Search results for "Fluorescence"

showing 10 items of 2463 documents

3-Formyl-BODIPY Phenylhydrazone as a Chromo-Fluorogenic Probe for Selective Detection of NO2 (g)

2016

Anew colorimetric and fluorogenic probe,based on a3-formyl boron dipyrromethene (BODIPY)phe-nylhydrazone, for the sensitive and selectivedetectionNO2(g) has been prepared. The probeinsolution experi-ences aremarkablehypsochromic shift of its absorptionand fluorescence emission bands in the presence gaseousNO2(g), leading to limits of detectio noffew ppb. Theprobe also works in the solid phase, adsorbed on filterpaper strips, or chemically immobilized on the surfaceofsilica nanop articles, with limitsofdetection to the nakedeye of about 0.5 ppm.

Detection limitChemodosimeterFilter paper010405 organic chemistryChemistryOrganic ChemistryPhenylhydrazoneGeneral Chemistry010402 general chemistryPhotochemistry01 natural sciencesFluorescenceCatalysis0104 chemical sciencesNO2 detectionchemistry.chemical_compoundAdsorptionBODIPYChromo-fluorogenic probesHypsochromic shiftNaked eyeAbsorption (chemistry)BODIPY
researchProduct

Interaction of diazepam with surfactants. Spectrophotometric and spectrofluorometric study

1986

Abstract The interaction of diazepam with non-ionic, anionic and cationic surfactants has been studied spectrophotometrically and fluorometrically. It has been verified that the absorption spectrum of diazepam is not modified in micellar medium. However, a dramatic five-fold increase in fluorescence sensitivity is observed in the presence of sodium lauryl sulphate (SDS). The experimental conditions, temperature, pH and surfactant concentration have been optimized to improve the fluorometric determination of diazepam and a detection limit of 0,04 ppmhas been obtained.

Detection limitChromatographyAbsorption spectroscopyChemistryOrganic ChemistrySodium lauryl sulphateCationic polymerizationFluorescenceAnalytical ChemistryInorganic ChemistryPulmonary surfactantmedicineDiazepamSpectroscopymedicine.drugJournal of Molecular Structure
researchProduct

Evaluation of C18 adsorbent cartridges for sampling and derivatization of primary amines in air

2004

Abstract The sampling efficiency of C18 solid-phase extraction cartridges was investigated for methylamine, ethylamine, propylamine, butylamine and pentylamine, in air. Determination of these analytes was based on derivatization with o-phthaldialdehyde–N-acetylcysteine (OPA–NAC) on the solid support and fluorescence detection at λexcitation=330 nm and λemission=440 nm of the eluted derivatives. The calibration model derived from aqueous standards was statistically comparable with the calibration model for air standards. Aqueous amines can be used as standards. The method was useful for calculating short-term exposure limits (STEL). A sampling time of 15 min at 30 ml min−1 was employed. Good…

Detection limitChromatographyButylamineFluorescence spectrometryAnalytical chemistryPropylamineBiochemistryAnalytical ChemistryStandard curvechemistry.chemical_compoundchemistryEnvironmental ChemistrySolid phase extractionPentylamineDerivatizationSpectroscopyAnalytica Chimica Acta
researchProduct

Quantification of nortriptyline in plasma by HPLC and fluorescence detection

2009

Abstract A simple, sensitive and specific high-performance liquid chromatography method has been developed for the determination of nortriptyline (NT) in plasma samples. The assay involved derivatization with 9H-fluoren-9-ylmethyl chloroformate (Fmoc-Cl) and isocratic reversed-phase (C 18 ) chromatography with fluorescence detection. The developed method required only 100 μl of plasma sample, deproteinized and derivatized in one step. Calibration curves were lineal over the concentration range of 5–5000 ng/ml. The derivatization reaction was performed at room temperature in 20 min and the obtained NT derivative was stable for at least 48 h at room temperature. The within-day and between-day…

Detection limitChromatographyCalibration curveClinical BiochemistryNortriptylineCell BiologyGeneral MedicineDerivativeChloroformateBiochemistryHigh-performance liquid chromatographyFluorescenceAntidepressive AgentsRatsAnalytical Chemistrychemistry.chemical_compoundchemistryLimit of DetectionmedicineAnimalsHumansNortriptylineDerivatizationChromatography High Pressure Liquidmedicine.drugJournal of Chromatography B
researchProduct

Micellar enhanced fluorimetric determination of carbendazim in natural waters

1994

Abstract A micellar enhanced flow-injection fluorimetric method was developed for the determination of carbendazim in natural water samples. The method is based on the direct injection of 500 μ1 of water into a three-channel flow manifold in which the samples are merged with a buffer solution and subsequently with a surfactant solution. Two alternative procedures were used: one based on the use of sodium dodecyl sulphate micelles in 0.1 M HCl, which permits a 2.6-fold enhancement of the sensitivity found in the absence of micelles to be obtained, and the other based on the use of cetyltrimethylammonium bromide in 0.1 M NaOH, which provides a 11.6-fold enhancement of sensitivity and a limit …

Detection limitChromatographyCarbendazimSodiumFluorescence spectrometrychemistry.chemical_elementBuffer solutionBiochemistryMicelleAnalytical Chemistrychemistry.chemical_compoundchemistryPulmonary surfactantBromideEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Spectrofluorimetric Determination of Iproniazid and Isoniazid in a FIA System Provided with a Solid-Phase Reactor

1998

Abstract A FIA assembly is proposed for the fluorimetric determination of iproniazid and isoniazid. The oxidation of both drugs is carried out by H2O2. The excess of reagent is destroyed and removed from the flow-injection manifold by means of a metallic copper reactor which acts as catalyst in the decomposition of H2O2 and a home made debubbler. The calibration graphs were linear up to 14 μg ml−1 and 10 μg ml−1 (n=6) for iproniazid and isoniazid, respectively, with limits of detection of 0.008 μg ml−1 and 0.005 μg ml−1. The sample throughput was 24 h−1 for both drugs. The influence of foreign compounds was studied and the procedure was applied to determination of iproniazid and isoniazid i…

Detection limitChromatographyChemistryBiochemistry (medical)Clinical BiochemistryIsoniazidFluorescence spectrometryBiochemistryDosage formAnalytical ChemistryIproniazidReagentPhase (matter)ElectrochemistrymedicineQuantitative analysis (chemistry)Spectroscopymedicine.drugAnalytical Letters
researchProduct

A solid-phase extraction and size-exclusion liquid chromatographic method for polyethylene glycol 25 p-aminobenzoic acid determination in urine: Vali…

2007

No previous publications about percutaneous absorption of polyethylene glycol 25 p-aminobenzoic acid (PEG-25 PABA) have been found in the literature and the expected levels to be found in human urine after sunscreens use are unknown. The method proposed here is suitable to determine PEG-25 PABA in the urine of sunscreens users in order to carry out studies on body accumulation/excretion. It is based on solid-phase extraction (SPE) with size-exclusion liquid chromatography determination. Solid-phase extraction allows the analyte to be retained and subsequently eluted for a clean-up, using a silica-based cartridge. The size-exclusion liquid chromatography of the eluted allows the rest of matr…

Detection limitChromatographyChemistryElutionExtraction (chemistry)Fluorescence spectrometryReproducibility of ResultsUrineBiochemistryPolyethylene GlycolsAnalytical ChemistryMatrix (chemical analysis)ExcretionSpectrometry FluorescenceChromatography GelHumansEnvironmental ChemistrySolid phase extraction4-Aminobenzoic AcidSunscreening AgentsSpectroscopyAnalytica Chimica Acta
researchProduct

High performance liquid chromatography—atomic fluorescence spectrometric determination of arsenic species in beer samples

2003

Abstract A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation—atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH 2 PO 4 /K 2 HPO 4 as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 …

Detection limitChromatographyChemistryHydrideElutionAnalytical chemistryFluorescence spectrometrychemistry.chemical_elementHydrochloric acidBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySeparation processchemistry.chemical_compoundEnvironmental ChemistrySpectroscopyArsenicAnalytica Chimica Acta
researchProduct

Determination of total arsenic in soft drinks by hydride generation atomic fluorescence spectrometry

2007

Abstract A highly sensitive and simple method has been developed for the determination of total arsenic, by continuous hydride generation and atomic fluorescence spectrometry (HGAFS), in refreshing drink samples as colas, teas and fruit juices. Samples were mixed with concentrated HCl and KI to obtain final concentrations of 2 mol l−1 and 1%, respectively. These solutions were aspirated and merged with a reducing NaBH4 3% (m/v) solution, with sample and NaBH4 flow rates of 12.5 and 1.5 ml min−1, respectively. The hydride generated in a 170 cm reaction coil was transported to the detector with an Ar flow of 400 ml min−1. The recovery values of added concentrations, from 0.1 to 0.9 ng ml−1, o…

Detection limitChromatographyChemistryHydrideFluorescence spectrometryAnalytical chemistrychemistry.chemical_elementGeneral MedicineAtomic fluorescence spectrometryAnalytical ChemistryHighly sensitiveVolumetric flow rateAshingArsenicFood ScienceFood Chemistry
researchProduct

High-performance liquid chromatographic determination of tocopherols in infant formulas

2002

A method for the simultaneous determination of alpha-tocopherol acetate and alpha-, delta-, and gamma-tocopherols by normal-phase high-performance liquid chromatography (HPLC) with a fluorescent detector in infant formula is proposed. The values obtained in the determination of the analytical parameters: linearity, precision, limit of detection and accuracy (analysis of a standard reference material, SRM 1846), confirm the quality of the method. The proposed method is useful for the determination of alpha-, delta-, and gamma-tocopherols and alpha-tocopherol acetate in infant formulas at a low cost and in a total time of 2 h.

Detection limitChromatographyChemistryVitamine eOrganic ChemistryDetectorAnalytical chemistryInfantReproducibility of ResultsTocopherolsfood and beveragesLinearityGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySpectrometry FluorescenceHumansInfant FoodQuantitative analysis (chemistry)Chromatography High Pressure LiquidAnalysis methodJournal of Chromatography A
researchProduct