionOpticsPhotosensitivitylawFiber Optic TechnologyComputer SimulationIrradiationElectron paramagnetic resonanceGe defectsLightingbusiness.industryGermaniumGamma rayEquipment DesignModels TheoreticalSilicon DioxideAtomic and Molecular Physics and OpticsAmorphous solidEquipment Failure AnalysisGamma Raysgamma-ray irradiationComputer-Aided DesignSiO2business
researchProduct

The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.

2014

Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…

PhotonQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsMonte Carlo methodAnalytical chemistryBoron Neutron Capture TherapySensitivity and SpecificityOpticsNuclear ReactorsDosimetryPenelopeIonization ChamberDosimetryComputer SimulationPhoton beamRadiometryMonte CarloPhysicsPhotonsRadiationModels Statisticalbusiness.industryAirRadiotherapy Planning Computer-AssistedReproducibility of ResultsEquipment DesignNeutron radiationEquipment Failure AnalysisIonization chamberBNCTPhysics::Accelerator PhysicsComputer-Aided DesignDose ratebusinessMCNP5Beam (structure)Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Nanoassembled plasmonic-photonic hybrid cavity for tailored light-matter coupling.

2010

We propose and demonstrate a hybrid cavity system in which metal nanoparticles are evanescently coupled to a dielectric photonic crystal cavity using a nanoassembly method. While the metal constituents lead to strongly localized fields, optical feedback is provided by the surrounding photonic crystal structure. The combined effect of plasmonic field enhancement and high quality factor (Q approximately 900) opens new routes for the control of light-matter interaction at the nanoscale.

PhotonsNanostructureMaterials sciencebusiness.industryMechanical EngineeringTransducersPhysics::OpticsNanoparticleBioengineeringNanotechnologyGeneral ChemistryDielectricEquipment DesignSurface Plasmon ResonanceCondensed Matter PhysicsEquipment Failure AnalysisCoupling (physics)RefractometryNanotechnologyGeneral Materials SciencePhotonicsbusinessNanoscopic scalePlasmonPhotonic crystalNano letters
researchProduct

Cantor Dust Zone Plates

2013

In this paper we use the Cantor Dust to design zone plates based on a two-dimensional fractal for the first time. The pupil function that defines the coined Cantor Dust Zone Plates (CDZPs) can be written as a combination of rectangle functions. Thus CDZPs can be considered as photon sieves with rectangular holes. The axial irradiances produced by CDZPs of different fractal orders are obtained analitically and experimentally, analyzing the influence of the fractality. The transverse irradiance patterns generated by this kind of zone plates has been also investigated.

PhysicsDiffractionPhotonFresnel zoneLightbusiness.industryEquipment DesignModels TheoreticalPHOTON SIEVESAtomic and Molecular Physics and OpticsCantor setEquipment Failure AnalysisTransverse planeRefractometryFractalOpticsFISICA APLICADAPupil functionScattering RadiationComputer SimulationAstrophysics::Earth and Planetary AstrophysicsRectanglebusinessMATEMATICA APLICADA
researchProduct