Search results for "Flume"
showing 10 items of 85 documents
Investigating the Performance of Enhanced Permeable Groins in Series
2020
The enhanced permeable groin is a novel eco-friendly and cost-effective technique for bank protection and restoration of meander bends. The behavior of bed deformations due to the distance between the structures has to be studied to design enhanced permeable groins in series properly. In this study, scour morphologies around enhanced permeable groins in series, characterized by four different distances and located in a 180°
Velocity and turbulence measurements: uncertainty in the application of the Image-based technique
2018
This work focuses on the application of image-based technique to estimate velocity and turbulent flow characteristics. In particular, in the present work digital imaging technique is used for performing surface velocity measurements of hyper-concentrated flows. The analysis is conducted with the aid of data collected in a scale laboratory flume constructed at the Hydraulic laboratory of the Department of Civil, Environmental, Aerospatial and of Materials Engineering (DICAM) – University of Palermo (Italy). In the present paper a brief summary of results obtained in previous works on the flow velocity estimation error and uncertainty related to the acquisition procedure is reported.
Dissipative scaling of step-pool features
2021
Abstract This paper focuses on the dissipative similarity of step-pool units at rill, flume and stream scale. This investigation is carried out using recent advances in open channel flow resistance, applications of close-range photogrammetry to rill erosion, available published data on step-pool features in flumes and streams and a new dataset of measurements in fixed bed step-pool rills. A theoretically-based equation for calculating the Darcy-Weisbach friction factor obtained by integration of a power velocity profile is presented. The scale factor Γ of this power velocity profile, which is included in the flow resistance equation, was previously calibrated (Eq. 10) for mobile bed rills w…
Bank Erosion and Secondary Circulation in a Meandering Laboratory Flume
2014
Abstract This paper reports peculiar results of experimental investigation on the secondary circulation motion of flow along a meander wave. Experiments were conducted in a large amplitude meandering laboratory channel for two values of the width-to-depth ratio. Here attention is focalized on how secondary motion affects the bank shear stress distribution, influencing the stability of the outer bank. The analysis essentially highlights that, especially for small width-to-depth ratio, as the channel curvature increases, besides the classical central-region secondary circulation cell a counter-rotating circulation cell forms in the outer-bank region. Such counter-rotating circulation cell all…
Random wave run-up with a physically-based Lagrangian shoreline model
2014
Abstract In the present paper the run-up of random waves was calculated by means of a numerical method. In situ measurements based on a video imaging technique have been used for the validation of the present numerical model. The on-site run-up measurements have been carried out at Lido Signorino beach, near Marsala, Italy,along a transect, normal to the shore. A video camera and a linear array of rods have been used to obtain field data. Numerical simulations with a 1DH Boussinesq-type of model for breaking waves which takes into account the wave run-up by means of a Lagrangian shoreline model have been carried out. In such simulations random waves of given spectrum have been propagated in…
Field run-up measurements: Calibration of a physically based lagrangian shoreline model
2012
In the present contribution a measurement technique based on video imaging has been selected for the assessment of the maximum run-up. Such measurements have been used for the calibration of a numerical model and of an empirical formulation. The on-site run-up measurements have been carried out at “Lido Signorino” beach, near Marsala, Italy. The positions of the swash have been localized on a transect, normal to the shore, constituted by stakes placed at 0.5 m intervals each other. The video camera was placed orthogonally to the line of the stakes. For the numerical simulations a 1DH Boussinesq-type of model for breaking waves has been applied which takes into account the wave run-up by a L…
Development of an improved method for trace analysis of quinolones in eggs of laying hens and wildlife species using molecularly imprinted polymers.
2012
A sensitive, selective, and efficient method was developed for simultaneous determination of 11 fluoroquinolones (FQs), ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, flumequine, marbofloxacin, norfloxacin, ofloxacin, oxolinic acid, pipemidic acid, and sarafloxacin, in eggs by molecularly imprinted polymer (MIP) and column liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Samples were diluted with 50 mM sodium dihydrogen phosphate at pH 7.4, followed by purification with a commercial MIP (SupelMIP SPE-Fluoroquinolones). Recoveries for the 11 quinolones were in the range of 90-106% with intra- and interday relative standard deviation ranging from …
Effects of pH and the presence of micelles on the resolution of diuretics by reversed-phase liquid chromatography
2004
A comparative study on the performance of two RPLC modes on the separation of 18 diuretics with diverse acid-base behaviour (acetazolamide, althiazide, amiloride, bendroflumethiazide, benzthiazide, bumetanide, canrenoic acid, chlorothiazide, chlorthalidone, ethacrynic acid, furosemide, hydrochlorothiazide, piretanide, probenecid, spironolactone, triamterene, trichloromethiazide and xipamide) was carried out. A conventional octadecylsilane column and acidic acetonitrile-water mobile phases, in the absence and presence of micelles of the anionic surfactant sodium dodecyl sulphate (SDS), were used. The effects of pH and the modifiers acetonitrile and SDS on peak asymmetry, efficiency, selectiv…
Chromatographic monitoring of diuretics in urine samples using a sodium dodecyl sulphate—propanol micellar eluent
1994
Abstract The effect of a varying pH, in the range 3−7, on the retention of several diuretics eluted with a sodium dodecyl sulphate (SDS) micellar mobile phase and with UV detection was studied. Significant changes in the capacity factors ( K′ of the diuretics bumetanide, ethacrynic acid, furosemide, probenecid and xipamide were observed. The protonation constants of these compounds were calculated from the k′ data. A study was also performed to select the optimum composition of the mobile phase (pH, concentration of SDS and nature and concentration of alcohol) for the separation of the above diuretics and the diuretics amiloride, bendroflumethiazide, chlorthalidone, hydrochlorothiazide, spi…
Chromatographic determination of diuretics in urine samples using hybrid micellar mobile phases with fluorimetric detection
1998
Abstract A rapid and simple chromatographic procedure, that uses hybrid micellar mobile phases of sodium dodecyl sulphate (SDS), propanol and phosphate buffer at pH 3, and fluorimetric detection ( λ exc =270 nm, λ em =430 nm), is reported for the determination of mixtures of seven diuretics of diverse efficacy (amiloride, bendroflumethiazide, bumetanide, furosemide, hydroflumethiazide, piretanide and triamterene), in urine samples. The application of a sequential optimization procedure for the resolution of the mixtures of the diuretics was problematic. However, their separation was achieved through the use of an interpretive optimization procedure based on the accurate description of the r…