Search results for "Failure analysis"

showing 10 items of 132 documents

Microstructure alterations of rotary files after multiple simulated operative procedures.

2009

Aim: To assess morphological alterations of ProTaper rotary NiTi files before and after continuous use by scanning electron microscopy (SEM). Study Design: 30 root canals were chosen with an angle between 15 and 30º. Before starting to prepare the canals the files were observed microscopically using a scanning electronic microscope. The ProTaper sequence recommended by the manufacturer was used, with NaOCl as irrigant. The instruments were sterilised after every three canals were shaped. The instruments were observed with the same microscope after shaping each canal, until 30 root canals were shaped. The criteria used for checking the instruments were: blunt cutting edges, disruption of cut…

OrthodonticsMicroscopeMaterials scienceEdge (geometry):CIENCIAS MÉDICAS [UNESCO]MicrostructureMolarlaw.inventionRoot Canal TherapyEquipment Failure AnalysisOtorhinolaryngologyContinuous uselawNickel titaniumUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningHumansSurgeryGeneral DentistryMedicina oral, patologia oral y cirugia bucal
researchProduct

Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern

2011

We present a novel technique for remote noncontact blood pulse pressure measurement. It is based on tracking both temporal and amplitude changes of reflected secondary speckle produced in human skin when illuminated by a laser beam. The implemented technique extracts the difference between the systolic and the diastolic blood pressure. Experimental results are presented showing good agreement when compared with conventional measurement methods.

Pathologymedicine.medical_specialtyMaterials scienceBiomedical EngineeringHemodynamicsSensitivity and SpecificityPattern Recognition Automatedlaw.inventionPhotometryBiomaterialsPhotometry (optics)Speckle patternOpticslawmedicineHumansLaser beamsbusiness.industryLasersReproducibility of ResultsBlood Pressure DeterminationEquipment DesignLaserAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsPulse pressureEquipment Failure AnalysisAmplitudeBlood pressureRemote Sensing Technologysense organsbusinessJournal of Biomedical Optics
researchProduct

Twofold coordinated Ge defects induced by gamma-ray irradiation in Ge-doped SiO2

2008

We report an experimental study by photoluminescence, optical absorption and Electron Paramagnetic Resonance measurements on the effects of exposure of Ge-doped amorphous SiO2 to gamma ray radiation at room temperature. We have evidenced that irradiation at doses of the order of 1 MGy is able to generate Ge-related defects, recognizable from their optical properties as twofold coordinated Ge centers. Until now, such centers, responsible for photosensitivity of Ge-doped SiO2, have been induced only in synthesis procedures of materials. The found result evidences a role played by gamma radiation in generating photosensitive defects and could furnish a novel basis for photosensitive pattern wr…

PhotoluminescenceMaterials sciencesistemi amorfi difetti di puntoRadiationIonizing radiationlaw.inventionOpticsPhotosensitivitylawFiber Optic TechnologyComputer SimulationIrradiationElectron paramagnetic resonanceGe defectsLightingbusiness.industryGermaniumGamma rayEquipment DesignModels TheoreticalSilicon DioxideAtomic and Molecular Physics and OpticsAmorphous solidEquipment Failure AnalysisGamma Raysgamma-ray irradiationComputer-Aided DesignSiO2business
researchProduct

The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.

2014

Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…

PhotonQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsMonte Carlo methodAnalytical chemistryBoron Neutron Capture TherapySensitivity and SpecificityOpticsNuclear ReactorsDosimetryPenelopeIonization ChamberDosimetryComputer SimulationPhoton beamRadiometryMonte CarloPhysicsPhotonsRadiationModels Statisticalbusiness.industryAirRadiotherapy Planning Computer-AssistedReproducibility of ResultsEquipment DesignNeutron radiationEquipment Failure AnalysisIonization chamberBNCTPhysics::Accelerator PhysicsComputer-Aided DesignDose ratebusinessMCNP5Beam (structure)Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Nanoassembled plasmonic-photonic hybrid cavity for tailored light-matter coupling.

2010

We propose and demonstrate a hybrid cavity system in which metal nanoparticles are evanescently coupled to a dielectric photonic crystal cavity using a nanoassembly method. While the metal constituents lead to strongly localized fields, optical feedback is provided by the surrounding photonic crystal structure. The combined effect of plasmonic field enhancement and high quality factor (Q approximately 900) opens new routes for the control of light-matter interaction at the nanoscale.

PhotonsNanostructureMaterials sciencebusiness.industryMechanical EngineeringTransducersPhysics::OpticsNanoparticleBioengineeringNanotechnologyGeneral ChemistryDielectricEquipment DesignSurface Plasmon ResonanceCondensed Matter PhysicsEquipment Failure AnalysisCoupling (physics)RefractometryNanotechnologyGeneral Materials SciencePhotonicsbusinessNanoscopic scalePlasmonPhotonic crystalNano letters
researchProduct

Cantor Dust Zone Plates

2013

In this paper we use the Cantor Dust to design zone plates based on a two-dimensional fractal for the first time. The pupil function that defines the coined Cantor Dust Zone Plates (CDZPs) can be written as a combination of rectangle functions. Thus CDZPs can be considered as photon sieves with rectangular holes. The axial irradiances produced by CDZPs of different fractal orders are obtained analitically and experimentally, analyzing the influence of the fractality. The transverse irradiance patterns generated by this kind of zone plates has been also investigated.

PhysicsDiffractionPhotonFresnel zoneLightbusiness.industryEquipment DesignModels TheoreticalPHOTON SIEVESAtomic and Molecular Physics and OpticsCantor setEquipment Failure AnalysisTransverse planeRefractometryFractalOpticsFISICA APLICADAPupil functionScattering RadiationComputer SimulationAstrophysics::Earth and Planetary AstrophysicsRectanglebusinessMATEMATICA APLICADA
researchProduct

High-visibility interference fringes with femtosecond laser radiation.

2009

We propose and experimentally demonstrate an interferometer for femtosecond pulses with spectral bandwidth about 100 nm. The scheme is based on a Michelson interferometer with a dispersion compensating module. A diffractive lens serves the purpose of equalizing the optical-path-length difference for a wide range of frequencies. In this way, it is possible to register high-contrast interference fringes with micrometric resolution over the whole area of a commercial CCD sensor for broadband femtosecond pulses.

PhysicsFemtosecond pulse shapingbusiness.industryLasersAstrophysics::Instrumentation and Methods for AstrophysicsPhysics::OpticsMichelson interferometerEquipment DesignInterference (wave propagation)Atomic and Molecular Physics and Opticslaw.inventionEquipment Failure AnalysisInterferometryRefractometryOpticsInterferometrylawFemtosecondDispersion (optics)OptoelectronicsComputer-Aided DesignbusinessDiffraction gratingCoherence (physics)LensesOptics express
researchProduct

In vitro power profiles of multifocal simultaneous vision contact lenses.

2013

Abstract Purpose To evaluate the power profile of multifocal contact lenses (CLs) using a new technology based on quantitative deflectometry. Methods The Nimo TR1504 was used to analyze the power distribution of multifocal CLs. The CLs under study were: Air Optix Aqua Multifocal Low, Medium and High Addition and Focus Progressives. Three lenses of each model were considered. Results All multifocal CLs showed a power profile characterized by a change toward more positive power values when aperture sizes become smaller. The near refractive addition of the lenses under study was +2.61 D, +1.44 D, +1.30 D and +0.30 D for the Focus Progressives, the Air Optix Aqua Multifocal High, Medium Add and…

PhysicsLightbusiness.industryApertureContact LensesOptical powerGeneral MedicinePresbyopiaEquipment Designmedicine.diseaseDistance correctionlaw.inventionPower (physics)Lens (optics)Equipment Failure AnalysisOphthalmologyRefractometryOpticslawmedicineScattering RadiationbusinessFocus (optics)OptometryNominal power (photovoltaic)Contact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Superresolution digital holographic microscopy for three-dimensional samples.

2009

An approach that allows superresolution imaging of three-dimensional (3-D) samples by numerical refocusing is presented in the field of digital holographic microscopy. Based on the object's spectrum shift produced by tilted illumination, we present a time multiplexing superresolved approach to overcome the Abbe's diffraction limit. The proposed approach uses a microscope in a Mach-Zehnder interferometric architecture with the particularity that the output plane does not coincide with the image plane. Thus, a set of off-axis non-image plane holograms are sequentially recorded for every tilted beam used in the illumination stage. After that and by using simple digital post-processing and nume…

PhysicsMicroscopyMicroscopebusiness.industryHolographyPhysics::OpticsReproducibility of ResultsSignal Processing Computer-AssistedEquipment DesignImage planeImage EnhancementSensitivity and SpecificityAtomic and Molecular Physics and Opticslaw.inventionLens (optics)Equipment Failure AnalysisInterferometryOpticsImaging Three-DimensionallawMicroscopyDigital holographic microscopybusinessDigital holographyOptics express
researchProduct

Magnetic dipole with a flexible tail as a self-propelling microdevice.

2012

By numerical simulations, it is illustrated that a magnetic dipole with a flexible tail behaves as a swimmer in AC magnetic fields. The behavior of the swimmer on long time scales is analyzed and it is shown that due to the flexibility of the tail two kinds of torques arise, the first is responsible for the orientation of the swimmer perpendicularly to the AC field and the second drags the filament in the direction of the rotating field. Due to this, circular trajectories of the swimmer are possible; however, these are unstable. The self-propulsion velocity of this swimmer is higher than the velocities of other magnetic microdevices for comparable values of the magnetoelastic number.

PhysicsPhysics::Biological PhysicsFlexibility (anatomy)MiniaturizationField (physics)MechanicsEquipment DesignRoboticsQuantitative Biology::OtherQuantitative Biology::Cell BehaviorMagnetic fieldProtein filamentEquipment Failure AnalysisMagneticsMotionmedicine.anatomical_structureMagnetic FieldsOrientation (geometry)medicinePerpendicularTorqueMagnetic dipolePhysical review. E, Statistical, nonlinear, and soft matter physics
researchProduct