Search results for "Fields"
showing 10 items of 575 documents
Fast photon detection for particle identification with COMPASS RICH-1
2006
Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several $10^6$ per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The ne…
First M87 Event Horizon Telescope Results. VIII. Magnetic Field Structure near The Event Horizon
2021
Full list of authors: Akiyama, Kazunori; Algaba, Juan Carlos; Alberdi, Antxon; Alef, Walter; Anantua, Richard; Asada, Keiichi; Azulay, Rebecca; Baczko, Anne-Kathrin; Ball, David; Baloković, Mislav; Barrett, John; Benson, Bradford A.; Bintley, Dan; Blackburn, Lindy; Blundell, Raymond; Boland, Wilfred; Bouman, Katherine L.; Bower, Geoffrey C.; Boyce, Hope Bremer, Michael; Brinkerink, Christiaan D.; Brissenden, Roger; Britzen, Silke; Broderick, Avery E.; Broguiere, Dominique; Bronzwaer, Thomas; Byun, Do-Young; Carlstrom, John E.; Chael, Andrew; Chan, Chi-kwan; Chatterjee, Shami; Chatterjee, Koushik; Chen, Ming-Tang; Chen, Yongjun; Chesler, Paul M.; Cho, Ilje; Christian, Pierre; Conway, John E.…
3d-Mapping Of Multiple Mirror Sources In A Room: A Two Channel Intensimetric Method.
2005
A large lecture theatre was analyzed by using a 3D intensimetric measurement method. Sweep signal providing the excitation of the environment was sent to an isotropic source. Sound intensity probe was positioned in some test points of the room and sound intensity vector decay was measured for each of them. The sound board of a PC was utilized to acquire couples of impulse responses for each sound intensity vector component. These signals were combined by using an algorithm implemented in Lab VIEW. Mirror sources were localized and visualized in a three-dimensional map for each measurement point. Resuls are presented as orthogonal projections and 3D-diagrams.
Modern health worries and idiopathic environmental intolerance attributed to electromagnetic fields are associated with paranoid ideation.
2021
Paranoid ideation is assumed to characterize worries about possible harmful effects of modern technologies (MHWs) and idiopathic environmental intolerances (IEIs), such as IEI attributed to electromagnetic fields (IEI-EMF). Empirical evidence on these associations is scarce.In a cross-sectional on-line survey, participants of a community sample (n = 700; mean age: 28.4 ± 12.0; 434 females) completed the Somatosensory Amplification Scale, the Modern Health Worries Scale, and the Paranoid Ideation scale of the Symptom Checklist 90 Revised. They were considered IEI-EMF if (1) they categorized themselves so, (2) they had experienced symptoms that they attributed to the exposure to electromagnet…
Reversible effect of magnetic fields on human lymphocyte activation patterns: different sensitivity of naive and memory lymphocyte subsets.
2009
The aim of this study was to investigate the influence of 50 Hz magnetic or static magnetic fields of 0.5 mT on subsets of human CD4(+) T cells in terms of cytokine release/content, cell proliferation and intracellular free calcium concentration. CD4(+) T cells can be divided into different subsets on the basis of surface marker expression, such as CD45, and T cells can be divided into naive (CD45RA(+)) and memory (CD45RA(-)) cells. In this study, the effects of magnetic fields after 24 and 48 h of cell culture were analyzed. We found that the CD4(+)CD45RA(-) T subset were more sensitive after 2 h of exposure. Decreases in the release/content of IFN-gamma, in cell proliferation and in intra…
Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.
2001
The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…
Interhemispheric cooperation for face recognition but not for affective facial expressions
2003
Abstract Interhemispheric cooperation can be indicated by enhanced performance when stimuli are presented to both visual fields relative to one visual field alone. This “bilateral gain” is seen for words but not pseudowords in lexical decision tasks, and has been attributed to the operation of interhemispheric cell assemblies that exist only for meaningful words with acquired cortical representations. Recently, a bilateral gain has been reported for famous but not unfamiliar faces in a face recognition task [Neuropsychologia 40 (2002) 1841]. In Experiment 1 of the present paper, participants performed familiarity decisions for faces that were presented to the left (LVF), the right (RVF), or…
Eyes open and eyes closed as rest conditions: impact on brain activation patterns
2003
The patterns of associated brain activations during eyes-open and eyes-closed states in complete darkness considerably differ in fMRI. An "interoceptive" state with the eyes closed is characterized by visual cortex activation, while an "exteroceptive" state with the eyes open is characterized by ocular motor system activity. The impact of the chosen rest condition (eyes open or eyes closed in complete darkness) on the pattern of brain activations during visual stimulation was evaluated in 14 healthy volunteers. During fixation or dim light room illumination, the activation of the visual cortex was larger with the eyes-open rest condition than with the eyes-closed rest condition; however, ac…
Correlation of cerebral blood flow and treatment effects of repetitive transcranial magnetic stimulation in depressed patients.
2002
The aims of this study were to: (1) assess the effects of repetitive transcranial magnetic stimulation (rTMS) on brain activity in depressed patients as measured by single photon emission tomography (SPECT); (2) evaluate the predictive value of brain SPECT on the antidepressant efficacy of rTMS. Patients (n=17) received 1600 rTMS stimuli at a rate of 10 Hz, 5 days per week for 2 weeks to the left dorsolateral prefrontal cortex. Whole brain SPECT data were acquired using Tc99m-Bicisate. Regional cerebral blood flow (rCBF) was correlated with the % change in the 28-item Hamilton Depression Rating Scale Score (Δ-HDRS) and a semiquantitative region of interest (ROI) analysis was conducted. Prio…
Application of intermittent galvanic vestibular stimulation reveals age-related constraints in the multisensory reweighting of posture
2014
In this study we examined the effects of intermittent short-duration Galvanic Vestibular Stimulation (GVS) during a multisensory perturbation of posture in young and elderly adults. Twelve young (24.91 +/- 6.44 years) and eleven elderly (74.8 +/- 6.42 years) participants stood upright under two task conditions: (a) quiet standing and (b) standing while receiving pseudo-randomly presented bipolar 2 s GVS pulses. In both conditions, sensory reweighting was evoked by visual surround oscillations (20 cm, 0.3 Hz) and Achilles tendon vibration (3 mm, 80 Hz), concurrently delivered during the middle 60 s of standing. Intermittent GVS decreased the excessive postural sway induced by the concurrent …