Search results for "Fluorescence"
showing 10 items of 2463 documents
Integrated three-dimensional models for noninvasive monitoring and valorization of the Morgantina silver treasure (Sicily)
2016
The Morgantina silver treasure belonging to the Archaeological Museum of Aidone (Sicily) was involved in a three-dimensional (3-D) survey and diagnostics campaign for monitoring the collection over time in anticipation of their temporary transfer to the Metropolitan Museum of Art in New York for a period of 4 years. Using a multidisciplinary approach, a scientific and methodological protocol based on noninvasive techniques to achieve a complete and integrated knowledge of the precious items and their conservation state, as well as to increase their valorization, has been developed. All acquired data, i.e., 3-D models, ultraviolet fluorescence, x-ray images, and chemical information, will be…
Treatment of a submerged anaerobic membrane bioreactor (SAnMBR) effluent by an activated sludge system: the role of sulphide and thiosulphate in the …
2014
This work studies the use of a well-known and spread activated sludge system (UCT configuration) to treat the effluent of a submerged anaerobic membrane bioreactor (SAnMBR) treating domestic waste-water. Ammonia, phosphate, dissolved methane and sulphide concentrations in the SAnMBR effluent were around 55 mg NH4-N L-1, 7 mg PO4-P L-1, 30 mg non-methane biodegradable COD L-1, and 105 mg S2- L-1 respectively. The results showed a nitrification inhibition caused by the presence of sulphur compounds at any of the solids retention time (SRT) studied (15,20 and 25 days). This inhibition could be overcome increasing the hydraulic retention time (HRT) from 13 to 26 h. Among the sulphur compounds, …
Monitoring WWTP performance using size-exclusion chromatography with simultaneous UV and fluorescence detection to track recalcitrant wastewater frac…
2018
Abstract A trial monitoring of a typical full-scale municipal WWTP in Central Finland was aimed to explore applicability of high performance liquid chromatography – size exclusion chromatography (HPSEC) with simultaneous UV and fluorescence detection as a tool for advanced routine monitoring of wastewater treatment. High, intermediate, and low molecular weight (MW) fractions of untreated wastewater (influent) and treated wastewater (secondary effluent) were characterized in terms of UV absorbance at 254 nm (UVA254) and specific fluorescence representing tyrosine-like, tryptophan-like, and humic/fulvic-like compounds. The activated sludge treatment removed 97 ± 1% of BOD, 93 ± 2% of COD, 71 …
Photo-induced fluorescence of magnesium derivatives of tetracycline antibiotics in wastewater samples
2009
Abstract An analytical strategy, for the determination of tetracyclines (TCs), based on a HPLC system coupled with a photo-reactor followed by post-column derivatization was developed. Higher fluorescence emission after coupling the resulting photo-fragments with magnesium ions was observed for the determination of minocycline (MC), epitetracycline (ETC), tetracycline (TC) and doxycycline (DC). The manifold included a HPLC system with a photo-reactor (PTFE tubing helically coiled around a low-pressure mercury lamp), a mixing T-piece and a fluorescence detector. The derivatization reagent was delivered at 0.5 mL min −1 by a pump. After HPLC separation using a gradient system with a mobile ph…
Reliable method for assessing the COD mass balance of a submerged anaerobic membrane bioreactor (SAMBR) treating sulphate-rich municipal wastewater
2012
The anaerobic treatment of sulphate-rich wastewater causes sulphate reducing bacteria (SRB) and methanogenic archaea (MA) to compete for the available substrate. The outcome is lower methane yield coefficient and, therefore, a reduction in the energy recovery potential of the anaerobic treatment. Moreover, in order to assess the overall chemical oxygen demand (COD) balance, it is necessary to determine how much dissolved CH4 is lost in the effluent. The aim of this study is to develop a detailed and reliable method for assessing the COD mass balance and, thereby, to establish a more precise methane yield coefficient for anaerobic systems treating sulphate-rich wastewaters. A submerged anaer…
Interactions between calcium precipitation and the polyphosphate-accumulating bacteria metabolism
2007
A sequencing batch reactor that is operated for biological phosphorus removal has been operated under different influent calcium concentrations to study the precipitation process and the possible effects of phosphorus precipitation in the biological phosphorus removal process. Four experiments were carried out under different influent calcium concentrations ranging from 10 to 90 g Ca m(-3). The experimental results and the equilibrium study, which are based on the saturation index calculation, confirm that the process controlling the calcium behaviour is the calcium phosphate precipitation. This precipitation takes place at two stages: initially, precipitation of the amorphous calcium phosp…
Superoxide-driven autocatalytic dark production of hydroxyl radicals in the presence of complexes of natural dissolved organic matter and iron.
2019
Abstract We introduced superoxide as potassium superoxide (KO2) to artificial lake water containing dissolved organic matter (DOM) without or with introduced ferric iron complexes (DOM-Fe(III)), and monitored the production rate of hydroxyl radicals as well as changes in the absorption and fluorescence properties of DOM. The introduction of KO2 decreased the absorption by DOM but increased the spectral slope coefficient of DOM more with complexed ferric Fe than without it. The introduction of KO2 increased the fluorescence of humic-like components in DOM without introduced ferric Fe but resulted in the loss of fluorescence in DOM with introduced ferric Fe. A single introduction of 13 μmol L…
Vertical Distribution and Speciation of Trace Metals in Weathering Flotation Residues of a Zinc/Lead Sulfide Mine
2007
Sulfide-bearing mine tailings are a serious environmental problem around the world. In this study, the vertical distribution and speciation of Zn and Pb in the fine-grained flotation residues of a former sulfide ore mine in Germany were investigated to assess the inorganic weathering processes that effect the environmental risk arising from this site. Total metal contents were determined by X-ray fluorescence spectroscopy (XRF). Mobilizable fractions of Zn, Pb, Fe, and Mn were quantified by sequential chemical extractions (SCE). Furthermore, the speciation of Zn was analyzed by Zn K-edge extended X-ray absorption fine structure spectroscopy (EXAFS) to identify the residual Zn species. The v…
Internal dynamics and energy transfer in dansylated POPAM dendrimers and their eosin complexes.
2010
Internal dynamics of dansylated poly(propyleneamine) dendrimers (POPAM, G1-G4) in solution and excitation energy transfer from dansyls to eosin in POPAM-eosin complexes have been studied by time-resolved fluorescence spectroscopy and molecular dynamics (MD) simulations. Combining the results from fluorescence anisotropy and the MD simulation studies suggests three time domains for the internal dynamics of the G3 and G4 generations, about 60 ps for motions of the outer-sphere dansyls, 500-1000 ps for restricted motions of back-folded dansyls, and 1500-2600 ps for the overall rotation. For the smaller generations, the contribution from the restricted motions was not entirely evident. Eosin bi…
Derivatization of ephedrine with o-phthaldialdehyde for liquid chromatography after treatment with sodium hypochlorite.
2000
The usefulness of the reaction with NaClO followed by derivatization with o-phthaldialdehyde (OPA) and N-acetyl-L-cysteine (NAC) has been investigated for the chromatographic analysis of ephedrine. The influence of parameters affecting the two-stage reaction has been evaluated, including concentration of NaClO, time of reaction, temperature and pH. On the basis of these studies, conditions for the pre-column and (automated) post-column determination of ephedrine are presented. The described conditions have been applied to the measurement of ephedrine in the concentration intervals 0.2-20.0 microg/ml and 2.0-50.0 microg/ml for the pre-column and post-column methods, respectively. The possibi…