Search results for "Flicker"

showing 10 items of 51 documents

Validation of the simplified Animal Naming Test as primary screening tool for the diagnosis of covert hepatic encephalopathy

2019

Diagnosis of covert hepatic encephalopathy (CHE) is time consuming in clinical practice. Recently, a new diagnostic tool - the simplified Animal Naming Test (S-ANT1) - was presented with promising results in an Italian cohort. The aim of the present study was to validate S-ANT1 in a cohort of cirrhotic patients from a German tertiary referral centre.143 cirrhotic patients and 37 healthy controls were enrolled. Hepatic encephalopathy (HE) grade 1 (HE1) was clinically diagnosed according to the West-Haven Criteria. Critical flicker frequency and Psychometric Hepatic Encephalopathy Score were used to detect minimal HE (MHE). All participants were additionally examined by S-ANT1.58 (40.6%) pati…

Liver CirrhosisMalePediatricsmedicine.medical_specialtyPsychometricsFlicker fusion thresholdNeuropsychological Tests030204 cardiovascular system & hematologyRisk AssessmentSeverity of Illness Index03 medical and health sciences0302 clinical medicineReference ValuesGermanyInternal MedicinemedicineAnimalsHumansIn patientProspective Studies030212 general & internal medicineHepatic encephalopathyAgedbusiness.industryMiddle Agedmedicine.diseaseTest (assessment)Clinical PracticeROC CurveCovertCase-Control StudiesHepatic EncephalopathyCohortFemalebusinessPrimary screeningEuropean Journal of Internal Medicine
researchProduct

Value of the critical flicker frequency in patients with minimal hepatic encephalopathy

2007

Minimal hepatic encephalopathy (MHE) is mainly diagnosed using psychometric tests such as the psychometric hepatic encephalopathy score (PHES). Despite the clinical and social relevance of MHE, psychometric testing is not widespread in routine clinical care. We assessed the usefulness of the critical flicker frequency (CFF), for the diagnosis of MHE and for the prediction of the development of overt episodes of HE. The normal range of PHES in the Spanish population was evaluated in a control group. Subsequently, 114 patients with cirrhosis and 103 healthy controls underwent both PHES and CFF tests. A diagnosis of MHE was made when the PHES was lower than −4 points. Patients were followed-up…

Liver CirrhosisMaleRiskmedicine.medical_specialtyCirrhosisEncephalopathyFlicker fusion thresholdNeuropsychological TestsGastroenterologyCentral nervous system diseaseFlicker FusionLiver diseaseInternal medicinePrevalenceMedicineHumansHepatic encephalopathyAgedHepatologybusiness.industryProportional hazards modelHepatologyMiddle Agedmedicine.diseaseSurgeryHepatic EncephalopathyFemalebusinesshuman activities
researchProduct

LED Based Dual Wavelength Heterochromatic Flicker Method for Separate Evaluation of Lutein and Zeaxanthin in Retina

2013

The decrease of density and consequentially optical density of macular pigment serves as a diagnostic mean for a number of ophthalmological pathologies, particularly as a risk factor for age related macular degeneration. Macular pigment absorbs light in short wavelength blue spectral range. Thus the optical density of macular pigment can be detected by various optical – both objective and subjective psychophysical techniques. Latter techniques use eye and brain visual pathways as spectral sensitive optical detector and decision maker, and exploit perception facility to process information flow in a unique manner to create various perception illusions. The psychophysical methods of detection…

LuteinRetinaMaterials sciencegenetic structuresbusiness.industryFlickerfood and beveragesMacular degenerationVisual systemmedicine.diseaseeye diseasesZeaxanthinPhotometry (optics)chemistry.chemical_compoundWavelengthOpticsmedicine.anatomical_structurechemistrymedicinesense organsbusiness
researchProduct

Focal cortical damage parallels cognitive impairment in minimal hepatic encephalopathy

2012

Little attention has been paid to cortical integrity in patients with minimal hepatic encephalopathy (MHE), although cognitive functions affected in early stages of liver disease are mainly allocated in different neocortical structures. Here we used cortical surface-based analysis techniques to investigate if patterns of cortical thinning accompany the mildest form of HE. To aim this goal, cortical thickness obtained from high-resolution 31 magnetic resonance imaging (MRI) was measured in patients with no MHE (NMHE), MHE, and healthy controls. Further correlation analyses were performed to examine whether scores in the critical flicker frequency (CFF) test, and blood ammonia levels accounte…

Malemedicine.medical_specialtyPathologyCognitive NeuroscienceMinimal hepatic encephalopathyPrecuneusFlicker fusion thresholdNeuropsychological TestsCortical thicknessLiver diseaseInternal medicineImage Interpretation Computer-AssistedmedicineHumansHepatic encephalopathyTemporal cortexCerebral Cortexmedicine.diagnostic_testMagnetic resonance imagingCognitionMiddle Agedmedicine.diseaseEarly diagnosisMagnetic Resonance ImagingCalcarine sulcusmedicine.anatomical_structureEarly DiagnosisCognitive impairmentNeurologyHepatic cirrhosisHepatic EncephalopathyCardiologyFemalePsychologyCognition Disordershuman activities
researchProduct

Influence of oxygen ion elementary diffusion jumps on the electron current through the conductive filament in yttria stabilized zirconia nanometer-si…

2021

Abstract The structure of the electron current through an individual filament of a nanometer-sized virtual memristor consisting of a contact of a conductive atomic force microscope probe to an yttria stabilized zirconia (YSZ) thin film deposited on a conductive substrate is investigated. Usually, such investigation is performed by the analysis of the waveform of this current with the aim to extract the random telegraph noise (RTN). Here, we suggest a new indirect method, which is based on the measurement of the spectrum of the low-frequency flicker noise in this current without extracting the RTN, taking into account the geometrical parameters of the filament. We propose that the flicker no…

Materials scienceCondensed matter physicsGeneral MathematicsApplied MathematicsGeneral Physics and AstronomyStatistical and Nonlinear PhysicsMemristor01 natural sciencesNoise (electronics)010305 fluids & plasmaslaw.inventionRoot mean squareProtein filamentlaw0103 physical sciencesFlicker noiseThin film010301 acousticsElectrical conductorYttria-stabilized zirconiaChaos, Solitons & Fractals
researchProduct

Electrical and optical low frequency noises in multimodal vertical cavity surface emitting lasers

2006

Experimental investigations of the low frequency noise of multimode 780 nm vertical cavity surface emitting lasers are reported. Electrical noise, optical noise and their correlation have been measured in the frequency range 1 Hz–95 kHz. The results show that the main contribution to the electrical noise is located in the distributed Bragg reflector layers of the laser. The optical power and pump current noise sources are strongly correlated below and around the threshold, while are weakly correlated above threshold. It is argued that the noise in the optical power is due to both free injection carrier noise and optical gain fluctuations.

Materials scienceMulti-mode optical fiberPhysics and Astronomy (miscellaneous)business.industryRelative intensity noiseShot noisePhysics::OpticsOptical powerlow frequency noiseDistributed Bragg reflectorNoise (electronics)VCSELOpticsNoise generatorOptoelectronicsFlicker noisebusinessInstrumentationcoherence function
researchProduct

DC and 1/f noise characterization of cryogenically cooled pseudomorphic HEMT's

2002

Pseudomorphic (AlGaAs/InGaAs/GaAs) HEMT's have exhibited the best noise performance over the entire LF-to-microwave frequency range if compared to MESFET's and conventional GaAs HEMT's, due to either a reduced flicker noise, a lower G/R contribution and a smaller high-field diffusion noise. We have recently investigated the microwave (up to 18 GHz) noise properties of packaged pseudomorphic HEMT's from 290 K down to cryogenic temperature values. The current experimental work is aimed at extending such analysis to the LF noise range and at low temperatures. Cryogenic noise spectra (1 Hz to 100 KHz) and DC characteristics have therefore been recorded and the relevant observations on the devic…

Materials sciencebusiness.industryNoise reductionAstrophysics::Instrumentation and Methods for AstrophysicsGeneral Physics and AstronomyHigh-electron-mobility transistorNoise figureGallium arsenideCondensed Matter::Materials Sciencechemistry.chemical_compoundGeneration–recombination noisechemistryOptoelectronicsFlicker noiseMESFETbusinessNoise (radio)
researchProduct

Ultra-Low Noise Multiwalled Carbon Nanotube Transistors

2013

We report an experimental noise study of intermediate sized quasi ballistic semiconducting multiwalled carbon nanotube (IS-MWCNT) devices. The noise is two orders of magnitude lower than in singlewalled nanotubes (SWCNTs) and has no length dependence within the studied range. In these channel limited devices with small or negligible Schottky barriers the noise is shown to originate from the intrinsic potential fluctuations of charge traps in the gate dielectric. The gate dependence of normalized noise can be explained better using ballistic the charge noise model rather than diffusive McWhorter’s model. The results indicate that the noise properties of IS-MWCNTs are closer to SWCNTs than th…

NanotubeMaterials scienceta114Condensed Matter - Mesoscale and Nanoscale Physicsbusiness.industryTransistorGate dielectricFOS: Physical sciencesSchottky diodeNanotechnologyGeneral ChemistryCondensed Matter::Mesoscopic Systems and Quantum Hall Effectlaw.inventionCondensed Matter::Materials SciencelawMesoscale and Nanoscale Physics (cond-mat.mes-hall)OptoelectronicsGeneral Materials ScienceFlicker noisebusinessNanoscopic scaleOrder of magnitudeNoise (radio)
researchProduct

Langevin Approach to Understand the Noise of Microwave Transistors

2004

A Langevin approach to understand the noise of microwave devices is presented. The device is represented by its equivalent circuit with the internal noise sources included as stochastic processes. From the circuit network analysis, a stochastic integral equation for the output voltage is derived and from its power spectrum the noise figure as a function of the operating frequency is obtained. The theoretical results have been compared with experimental data obtained by the characterization of an HEMT transistor series (NE20283A, by NEC) from 6 to 18 GHz at a low noise bias point. The reported procedure exhibits good accuracy, within the typical uncertainty range of any experimental determin…

Noise temperatureCondensed Matter - Materials ScienceStatistical Mechanics (cond-mat.stat-mech)General MathematicsGeneral Physics and AstronomyMaterials Science (cond-mat.mtrl-sci)FOS: Physical sciencesY-factorNoise figureNoise (electronics)symbols.namesakeNoise generatorGaussian noiseElectronic engineeringsymbolsEconometricsEffective input noise temperatureFlicker noiseCondensed Matter - Statistical MechanicsMathematics
researchProduct

Advanced PSA Bipolar Transistors for Wireless Applications: Measurements of Scattering Parameters and Noise Figure

1994

A complete investigation on the performance of a series of double polysilicon self-aligned (PSA) bipolar transistors in terms of scattering parameters and noise figure is here reported. The devices have been characterized over the 1-4 GHz frequency range in several bias conditions to the aim of assessing the optimum bias values for the best trade-off between noise and gain performance. This is the first part of an extensive investigation currently performed on 5 families of PSA devices having different emitter configuration and size which have been manufactured by SGS-Thomson to undergo a comparative analysis on the global transistor performance.

Noise temperatureEngineeringNoise generatorNoise measurementNoise-figure meterbusiness.industryElectronic engineeringFlicker noiseY-factorNoise figurebusinessLow-noise amplifier44th ARFTG Conference Digest
researchProduct