Search results for "Full width"
showing 10 items of 91 documents
Photoluminescence excited by ArF and KrF lasers and optical absorption of stishovite mono-crystal
2008
Two photoluminescence bands were found in a stishovite (silicon dioxide) mono-crystal sample under ArF (193 nm) and KrF (248 nm) excitation. The blue band is situated at 3.17 ± 0.02 eV in the case of ArF and at 3 ± 0.2 in the case of KrF. The UV band is at 4.55 ± 0.05 eV in the case of ArF and at 4.5 ± 0.05 eV in the case of KrF. The position of the UV emission band correlates with that excited by x rays. This position is 4.6 ± 0.05 eV with FWHM 0.8 ± 0.05 eV (Truhins et al 2003 Solid State Commun. 127 415). The blue band possesses slow decay kinetics with time constant 16 ± 2 µs and the UV band is fast on the level of 2 ± 0.5 ns, similarly for both lasers. Thermal quenching of both bands b…
Experimental realization of a pillared metasurface for flexural wave focusing
2021
International audience; A metasurface is an array of subwavelength units with modulated wave responses that show great potential for the control of refractive/reflective properties in compact functional devices. In this work, we propose an elastic metasurface consisting of a line of pillars with gradient heights, erected on a homogeneous plate. The change in the resonant frequencies associated with the height gradient allows us to achieve transmitted phase response covering a range of 2π, while the amplitude response remains at a relatively high level. We employ the pillared units to design a focusing metasurface and compare the properties of the focal spots through simulation and experimen…
High-energy X-ray diffraction and topography investigation of CdZnTe
2005
High-energy transmission x-ray diffraction techniques have been applied to investigate the crystal quality of CdZnTe (CZT). CdZnTe has shown excellent performance in hard x-ray and gamma detection; unfortunately, bulk nonuniformities still limit spectroscopic properties of CZT detectors. Collimated high-energy x-rays, produced by a superconducting wiggler at the National Synchrotron Light Source’s X17B1 beamline, allow for a nondestructive characterization of thick CZT samples (2–3 mm). In order to have complete information about the defect distribution and strains in the crystals, two series of experiments have been performed. First, a monochromatic 67 keV x-ray beam with the size of 300×3…
Near-intrinsic energy resolution for 30-662 keV gamma rays in a high pressure xenon electroluminescent TPC
2013
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 Xe-136 neutrino-less double beta decay (0 nu beta beta) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of similar to 1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and similar to 5% FWHM for 30 keV fluorescence xenon X-…
Stark broadening of the hydrogen Paschen ? transition at electron densities of the order of $ \mathsf {10^{15}}$ cm $ \mathsf {^{-3}}$
2003
Stark broadening measurements and calculations of the Paschen γ spectral line of hydrogen ( λ = 1.094[: MU :] m) are reported. Investigations have been performed at plasma electron densities between 1.4×10 15 cm -3 and 3.7×10 15 cm -3 . As the light source a wall-stabilized arc operated in a helium-hydrogen gas mixture at atmospheric pressure has been applied. The radiation of the plasma emitted from nearly homogeneous plasma layers in end-on direction, was measured with the use of a grating spectrometer equipped with a charge coupled device (CCD) detector. The radiance calibration was carried out against light outputs originating from a tungsten strip radiation standard. The measured FWHM …
Calibration of the width of the NI spectral line at for electron density determination
2002
Abstract The Stark broadening of a NI spectral line at 7915.42 A has been calibrated for electron density determination of low temperature plasmas. The determined simple formula based on measured FWHM is applicable in the electron density range from 3×1015 to 10 16 cm −3 .
Initial results on energy resolution of the NEXT-White detector
2018
One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q$_{\beta\beta}$.
Raman spectroscopy of synthetic, geological and biological vaterite: a Raman spectroscopic study
2009
Raman spectroscopy was used to study vaterite samples of biological, geological and synthetic origin. The Raman band positions and the full width at half-maximum (FWHM) of the lattice modes and the internal modes of the carbonate ion of all specimens show no significant differences between vaterites of different origin. With increasing Mg concentrations, synthetic vaterite samples show increasing FWHM in the region of the lattice modes and the three ν1 bands, whereas no change in luminescence was detected. In contrast, in situ measurements of vaterite areas in freshwater cultured pearls (FWCPs) by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) together with the Rama…
Wide range excitation of visible luminescence in nanosilica
2010
The visible luminescence of nanometer-sized silica particles (7 nm mean diameter) was investigated using time resolved spectroscopy. This luminescence is characterized by a wide excitation in the visible and ultraviolet range. The emission spectrum is centred at 2.72 eV with a full width at half maximum of 0.70 eV when excited above 3.5 eV, whereas it progressively empties on the high energy side when excited below 3.5 eV. Moreover, the lifetime falls in the ns timescale and decreases on increasing the emission energy. These features are due to the exceptionally broad inhomogeneous distribution of the emitting centres peculiar to the silica nanoparticles. © 2010 Elsevier B.V. All rights res…
Resonance Raman of oxygen dangling bonds in amorphous silicon dioxide
2016
We investigate the origin of a resonance Raman band induced by ionizing radiation in amorphous silicon dioxide (silica glass), which can be detected under ultraviolet laser excitation. A silica sample, rich of oxygen-excess related defects, was prepared by treating some length of a pure-silica-core multimode fiber in an O2 atmosphere (at high temperature and pressure) and by irradiating it with X-rays at 10 MGy(SiO2) dose. A micro-Raman study revealed a gaussian band peaking at 896 cm−1 with a full width at half maximum of 32 cm−1, which could be detected by exciting the sample with the 325-nm line of a HeCd laser. This spectral feature is absent in the Raman spectra performed with the 442-…