Search results for "Fluorescence"
showing 10 items of 2463 documents
Time-Gated Raman Spectroscopy for Quantitative Determination of Solid-State Forms of Fluorescent Pharmaceuticals
2018
Raman spectroscopy is widely used for quantitative pharmaceutical analysis, but a common obstacle to its use is sample fluorescence masking the Raman signal. Time-gating provides an instrument-based method for rejecting fluorescence through temporal resolution of the spectral signal and allows Raman spectra of fluorescent materials to be obtained. An additional practical advantage is that analysis is possible in ambient lighting. This study assesses the efficacy of time-gated Raman spectroscopy for the quantitative measurement of fluorescent pharmaceuticals. Time-gated Raman spectroscopy with a 128 X (2) X 4 CMOS SPAD detector was applied for quantitative analysis of ternary mixtures of sol…
Do fluorescence and transient absorption probe the same intramolecular charge transfer state of 4-(dimethylamino)benzonitrile?
2009
International audience; We present here the results of time-resolved absorption and emission experiments for 4-(dimethylamino)benzonitrile in solution, which suggest that the fluorescent intramolecular charge transfer (ICT) state may differ from the twisted ICT (TICT) state observed in transient absorption.
Heterogeneity of aggregates in the fibrillation mechanisms of proteins probed by time resolved fluorescence
2010
Under appropriate conditions almost all proteins are able to aggregate to form long, well-ordered and beta-sheet rich arrays known as amyloid fibrils. The formation of such structures involves complex intra and intermolecular interactions modulated by the structure and dynamics of the native protein, and by the physico-chemical properties of the solvent. Multiple interactions and cross-feedback during the aggregation pathway cause different ultimate aggregates’ morphologies and the possible simultaneous occurrence of multiple species. The structural definition of such assemblies is complicated by the polymorphism of the amyloid fibrils. Aim of this study is to inquire on the different natur…
Ultrafast excitation dynamics of low energy pigments in reconstituted peripheral light-harvesting complexes of photosystem I
2000
AbstractUltrafast dynamics of a reconstituted Lhca4 subunit from the peripheral LHCI-730 antenna of photosystem I of higher plants were probed by femtosecond absorption spectroscopy at 77 K. Intramonomeric energy transfer from chlorophyll (Chl) b to Chl a and energy equilibration between Chl a molecules observed on the subpicosecond time scale are largely similar to subpicosecond energy equilibration processes within LHCII monomers. However, a 5 ps equilibration process in Lhca4 involves unique low energy Chls in LHCI absorbing at 705 nm. These pigments localize the excitation both in the Lhca4 subunit and in LHCI-730 heterodimers. An additional 30–50 ps equilibration process involving red …
Selective labelling of melittin with a fluorescent dansylcadaverine probe using guinea-pig liver transglutaminase
1991
Abstract Melittin, a C-terminal peptide, incorporated the fluorescent probe monodansylcadaverine (DNC) when catalysed by guinea-pig liver transglutaminase and Ca2+, as determined by thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). A 1:1 adduct DNC-melittin was identified in which a single glutamine residue out of two, i.e. Gln25, acts as acyl donor. Incubation of melittin with transglutaminase in the absence of DNC originated high molecular mass complexes indicative that the peptide lysine residue can act as an acyl acceptor. The DNC-melittin was about 3 times more active in the lysis of red cell membranes than native melittin. Fluorescence study of the lab…
Binding, Interaction, and Organization of Proteins with Lipid Model Membranes
1991
Model membrane systems are used to investigate protein recognition and binding at interfaces. Fluorescence microscopy results are presented for interactions of the proteins, phospholipase A2 and antifluorescyl IgG, at lipid monolayer interfaces. Total internal reflection fluorescence measurements are used to quantify albumin and IgG adsorption to supported lipid monolayers.
Comparison of total-reflection X-ray fluorescence, static and portable energy dispersive X-ray fluorescence spectrometers for art and archeometry stu…
2004
Abstract In this paper, a Total-reflection X-ray Fluorescence (TXRF), a static and a portable Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers are described. Both the equipments and the techniques employed in the field of the art and archeometry are compared. Some applications in this area are presented as well. The aim of the work is to know which spectrometer is the best suited depending on the work of art and the problem treated. The conclusion reached from the experience is that the portable EDXRF spectrometer is advisable to make “in situ” and online analysis in a multidisciplinary environment, the static EDXRF equipment is good to perform analysis on paper and metal pieces a…
Theoretical and experimental analysis of photonic structures for fluorescent concentrators with increased efficiencies
2008
In this study we present a theoretical and experimental analy- sis of the application of photonic band stop filters on top of photovoltaic fluorescent concentrators in order to increase the photon collection efficiency. The light guiding effect of the fluorescent concentrator relies on total internal reflection. The escape cone of total internal reflection is their major loss mechanism. Our ray tracing simulation allows to calculate the beneficial effect of photonic band stop reflection filters, which reduce these losses, and to simulate the angular distribu- tion of the light trapped in the concentrator. We present simula- tions of the optical properties of 1D and 3D photonic structures an…
Chemical fingerprint of outdoor PM2.5 in Malta
2015
Intro: RESPIRA (EU Funded - Italia-Malta 07-13) indicated that living in Malta is a risk factor for asthma. Aim: To determine the chemical profile of PM2.5 in Malta, and compare with reference values. Methods: Using FAI pumps at 10l/min/48hr, samples were collected on Teflon and Quartz filters from 6 schools and 46 homes in Malta. Total ICP-MS measurement (Residual+extracted), X ray Fluorescence, and thermo-optical methods(TO) were used for analysis by CNR in Rome. Aeroqual IQM60 counters were used for total PM2.5 mass. All data in ng/m3, Mean, (1st to 3rd quartile) of all 48 hour measurements.
Differences of stabilized organic carbon fractions and microbiological activity along Mediterranean Vertisols and Alfisols profiles
2010
This study examined the chemical and structural properties of humic substances and microbiological activity in order to verify differences in carbon dynamics along soil profiles in two Vertisols (Typic Haploxerert and Xeric Epiaquert) and two Alfisols (Mollic Haploxeralf and Ultic Haploxeralf) developed under Mediterranean climate in Italy. Humification parameters, thermal methods, including differential scanning calorimetry (DSC) and thermogravimetry (TG), together with Fourier transform infrared (FT-IR) and fluorescence spectroscopies were used to characterize humic acids (HA). Microbiological activity of soils was assessed by basal respiration, metabolic quotient (qCO2) and Cmic:Corg rat…