Search results for "Fourier Transform Infrared"
showing 10 items of 598 documents
ATR-Spin: an open-source 3D printed device for direct cytocentrifugation onto attenuated total reflectance crystals.
2021
Infrared Spectroscopy (IR) enables the direct and rapid characterization of cells at the molecular level. Achieving a rapid and consistent cell preparation is critical for the development of Point-of-Care diagnostics for cell analysis. Here we introduce an open-source, 3D printed device for integrating the isolation, preconcentration, and measurement of attenuated total reflectance IR spectra of cells from biofluids. The tool comprises a disposable card for cytocentrifugation, equipped with magnets, which allows reproducible integration into the pathlength of the IR spectrophotometer. Preliminary results using cell media containing A459 cells indicate that this system enables a qualitative …
FTIR quantitative analysis of calcium carbonate (calcite) and silica (quartz) mixtures using the constant ratio method. Application to geological sam…
2002
A methodology for quantifying calcium carbonate (875 and 712 cm(-1)) and silica (798 and 779 cm(-1)) by FTIR spectroscopy applying the constant ratio method is proposed. The studied method is applied for quantitative analysis of calcite and quartz in geological samples. The suggested method uses potassium ferricyanide (2115 cm(-1)) as standard and samples are prepared as potassium bromide pellets, with statistically satisfactory results (relative standard deviation less than 5%). The influence of particle size (pulverised samples) on the accuracy of the results found by FTIR spectroscopy applying the constant ratio method has been studied. The granulometric study suggests that the homogenei…
FTIR spectroscopy studies of high pressure-induced changes in pork macromolecular structure
2019
Abstract High pressure processing (HPP) allows to extend the shelf life of meat and meat products by pressurization of microorganisms. At the same time, HPP can induce changes of the protein structure. Vacuum-packed pork chops were HPP-treated at 300, 600 MPa for 1 or 15 min. Samples of raw, cooked and HPP-treated meat muscles and juice were analysed to evaluate the structure of macromolecules. HPP caused visible discolouration of pork chops; hence, the colour of pork meat surface was tested. The lightness (colour component L*) was directly proportional to the applied pressure, probably due to the increased protein denaturation by high pressure. Pork meat muscle and juice samples were analy…
Lanthanide–saccharide chemistry: synthesis and characterisation of Ce(III)–saccharide complexes
2000
A series of nine Ce(III) complexes has been synthesised with seven different monosaccharides (D-glucose, D-fructose, D-galactose, D-mannose, L-sorbose, D-ribose and D-xylose) and two different disaccharides (D-maltose and L-lactose), and these have been characterised with various analytical, spectral, magnetic and electrochemical techniques. The NMR studies have highlighted some interesting features about the metal-ion-binding pattern of the saccharides. Some additional coordination has been proposed along with the chelating groups in the saccharide molecules, based on the shifts in 13C NMR spectra. On the other hand, solution absorption studies and solid-state magnetic susceptibilities hav…
Study of water adsorption and capillary bridge formation for SiO(2) nanoparticle layers by means of a combined in situ FT-IR reflection spectroscopy …
2014
Water adsorption and capillary bridge formation within a layer of SiO2-nanoparticles were studied in situ by means of a combination of quartz crystal microbalance (QCM-D) with dissipation analysis and Fourier transformation infrared reflection absorption spectroscopy (FT-IRRAS). FT-IR data were employed to distinguish the “ice-like” and “liquid-like” contributions and to support the analysis of the QCM-D data concerning mass change and dissipation. Combined measurements show that for SiO2-nanoparticles with a diameter of about 250 nm, the formation of two adsorbed monolayers of water as well as bulk water leads to a rather linear increase in the dissipation for relative humidity values of u…
Irradiation effects on the OH-related infrared absorption band in synthetic wet silica.
2007
The effects of b-irradiation on the OH-related infrared (IR) absorption band in synthetic wet silica samples have been investigated by Fourier transform infrared spectroscopy. Depending on the accumulated doses, b-irradiation affects different zones of the IR composite band at about 3670 cm 1 , assigned to the OH stretching modes of silanol groups. These modifications are independent of the original OH content. The results are discussed considering possible radiation-induced changes of the silanol bonding configuration and of the glass network. These are monitored by revealing the IR band a 2260 cm 1 , which is related to the distribution of Si–O–Si bond angle. We have identified the existence of…
Iodine−Benzene Complex as a Candidate for a Real-Time Control of a Bimolecular Reaction. Spectroscopic Studies of the Properties of the 1:1 Complex I…
2009
The properties of the 1:1 iodine-benzene complex isolated in a solid Kr matrix at low temperatures have been studied using UV-vis absorption, FTIR, resonance Raman, and femtosecond coherent anti-Stokes Raman spectroscopy (fs-CARS). The use of all these techniques on similar samples provides a wide view on the spectroscopic properties of the complex and allows comparison and combination of the results from different methods. The results for the complex cover its structure, the changes in the iodine molecule's vibrational frequencies and electronic absorption spectrum upon complexation, and the dynamics of the complexed I(2) molecule on both ground and excited electronic states. In addition, …
Characterization of particle morphology of biochanin A molecularly imprinted polymers and their properties as a potential sorbent for solid-phase ext…
2014
Abstract Molecularly imprinted polymers (MIPs) with biochanin A as a template were obtained using a bulk polymerization with non-covalent imprinting approach. The polymers were prepared in acetonitrile as porogen, using ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The synthesis, with an application of 1′,1′-azobis(cyclohexanecarbonitrile) (ACHN) as an initiator, has been performed thermally. During the synthesis process the effect of different functional monomers such as methacrylic acid (MAA), acrylamide (AA) and 4-vinylpyridine (4-VP) was investigated. The application of nitrogen sorption porosimetry, scanning electron microscopy (SEM), and Fourier transform infrared spec…
Coordination properties of adenosine-5'-monophosphate and related ligands towards Me2Sn(IV)2+ in aqueous solution.
2002
Abstract The coordination of Me 2 Sn(IV) 2+ to adenosine-5′-monophosphate (AMP) and the related compounds d -ribose-5-phosphate (R5P), d -glucose-1-phosphate (G1P) and d -glucose-6-phosphate (G6P) in aqueous solution was investigated by means of potentiometric titration, and 1 H-, 31 P-NMR and Mossbauer spectroscopic methods in the pH range 2–11 ( I =0.1 M NaClO 4 , 298 K). The complex of AMP and Me 2 Sn(IV) 2+ precipitated at low pH was characterised by elemental analysis, FT-IR and Mossbauer spectroscopic methods. From a comparison of the p K values obtained in the presence and absence of metal ion and the stability constants for the different systems, the coordination of {N} is excluded,…
Noninvasive double confirmation of cocaine abuse.
2013
A double confirmation procedure, based on the combined application of Ion Mobility Spectrometry (IMS) and Infrared Spectroscopy (IR), has been developed for the noninvasive unambiguous identification of cocaine consume. The use of nasal mucus as a biological specimen for cocaine abuse confirmation has been proposed as an alternative to the use of blood and urine due to its noninvasive character and the presence of the parent compound instead of its metabolites. Sampling conditions, interferences caused by cutting agents and other substances, and limits of identification (LOI) and confirmation (LOC) have been deeply evaluated. The procedure combines the high sensitivity of the IMS to identif…